Baltimore City · 21213
1739 E FEDERAL ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $71,667
- Land use
- Residential (R)
- Year built
- 1905
- Last sale
- Jul 26, 2022
Assessment
| Owner | BALTIMORE EXCEL 02 LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $71,667 (cycle 2026) |
| Last sale | Jul 26, 2022 — $23,000 |
| Year built | 1905 |
| Zoning | R-8 |
| Vacant | — |
Permits
5| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2021 | USE AS A SINGLE-FAMILY DWELLING. | — | Mar 26, 2022 |
| COM2022 | AS PER PLANNING: FENCING MUST COMPLY WITH URBAN RENEWAL PLAN FOR BROADWAY EAST PAGE 23 ''SCREENING (PRIVACY FENCING) IS PERMITTED AROUND BACK YARDS. IT MAY BE OPAQUE TO A MAXIMUM OF 48 INCHES. THERE MAY BE UP TO AN ADDITIONAL 24 INCHES OF FENCE IN A LATTICE OR PICKET STYLE.''***********AMENDMENT TO EXISTING PERMIT #COM2022-57433 TO INCLUDE: NEW STL CHAINLINK FENCE, @ 6’-0” MAX HEIGHT, APPROXIMATELY 75’-0” IN LENGTH, ALONG INSIDE OF PROPERTY LINE. NEW VINYL SIDING WAS INSTALLED UNDER, AND INCLUDED IN, EXISTING PERMIT #COM2022-57433. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE. | $3,000 | Mar 21, 2022 |
| COM2022 | AA CONV: Full Description Loaded as Comment | — | Feb 28, 2022 |
| COM2021 | AA CONV: Full Description Loaded as Comment | — | Oct 29, 2021 |
| COM2021 | SCOPE OF WORK — INTERIOR ALTERATIONS, TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). INSTALLATION OF NEW BEAMS AT NEW STAIR OPENINGS, AS PER PLANS. REPLACEMENT OF DAMAGED WOOD FRAMING, AS PER PLANS. CLOSURE OF EXISTING STAIR OPENINGS, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED, THE EXISTING JOIST FRAMING ARE TO REMAIN WHERE SHOWN. THE REMAINING STRUCTURE WILL BE SECURED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 36'' MIN WIDTH 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF 2 EXTERIOR DOORS AND 13 EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS. INSTALLATION OF VINYL SIDING IN PORTION OF THE REAR EXTERIOR. BROADWAY EAST - 3-2-21 APPROVED WITH THE CONDITION THAT ALL CODE AND REGULATORY REQUIREMENTS ARE MET. ALL WINDOW, TRANSOM AND DOOR REPLACEMENT ASSEMBLIES SHALL FIT WITHIN EXISTING STRUCTURAL OPENINGS AND COMPLEMENT CHARACTER OF EXISTING STRUCTURE. ELECTRICAL: INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AND REWIRE THROUGHOUT, (45) # FIXTURES/DEVICES INCLUDING OUTLETS, LIGHTS, SWITCHES, FIXTURES, SMOKE/CO DETECTORS AS PER CODE. MECHANICAL/PLUMBING/GAS: INSTALL (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 70 CFM EXHAUST SYSTEMS, (1) # ELECTRIC WATER HEATER, (1) # STORMWATER CONNECTION (RECONSTRUCTION), (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION), (6) # PLUMBING FIXTURES, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN 36'' MINIMUM WIDTH, 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) - BROADWAY EAST:3-2-21 APPROVED WITH THE CONDITION THAT ALL CODE AND REGULATORY REQUIREMENTS ARE MET. ALL WINDOW, TRANSOM AND DOOR REPLACEMENT ASSEMBLIES SHALL FIT WITHIN EXISTING STRUCTURAL OPENINGS AND COMPLEMENT CHARACTER OF EXISTING STRUCTURE. | $65,000 | Mar 3, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: SW-HGWJul 9, 2026 · 79 m · 1501 N REGESTER ST
- violation: HCD-Vacant BuildingJul 9, 2026 · 92 m · 1526 N DURHAM ST
- violation: HCD-Maintenance StructureJul 9, 2026 · 130 m · 1526 N WOLFE ST
- violation: HCD-Illegal DumpingJul 8, 2026 · 60 m · 1500 RUTLAND AVE
- violation: HCD-Illegal DumpingJul 8, 2026 · 81 m · 1736 E OLIVER ST
- violation: HCD-Sanitation PropertyJul 7, 2026 · 61 m · 1513 N REGESTER ST
- violation: SW-Dirty AlleyJul 7, 2026 · 82 m · 1746 E OLIVER ST
- violation: HCD-Vacant BuildingJul 7, 2026 · 86 m · 1724 E OLIVER ST
- violation: HCD-Sanitation PropertyJul 7, 2026 · 92 m · 1718 E OLIVER ST
- violation: HCD-Sanitation PropertyJul 7, 2026 · 141 m · 1510 N WOLFE ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;