Baltimore City · 21224
113 N DECKER AVE
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $289,133
- Land use
- Residential (R)
- Year built
- 1920
- Last sale
- Nov 13, 2023
Assessment
| Owner | WOLFE, SHELLY E. |
|---|---|
| Land use | Residential (R) |
| Total assessment | $289,133 (cycle 2026) |
| Last sale | Nov 13, 2023 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | — |
Permits
12| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2022 | USE AS A SINGLE FAMILY DWELLING | — | Mar 25, 2022 |
| COM2022 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-62641:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) ) Original Permit Description:(COM2021-62641) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) | — | Mar 23, 2022 |
| COM2022 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-69971:INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-69971) INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Mar 16, 2022 |
| COM2022 | INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP, (3) 35 CFM EXHAUST SYSTEMS AS PER CODE. | $5,000 | Mar 2, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2021-75677:INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.) Original Permit Description:(COM2021-75677) INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | — | Feb 26, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2021-72757:INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2021-72757) INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE. | — | Jan 27, 2022 |
| COM2021 | INSTALL (1) 70000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | $5,000 | Aug 23, 2021 |
| COM2021 | INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE. | $5,000 | Jul 26, 2021 |
| COM2021 | INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (13) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE. | $8,500 | Jul 2, 2021 |
| COM2021 | SCOPE OF WORK:----INTEIRIOR ALTERATIONS---UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. ALL WORK WILL BE DONE AS PER PLANS AND BALTIMORE CITY CODE | $5,000 | Jun 15, 2021 |
| COM2021 | REMOVE FORMSTONE, CLEAN AND REPOINT EXISTING BRICK PER BALTIMORE CITY CODE. | $3,000 | May 17, 2021 |
| COM2021 | INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING PARTIAL 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (17). NEW EXTERIOR WORK: REBUILD EXISTING 1ST FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR ADDITION (7'-9.5''X12'-2'') (85 SF), NEW 2ND FLOOR REAR DECK (10'X12'-2''), NEW EXTERIOR DOORS (3), WINDOWS (6). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (22'X12'-2'')(268 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND ADDITION CONSTRUCTION WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) | $80,000 | May 3, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 10, 2026 · 28 m · 104 N ELLWOOD AVE
- permit: BRCMJul 10, 2026 · 90 m · 20 N DECKER AVE
- violation: HCD-Vacant BuildingJul 9, 2026 · 146 m · 207 N ELLWOOD AVE
- violation: HCD-Vacant BuildingJul 9, 2026 · 146 m · 207 N ELLWOOD AVE
- violation: HCD-Vacant BuildingJul 9, 2026 · 149 m · 209 N ELLWOOD AVE
- violation: HCD-Sanitation PropertyJul 7, 2026 · 118 m · 3 N DECKER AVE
- violation: SW-Dirty AlleyJul 7, 2026 · 128 m · 202 N ELLWOOD AVE
- violation: HCD-Vacant BuildingJul 7, 2026 · 129 m · 209 N ELLWOOD AVE
- violation: SW-Dirty AlleyJul 6, 2026 · 88 m · 3104 E FAIRMOUNT AVE
- violation: SW-Dirty AlleyJul 6, 2026 · 130 m
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.