Assessment
| Owner | CASEY, CONOR |
|---|---|
| Land use | Residential (R) |
| Total assessment | $497,300 (cycle 2026) |
| Last sale | Jun 17, 2022 |
| Year built | 1915 |
| Zoning | R-8 |
| Vacant | — |
Permits
11| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2023 | USE AS A SINGLE FAMILY DWELLING. | — | May 5, 2023 |
| COM2022 | Extend Original Permit.(original permit:COM2021-75990:INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 90 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.) Original Permit Description:(COM2021-75990) INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 90 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE. | — | Feb 25, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2021-66637:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, & REMOVAL OF DEBRIS AND EQUIP. REMOVE FIRST AND SECOND FLOOR REAR WALL. NEW FIRST FLOOR REAR ADDITION. (12’-0'' X 6’), NEW SECOND FLOOR ADDITION. (12’-0'' X 16’-6”) & NEW ROOF TOP DECK. (12'-0''X 16'-0'') NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR BASEMENT, 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS, NEW EXTERIOR DOORS(3), NEW WINDOWS, NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL DECK WORK WILL MAINTAIN PROPER SETBACKS AND WORK WITHIN PRIVATE PROPERTY LINES)) Original Permit Description:(COM2021-66637) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, & REMOVAL OF DEBRIS AND EQUIP. REMOVE FIRST AND SECOND FLOOR REAR WALL. NEW FIRST FLOOR REAR ADDITION. (12’-0'' X 6’), NEW SECOND FLOOR ADDITION. (12’-0'' X 16’-6”) & NEW ROOF TOP DECK. (12'-0''X 16'-0'') NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR BASEMENT, 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS, NEW EXTERIOR DOORS(3), NEW WINDOWS, NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL DECK WORK WILL MAINTAIN PROPER SETBACKS AND WORK WITHIN PRIVATE PROPERTY LINES) | — | Feb 11, 2022 |
| COM2022 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-64695:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE.) Original Permit Description:(COM2021-64695) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | — | Jan 25, 2022 |
| COM2021 | Extend Original Permit.(original permit:COM2021-58472:INSTALL (13) # SANITARY CONNECTION (RECONSTRUCTION0, (2) 140000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-58472) INSTALL (13) # SANITARY CONNECTION (RECONSTRUCTION0, (2) 140000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Sep 23, 2021 |
| COM2021 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 90 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE. | $7,800 | Aug 25, 2021 |
| COM2021 | SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, & REMOVAL OF DEBRIS AND EQUIP. REMOVE FIRST AND SECOND FLOOR REAR WALL. NEW FIRST FLOOR REAR ADDITION. (12’-0'' X 6’), NEW SECOND FLOOR ADDITION. (12’-0'' X 16’-6”) & NEW ROOF TOP DECK. (12'-0''X 16'-0'') NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR BASEMENT, 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS, NEW EXTERIOR DOORS(3), NEW WINDOWS, NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL DECK WORK WILL MAINTAIN PROPER SETBACKS AND WORK WITHIN PRIVATE PROPERTY LINES) | $80,000 | Jun 16, 2021 |
| COM2021 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | $5,000 | May 13, 2021 |
| COM2021 | INSTALL (13) # SANITARY CONNECTION (RECONSTRUCTION0, (2) 140000 BTU FUEL-BURNING EQUIP AS PER CODE. | $6,000 | Mar 22, 2021 |
| COM2021 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: UNDERPINNING OF EXISTING BASEMENT AREA 40’-2''X 11'-4'' BASEMENT. EXISTING HEIGHT IS 6’-2'' AND NEW HEIGHT SHALL BE 7'-7''. “UNDERPINNING OF FOUNDATION WALLS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION'' ALL WORK SHALL BE IN ACCORDANCE WITH BALTIMORE CITY BUILDING CODES AND PER SUBMITTED PLANS. | $9,000 | Mar 1, 2021 |
| BMZ2021 | construct a two-story rear addition and rooftop deck. | — | Feb 10, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-CCE Building Permit ComplaintJul 9, 2026 · 90 m · 619 S LINWOOD AVE
- violation: HCD-CCE Building Permit ComplaintJul 9, 2026 · 94 m · 617 S LINWOOD AVE
- permit: BRCMJul 9, 2026 · 146 m · 815 S CURLEY ST
- violation: HCD-CCE Building Permit ComplaintJul 8, 2026 · 98 m · 615 S LINWOOD AVE
- permit: BRCMJul 7, 2026 · 102 m · 620 S POTOMAC ST
- violation: HCD-Sanitation PropertyJul 6, 2026 · 94 m · 701 S POTOMAC ST
- violation: HCD-Sanitation PropertyJul 6, 2026 · 144 m · 607 S STREEPER ST
- violation: 13 5-4Jul 2, 2026 · 119 m · 623 S STREEPER ST
- violation: PM 305.2.2Jun 26, 2026 · 65 m · 702 S LINWOOD AVE
- violation: PM 305.2.2Jun 26, 2026 · 149 m · 645 S KENWOOD AVE