Assessment
| Owner | BALTIMORE EXCEL 01 LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $65,000 (cycle 2026) |
| Last sale | Apr 9, 2020 — $27,500 |
| Year built | 1913 |
| Zoning | R-8 |
| Vacant | — |
Permits
7| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2020 | USE AS A SINGLE-FAMILY DWELLING. | — | Mar 4, 2021 |
| COM2020 | AMENDMENT TO ACTIVE BUILDING PERMIT #COM2020-60495 TO INCLUDE THE ADDITIONAL SCOPE OF WORK: NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER PLANS. REPLACEMENT OF DAMAGED WOOD FRAMING WITH NEW WOOD JOISTS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED. THE REMAINING STRUCTURE WILL BE SECURED. NEW WOOD BOX STAIRS FROM BASEMENT TO 1ST FLOOR, FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AND FROM 2ND FLOOR TO 3RD FLOOR LEVELS, AT 8.25” MAX RISER HEIGHT AND 9” MIN TREAD DEPTH. EXTERIOR ALTERATIONS TO INCLUDE: NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 100’ IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. | $45,000 | Nov 17, 2020 |
| COM2020 | EXTEND: (ORIGINAL PERMIT:COM2020-60518:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (22) # BRANCH CIRCUITS/FEEDERS , (40) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2020-60518) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (22) # BRANCH CIRCUITS/FEEDERS , (40) # FIXTURES/DEVICES AS PER CODE. | — | Nov 12, 2020 |
| COM2020 | Extend Original Permit.(original permit:COM2020-60575:INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 70 CFM EXHAUST SYSTEMS , (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (10) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2020-60575) INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 70 CFM EXHAUST SYSTEMS , (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (10) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Nov 9, 2020 |
| COM2020 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 70 CFM EXHAUST SYSTEMS , (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (10) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE. | $6,000 | Apr 16, 2020 |
| COM2020 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (22) # BRANCH CIRCUITS/FEEDERS , (40) # FIXTURES/DEVICES AS PER CODE. | $10 | Apr 15, 2020 |
| COM2020 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY I): INTERIOR FRAMING NON STRUCTURAL (PERIMETER WALLS ONLY/NO NEW PARTITION WALLS TO BE BUILT), INSTALL NEW INSULATION (IF INSTALLED IN THE WALLS-R20/IF INSTALLED IN THE CEILINGS-R49), INSTALL NEW DRYWALL, INSTALL NEW HARDWOOD FLOORING, INSTALL NEW TILING, PAINTING, REPLACEMENT OF KITCHEN CABINETS, REPLACEMENT OF INTERIOR DOORS (IN THE SAME SIZE AND LOCATION), EXTERIOR ALTERATIONS TO INCLUDE: WINDOW REPLACEMENT SAME SIZE AND SAME LOCATION, INSTALLATION OF NEW RUBBER ROOF (NO STRUCTURAL ALTERATIONS TO BE DONE TO THE ROOF), EXTERIOR STUCCO/SIDING REPAIR, REPLACEMENT OF EXTERIOR DOORS SAME SIZE AND LOCATION AS EXISTING, ALL WORK WILL BE DONE AS PER BALTIMORE CITY CODE**** APPROVED WITH THE CONDITION PER PLANNING THAT ALL CODE AND REGULATORY REQUIREMENTS HAVE BEEN MET AND ALL DOOR, TRANSOM AND WINDOW REPLACEMENT ASSEMBLIES FIT WITHIN EXISTING OPENINGS AND COMPLEMENT CHARACTER OF EXISTING STRUCTURE. | $2,500 | Apr 15, 2020 |
Violations
2| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| citation | PM 306.6 | P | $50 | $0 | Dec 29, 2025 |
| citation | PM 306.1 | P | $50 | $0 | Dec 29, 2025 |
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 10, 2026 · 55 m · 1827 N BOND ST
- violation: 13 4-5A.2Jul 8, 2026 · 86 m · 1523 E NORTH AVE
- violation: HCD-Sanitation PropertyJul 8, 2026 · 117 m · 1738 N BOND ST
- violation: SW-HGWJul 7, 2026 · 95 m
- violation: SW-HGWJul 7, 2026 · 120 m · 1724 N BETHEL ST
- violation: SW-HGWJul 7, 2026 · 123 m · 1722 N BETHEL ST
- violation: SW-HGWJul 7, 2026 · 129 m · 1718 N BETHEL ST
- violation: SW-HGWJul 7, 2026 · 131 m
- violation: SW-HGWJul 7, 2026 · 134 m · 1714 N BETHEL ST
- violation: SW-HGWJul 7, 2026 · 137 m · 1712 N BETHEL ST