Permits

9
TypeDescriptionCostIssued
BUSECONTINUE TO USE AS SINGLE FAMILY DWELLING This property is in an Urban Renewal Plan Area and must follow URP guidelines. For more information visit, https://planning.baltimorecity.gov/planning-plans/urban-renewalFeb 25, 2026
COM2024 INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (15) # BRANCH CIRCUITS/FEEDERS, 25 LOW VOLTAGE AS PER CODE. Feb 12, 2025
COM2024REISSUANCE OF ORIGINAL PERMIT COM2023-87138 ISSUED ON 11/17/2023 - STRUCTURAL ALTERATIONS : INTERIOR WORK/REMOVE/REPLACE 1359 SQ FT: INTERIOR ALTERATIONS: FRAMING USING 2 X 4 @ 16" OC, DRYWALL, TRIM, INSULATION R-20 WALLS AND R-49 CEILINGS. INSTALL NEW STAIR CASE TREAD 10" RISE 7 3/4" WIDE 36" REMOVE AND REPLACE FLOOR JOISTS ( 2 X 10 @ 16" OC). .REMOVE AND REPLACE ROOF RAFTERS ( 2 X 10 @ 16"OC. REMOVE AND INSTALL 7 WINDOWS, 2 EXTERIOR DOORS. 7 INTERIOR DOORS SAME SIZE/LOCATION. GUTTERS AND DOWNSPOUNTS; PAINT EXTERIOR AS PER DRAWING /CODE. PLANS PREVIOUSLY APPROVED ON PERMIT COM2020-69943 ISSUED ON 07.15.2020********************AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH THE REGULATIONS ON PAGE 40 OF THE OLIVER URBAN RENEWAL PLAN. THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY. "ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. "$2,500Aug 21, 2024
COM2024INSTALL (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE. $5,500Aug 21, 2024
COM2024INSTALL (1) 60 CFM EXHAUST SYSTEMS , (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$6,500Aug 14, 2024
COM2023STRUCTURAL ALTERATIONS : INTERIOR WORK/REMOVE/REPLACE 1359 SQ FT: INTERIOR ALTERATIONS: FRAMING USING 2 X 4 @ 16'' OC, DRYWALL, TRIM, INSULATION R-20 WALLS AND R-49 CEILINGS. INSTALL NEW STAIR CASE TREAD 10'' RISE 7 3/4'' WIDE 36'' REMOVE AND REPLACE FLOOR JOISTS ( 2 X 10 @ 16'' OC). .REMOVE AND REPLACE ROOF RAFTERS ( 2 X 10 @ 16''OC. REMOVE AND INSTALL 7 WINDOWS, 2 EXTERIOR DOORS. 7 INTERIOR DOORS SAME SIZE/LOCATION. GUTTERS AND DOWNSPOUNTS; PAINT EXTERIOR AS PER DRAWING /CODE. PLANS PREVIOUSLY APPROVED ON PERMIT COM2020-69943 ISSUED ON 07.15.2020********************AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH THE REGULATIONS ON PAGE 40 OF THE OLIVER URBAN RENEWAL PLAN. THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY. ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. ''$2,500Nov 17, 2023
COM2022ORIGINAL COM2020-69943 - CATEGORY2: STRUCTURALALTERATIONS: INTERIOR WORK/REMOVE/REPLACE 1359 SQ FT: INTERIOR ALTERATIONS: FRAMING USING 2 X 4 @ 16'' OC, DRYWALL, TRIM, INSULATION R-20 WALLS AND R-49 CEILINGS. INSTALL NEW STAIR CASE TREAD 10'' RISE 7 3/4'' WIDE 36'' REMOVE AND REPLACE FLOOR JOISTS ( 2 X 10 @ 16'' OC). .REMOVE AND REPLACE ROOF RAFTERS ( 2 X 10 @ 16''OC. REMOVE AND INSTALL 7 WINDOWS, 2 EXTERIOR DOORS. 7 INTERIOR DOORS SAME SIZE/LOCATION. GUTTERS AND DOWNSPOUNTS; PAINT EXTERIOR AS PER DRAWING /CODE. PLANS PREVIOUSLY APPROVED ON PERMIT COM2020-69943 ISSUED ON 07.15.2020******** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT DOORS AND WINDOWS MUST COMPLY WITH REGULATIONS IN OLIVER URBAN RENEWAL PLAN PAGE 38 UNDER ''2. WINDOWS AND DOORS'' INCLUDING BUT NOT LIMITED TO THE FOLLOWING SECTIONS '' ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE.''$8,700Nov 25, 2022
COM2020CATEGORY2: STRUCTURALALTERATIONS: INTERIOR WORK/REMOVE/REPLACE 1359 SQ FT: INTERIOR ALTERATIONS: FRAMING USING 2 X 4 @ 16'' OC, DRYWALL, TRIM, INSULATION R-20 WALLS AND R-49 CEILINGS. INSTALL NEW STAIR CASE TREAD 10'' RISE 7 3/4'' WIDE 36'' REMOVE AND REPLACE FLOOR JOISTS ( 2 X 10 @ 16'' OC). .REMOVE AND REPLACE ROOF RAFTERS ( 2 X 10 @ 16''OC. REMOVE AND INSTALL 7 WINDOWS, 2 EXTERIOR DOORS. 7 INTERIOR DOORS SAME SIZE/LOCATION. GUTTERS AND DOWNSPOUNTS; PAINT EXTERIOR AS PER DRAWING /CODE.$8,500Jul 15, 2020
COM2020CATEGORY II - NON-STRUCTURAL DEMOLITION ONLY 983 SQ FT (INCLUDES THE REMOVAL OF PLASTER, DRYWALL, DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). THIS INCLUDES ALL OR PART OF CATEGORY I AND ALLOWS THE REMOVAL OF UP TO 1/3 OF LIKE STRUCTURAL MEMBERS ON THAT LEVEL. THE REMAINING STRUCTURE MUST BE SECURED. * EXAMPLE: THE REMOVAL OF 6 OF THE TOTAL 18 FLOOR JOISTS ON THE 2ND FL. OR THE REMOVAL OF 5 OF THE TOTAL 15 ROOF RAFTERS. $2,500Jun 24, 2020

Violations

0

No violations on record.

Inspections

0

No inspections on record.