Baltimore City · 21224

2426 FLEET ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$314,700
Land use
Residential (R)
Year built
1915
Last sale
Jun 17, 2022

Assessment

OwnerGERRY, MICHAEL BRANDON
Land useResidential (R)
Total assessment$314,700 (cycle 2026)
Last saleJun 17, 2022 — $319,000
Year built1915
ZoningR-8
Vacant

Permits

16
TypeDescriptionCostIssued
USE2021USE AS A SINGLE FAMILY DWELLING Dec 3, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-77082:SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.) Original Permit Description:(COM2019-77082) SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.Dec 1, 2021
COM2021 REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-56607:INSTALL (20) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.) Original Permit Description:(COM2021-56607) INSTALL (20) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.Oct 28, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-87360:INSTALL (13) # PLUMBING FIXTURES, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE.) Original Permit Description:(COM2019-87360) INSTALL (13) # PLUMBING FIXTURES, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE.Oct 12, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2020-50155:INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 200 CFM EXHAUST SYSTEMS , (1) 60000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.) Original Permit Description:(COM2020-50155) INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 200 CFM EXHAUST SYSTEMS , (1) 60000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.Sep 30, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-77082:SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.) Original Permit Description:(COM2019-77082) SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.Sep 14, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-77082:SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.) Original Permit Description:(COM2019-77082) SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.Jul 15, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-77082:SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.) Original Permit Description:(COM2019-77082) SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.May 27, 2021
COM2021AA CONV: Full Description Loaded as CommentApr 15, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-77082:SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.) Original Permit Description:(COM2019-77082) SCOPE OF WORK:--ADDITION--REAR SECOND FLOOR ADDITION TO AN EXISTING SINGLE FAMILY, TWO-STORY, ROW HOUSE. --EXTERIOR ALTERATIONS--A REAR DECK WILL BE CONSTRUCTED TO PROVIDE ACCESS TO THE PROPOSED ROOF-TOP DECK.--INTERIOR ALTERATIONS-- INTERIOR RENOVATION: THE NEW INTERIOR LAYOUT WILL CONSISTS OF A KITCHEN, DINING ROOM, LIVING ROOM, AND HALF BATH ON THE FIRST FLOOR; TWO BEDROOMS, TWO BATHROOMS, AND A LAUNDRY CLOSET ON THE SECOND FLOOR. --CATEGORY I DEMOLITION--CONSISTS OF THE REMOVAL OF THE REAR EXTERIOR WALL ON THE SECOND FLOOR TO ACCOMMODATE THE PROPOSED ADDITION AND THE REMOVAL OF ALL INTERIOR NON-LOAD BEARING PARTITIONS. THE STAIRCASE IS EXISTING TO REMAIN. THE PROPOSED SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL WOOD FLOOR JOISTS SPACED 16'' ON CENTER BEARING ON THE EXISTING LOAD BEARING WALLS BELOW. THE EXTERIOR LOAD-BEARING WALLS WILL BE CONSTRUCTED USING 2X6 NOMINAL WOOD STUDS SPACED 16'' ON CENTER. THE EXISTING ROOF JOISTS WILL REMAIN, AND THE PROPOSED ROOF ABOVE THE SECOND FLOOR ADDITION WILL BE CONSTRUCTED USING 2X10 NOMINAL ROOF JOISTS SPACED 24'' ON CENTER. THE PROPOSED REAR DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS SPACED 16'' ON CENTER AND SUPPORTED BY 2X12 NOMINAL PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 NOMINAL PRESSURE TREATED WOOD POSTS. THE PROPOSED EXTERIOR STAIRCASE WILL BE CONSTRUCTED USING 2X10 NOMINAL STAIR STRINGERS. THE ROOF DECK WILL BE CONSTRUCTED USING 2X10 NOMINAL PRESSURE TREATED WOOD DECK JOISTS PACED 16'' ON CENTER. THE JOISTS WILL BE SUPPORTED BY 2X12 PRESSURE TREATED WOOD JOIST BEAMS BEARING ON 6X6 PRESSURE TREATED WOOD POSTS. SEPARATE PERMITS WILL BE REQUIRED FOR MECHANICAL ELECTRICAL AND PLUMBING. ALL WORK TO BE DONE ACCORDING TO SUBMITTED DRAWINGS AND IN ACCORDANCE WITH ALL CURRENT BALTIMORE CITY BUILDING CODES.Mar 5, 2021
COM2021INSTALL (20) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.$500Mar 4, 2021
COM2020INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 200 CFM EXHAUST SYSTEMS , (1) 60000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.$3,500Jan 3, 2020
COM2019install (20) # branch circuits/feeders , (1) 100 amps electric service up to 600v (#amps) as per code.$5,400Dec 11, 2019
COM2019install (13) # plumbing fixtures, (1) 30000 btu fuel-burning equip, (1) 90000 btu fuel-burning equip, (1) 90000 btu fuel-burning equip, (1) # water service pipe (reconstruction), (1) # sanitary connection (reconstruction0 as per code.$20,000Dec 11, 2019
COM2019scope of work:--addition--rear second floor addition to an existing single family, two-story, row house. --exterior alterations--a rear deck will be constructed to provide access to the proposed roof-top deck.--interior alterations-- interior renovation: the new interior layout will consists of a kitchen, dining room, living room, and half bath on the first floor; two bedrooms, two bathrooms, and a laundry closet on the second floor. --category i demolition--consists of the removal of the rear exterior wall on the second floor to accommodate the proposed addition and the removal of all interior non-load bearing partitions. the staircase is existing to remain. the proposed second floor addition will be constructed using 2x10 nominal wood floor joists spaced 16" on center bearing on the existing load bearing walls below. the exterior load-bearing walls will be constructed using 2x6 nominal wood studs spaced 16" on center. the existing roof joists will remain, and the proposed roof above the second floor addition will be constructed using 2x10 nominal roof joists spaced 24" on center. the proposed rear deck will be constructed using 2x10 nominal pressure treated wood deck joists spaced 16" on center and supported by 2x12 nominal pressure treated wood joist beams bearing on 6x6 nominal pressure treated wood posts. the proposed exterior staircase will be constructed using 2x10 nominal stair stringers. the roof deck will be constructed using 2x10 nominal pressure treated wood deck joists paced 16" on center. the joists will be supported by 2x12 pressure treated wood joist beams bearing on 6x6 pressure treated wood posts. separate permits will be required for mechanical electrical and plumbing. all work to be done according to submitted drawings and in accordance with all current baltimore city building codes.$60,000Nov 27, 2019
COM2019scope of work: interior alterations to include: interior demolition (category i): removing interior fixtures, fittings, finishes, non-structural walls and removal of all associated debris. all work will be done according to baltimore city code. demo only, separate permit will be pulled for interior renovations.$7,000Oct 24, 2019

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.