Baltimore City · 21201
16 S EUTAW ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $8,542,700
- Land use
- Exempt Commercial (EC)
- Year built
- 1890
- Last sale
- Jan 3, 1991
Assessment
| Owner | UNIVERSITY PHYSICIANS, INC. |
|---|---|
| Land use | Exempt Commercial (EC) |
| Total assessment | $8,542,700 (cycle 2026) |
| Last sale | Jan 3, 1991 — $1,432,773 |
| Year built | 1890 |
| Zoning | C-5DC |
| Vacant | — |
Permits
10| Type | Description | Cost | Issued |
|---|---|---|---|
| BCCM | BFPE will relocate a total of eight sprinkler heads within the approximately 730 sq. ft. doctor’s office to provide proper coverage. | $7,040 | Dec 1, 2025 |
| BCCM | SCOPE OF WORK: ------- LEVEL II INTERIOR ALTERATIONS -------- Renovate existing space into Lactation suites per attached drawings. AS PER PLANS AND CODE. | $60,000 | Sep 2, 2025 |
| COM2023 | PROVIDE NEW PIPING AND FITTINGS TO THE EXISTING JAMES FRENKIL BUILDING FIRE SPRINKLER RISER ROOM, TO MEET THE REQUIREMENTS OF NFPA-13. WE ARE TO DEMOLISH THE EXISTING FDC AND FIRE PUMP TEST HEADER AND REINSTALL NEW 6'' MAINS WITH NEW 6'' X 2.5'' TEST HEADER AND FDC. THE LARGEST PIPE TO BE INSTALLED IS 6'' SCHEDULE 40 BLACK AS PER PLANS AS PER CODE. | $16,119 | Jan 30, 2024 |
| USE2021 | USE 5TH FLOOR AS OUTPATIENT SERVICE FOR THE DEPARTMENT OF OTORHINOLARYNGOLOGY 9HEAD & NECK SURGERY). | — | May 7, 2021 |
| COM2021 | INSTALL (50) # LOW VOLTAGE AS PER CODE. | $5,000 | Mar 19, 2021 |
| COM2020 | MODIFY THE EXISTING FIRE SPRINKLER SYSTEM (ADD 5 AND RELOCATE 13 HEADS) TO ACCOMMODATE THE TENANT MODIFICATIONS BEING MADE TO THE 5TH FLOOR AND MINOR INTERIOR RENOVATIONS ON THE 4TH FLOOR AS PER PLANS AS PER CODE. | $2,250 | Mar 4, 2021 |
| COM2020 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR .(ORIGINAL PERMIT:COM2020-02202:(FRENKIL OTO) - INTERIOR TENANT FIT OUT ON THE FIFTH FLOOR AND MINOR INTERIOR RENOVATION ON THE FOURTH FLOOR OF THE FRENKIL BUILDING AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS.) Original Permit Description:(COM2020-02202) (FRENKIL OTO) - INTERIOR TENANT FIT OUT ON THE FIFTH FLOOR AND MINOR INTERIOR RENOVATION ON THE FOURTH FLOOR OF THE FRENKIL BUILDING AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS. | — | Nov 25, 2020 |
| COM2020 | (FRENKIL OTO) - INTERIOR TENANT FIT OUT ON THE FIFTH FLOOR AND MINOR INTERIOR RENOVATION ON THE FOURTH FLOOR OF THE FRENKIL BUILDING AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS. | $550,000 | Nov 16, 2020 |
| COM2019 | install (6) # branch circuits/feeders as per code. | $9,000 | Jul 9, 2019 |
| COM2019 | install 6 outside air fans at mechanical rooms for each of the 6 floors as per plans as per code. | $71,495 | Jun 26, 2019 |
Violations
1| Kind | Category | Status | Date |
|---|---|---|---|
| service_request | SW-Dirty Alley | Closed | Feb 19, 2026 |
Inspections
0No inspections on record.
Nearby recent activity
- violation: SW-Dirty AlleyJun 29, 2026 · 52 m
- violation: SW-Dirty AlleyJun 26, 2026 · 116 m
- violation: SW-Dirty AlleyJun 25, 2026 · 52 m
- violation: SW-Dirty AlleyJun 22, 2026 · 148 m
- violation: HCD-Sanitation PropertyJun 18, 2026 · 52 m
- permit: BRCMJun 17, 2026 · 137 m · 22 S HOWARD ST
- violation: HCD-Sanitation PropertyJun 11, 2026 · 77 m · 15 S EUTAW ST
- violation: SW-Dirty AlleyJun 7, 2026 · 61 m
- permit: BUSEMay 7, 2026 · 141 m · 311 W BALTIMORE ST
- violation: BC 123.8.1May 1, 2026 · 59 m · 34 S EUTAW ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.