Baltimore City · 21224

113 N DECKER AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$289,133
Land use
Residential (R)
Year built
1920
Last sale
Nov 13, 2023

Assessment

OwnerWOLFE, SHELLY E.
Land useResidential (R)
Total assessment$289,133 (cycle 2026)
Last saleNov 13, 2023
Year built1920
ZoningR-8
Vacant

Permits

12
TypeDescriptionCostIssued
USE2022USE AS A SINGLE FAMILY DWELLINGMar 25, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-62641:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) ) Original Permit Description:(COM2021-62641) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) Mar 23, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-69971:INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-69971) INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.Mar 16, 2022
COM2022INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP, (3) 35 CFM EXHAUST SYSTEMS AS PER CODE.$5,000Mar 2, 2022
COM2022 Extend Original Permit.(original permit:COM2021-75677:INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.) Original Permit Description:(COM2021-75677) INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.Feb 26, 2022
COM2022 Extend Original Permit.(original permit:COM2021-72757:INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2021-72757) INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE.Jan 27, 2022
COM2021INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$5,000Aug 23, 2021
COM2021INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE.$5,000Jul 26, 2021
COM2021INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.$8,500Jul 2, 2021
COM2021SCOPE OF WORK:----INTEIRIOR ALTERATIONS---UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. ALL WORK WILL BE DONE AS PER PLANS AND BALTIMORE CITY CODE$5,000Jun 15, 2021
COM2021REMOVE FORMSTONE, CLEAN AND REPOINT EXISTING BRICK PER BALTIMORE CITY CODE.$3,000May 17, 2021
COM2021INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) $80,000May 3, 2021

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;