Baltimore City · 21201

12 N EUTAW ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$67,578,867
Land use
Commercial (C)
Year built
1915
Last sale
Jan 20, 2004

This owner holds 2 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerMARYLAND STADIUM AUTHORITY
Land useCommercial (C)
Total assessment$67,578,867 (cycle 2026)
Last saleJan 20, 2004
Year built1915
ZoningC-5DC
Vacant

Permits

17
TypeDescriptionCostIssued
BCCMD/F Full Color LED Blade Sign Display Scope of work consists of the removal and replacement of one (1) existing double-faced blade sign with one (1) new double-faced digital LED blade display at the Hippodrome Theatre located at 12 N. Eutaw Street, Baltimore, MD 21201. The proposed sign cabinet will measure approximately 1’-8 7/8” wide x 6’-3 1/2” high x 1’-0 3/8” deep, for a total display area of approximately 10.94 square feet. Work includes installation of: • One (1) double-faced 6.67mm full-color LED digital blade display cabinet • Twelve (12) LED display cabinets total (six [6] cabinets per side) • Four (4) vertical Unistrut support channels • Fourteen (14) horizontal steel channel struts • One (1) NEMA 3R enclosure for surge suppression equipment • Associated power, data, and signal cabling connections • The existing steel mounting arms, mounting plates, conduit, and disconnect switch will remain and be reused where structurally suitable. Existing electrical box at the top of the sign will be removed and replaced with a new NEMA enclosure to accommodate the power requirements of the proposed digital display. Electrical scope includes providing one (1) dedicated 20AMP / 120V circuit for the blade sign and one (1) dedicated 20AMP / 120V circuit for head-end equipment. Maximum power consumption for the display is 599.04 watts at 120 volts with a maximum draw of 9.96 amps. All installation work shall be completed in accordance with manufacturer specifications, NEC requirements, and all applicable local building and electrical codes. As per plans as per code.$40,000Jun 22, 2026
BCCMLED Displays (Retro-fit into Marquee)Scope of Work: Remove existing marquee sign faces and track lettering from two (2) existing double-face marquee cabinets located at the Hippodrome Theatre, 12 N. Eutaw Street, Baltimore, MD. Retrofit existing marquee structures with new digital LED display systems while maintaining and reusing the existing perimeter bulb border cabinets, support framing, hanging rods, attachment plates, and select structural components. Install: • Two (2) new outdoor-rated 6.67mm SMD LED digital marquee displays • Each marquee display measures approximately 20’-5 11/16” W x 3’-1 13/16” H • Total display area per side: approximately 64.6 sq. ft. • Total combined display area: approximately 129.2 sq. ft. Digital Display Components: • Twelve (12) LED display cabinets total o Six (6) LED cabinets per marquee • Integrated steel Unistrut support framing: o Four (4) horizontal Unistruts per marquee o Six (6) vertical Unistruts per marquee • Ten (10) aluminum mounting angles total o Five (5) mounting angles per marquee • Aluminum filler panels painted satin/matte black to infill perimeter gaps around displays Electrical Work Includes: • Installation of two (2) NEMA enclosures for surge suppression equipment • Installation of required disconnect switches and liquid-tight conduit • Connection to owner-provided 120V power circuits • Total electrical load: 6,830 watts / 57.42 amps maximum • Five (5) dedicated 20A / 120V circuits for displays • One (1) additional 20A / 120V circuit for head-end equipment Low Voltage/Data: • Install CAT6 signal/data cabling between IDF room and both marquee displays • Install required digital display control equipment and media player components Exisiting conditions:• Existing marquee cabinets, perimeter bulb lighting, hanging rods, attachment plates, and primary structural framing to remain and be reused where noted. • No expansion of existing sign footprint. • No changes to building structure beyond attachment of retrofit mounting components to existing marquee framing. Approximate Weight: • Left marquee retrofit assembly: 480 lbs. • Right marquee retrofit assembly: 480 lbs. As per plans as per code$40,000Jun 22, 2026
BCCMSubmittal of Ansul Pre Engineered Fire Suppression System to obtain a permit for final testing with the Fire Marshal.$1,982Nov 20, 2025
BCCMCONSTRUCTION OF STRUCTURAL ELEMENTS TO INCLUDE: the infill of an existing window and construction of three steel columns. The columns have HSS stubs through an existing exterior wall to support a future marquee. The marquee will be submitted under a separate permit. The existing front facade will remain., AND ARCHITECTURAL FINISHES REQUIRED FOR INSTALLATION OF NEW MARQUEE AT THE FAYETTE STREET ENTRANCE. THE MARQUEE WILL BE SUBMITTED UNDER SEPARATE SIGNAGE PERMIT BY CONTRACTOR.. AS PER PLANS AS PER CODE NO NEW MP WORK INCLUDED IN SCOPE, EXCEPT FOR RELOCATION OF EXISTING DEVICES. NO INCREASE IN AREA AND NO CHANGE IN OCCUPANCY, USE, OR EGRESS. A LICENSED ELECTRICAL PROFESSIONAL IS REQUIRED BEFORE ANY DEVICES CAN BE RELOCATED AS PERTIAL WORK FOR THIS PERMIT.$200,000Jul 10, 2025
COM2023AMEND PERMIT #COM2020-03129, PLAN #2020-2484 ISSUED ON 11/10/21 TO INCORPORATE THE RELOCATION OF A BOX OFFICE, AN EXTERIOR ATTIC ACCESS STAIR, THE ADDITION OF SECONDARY STRUCTURAL MEMBERS TO SUPPORT THEATRICAL RIGGING, 2 INTERIOR MASONRY WALL OPENINGS, MEP REVISIONS TO INCORPORATE LULA LIFT AND USE OF ATTIC FOR THEATRICAL RIGGING AS PER PLANS AS PER CODE. LOW VOLTAGE CONTRACTOR SYSTEM COM- LICENSE NUMBER 02176473 EXP 04/30/2024$13,000,000Jan 22, 2024
COM2023FURNISH AND INSTALL FIRE ALARM SYSTEM PER CODE AS SHOWN ON THE PLANS$80,000Nov 7, 2023
USE2023USE BASEMENT PORTION OF BUILDING AS OFFICES. Jun 21, 2023
COM2023ADD 6 AND RELOCATE 87 SPRINKLER HEADS FOR REMODELING AS PER PLANS AS PER CODE.$83,000May 12, 2023
COM2022INSTALL A NEW WET PIPE SPRINKLER SYSTEM (89 HEADS) WITHIN ATTIC AREA AS PER PLANS AS PER CODE.$20,000Mar 3, 2023
COM2022FURNISH AND INSTALL FIRE ALARM SYSTEM AS PER PLANS AS PER CODE. $80,000Nov 1, 2022
COM2022AMEND PERMIT #COM2020-03129, PLAN #2020-2484 ISSUED 1/22/2021 FOR THE RENOVATION OF THE INTERIOR OF THE M&T PAVILION AT THE FMPAC, RENOVATION WILL INCLUDE NEW BALCONIES, AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER SYSTEM. $13,000,000Oct 6, 2022
COM2022INSTALL WET PIPE SPRINKLER SYSTEM (173 HEADS) AS PER PLANS AS PER CODE.$82,000Aug 12, 2022
COM2021UNDERPINNING AS PER PLANS AS PER CODE.$60,000Jan 26, 2022
COM2020RENOVATION OF THE INTERIOR OF THE M&T PAVILION AT THE FMPAC, RENOVATION WILL INCLUDE NEW BALCONIES AND RESTORATION OF HISTORIC INTERIOR FINISHES AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEMS.THE UNDERPINING WORK IS NOT UNDER THIS PERMIT. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEMS. THE UNDERPINING PERMIT WIL BE FILES SEPERATLY.$13,000,000Dec 29, 2020
COM2019exterior facade remediation to the hippodrome theatre to include replacement of missing or damaged brick, power washing and replacement of sealants. $30,000Jun 3, 2019
COM2019amend permit: add electrical contractor . extend original permit.(original permit:com2019-50715:scope of work: interior alternations (289sq.ft): interior demolition (category i): removing & replacing section of drywall ceiling & insulation (wet) *insulation will be at least r20 in walls and r49 in the ceilings, painting after repairs. small vestibule area has water damage. no alterations being made, all work will be done according to baltimore city code and per submitted sketch. ) original permit description:(com2019-50715) scope of work: interior alternations (289sq.ft): interior demolition (category i): removing & replacing section of drywall ceiling & insulation (wet) *insulation will be at least r20 in walls and r49 in the ceilings, painting after repairs. small vestibule area has water damage. no alterations being made, all work will be done according to baltimore city code and per submitted sketch. Feb 7, 2019
COM2019scope of work: interior alternations (289sq.ft): interior demolition (category i): removing & replacing section of drywall ceiling & insulation (wet) *insulation will be at least r20 in walls and r49 in the ceilings, painting after repairs. small vestibule area has water damage. no alterations being made, all work will be done according to baltimore city code and per submitted sketch. $2,000Jan 11, 2019

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;