Baltimore City · 21213

1720 E OLIVER ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$220,000
Land use
Residential (R)
Year built
1910
Last sale
Apr 10, 2024

This owner holds 4 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerBELIEVE BIG LLC
Land useResidential (R)
Total assessment$220,000 (cycle 2026)
Last saleApr 10, 2024 — $65,000
Year built1910
ZoningR-8
Vacant

Permits

8
TypeDescriptionCostIssued
BUSEThe Monumental Group-Use the premises for a residential care facility (assisted living) accommodating up to five residents. This use is contingent upon inspection and compliance with all applicable fire and building code regulations.Aug 27, 2025
USE2024USE AS A SINGLE-FAMILY DWELLING. Aug 7, 2024
COM2024INSTALL (4) 50 CFM EXHAUST SYSTEMS AS PER CODE.$500Jun 12, 2024
COM2024SCOPE OF WORK: ------- INTERIOR ALTERATIONS --------- TO INCLUDE CATEGORY 1 DEMO (200 SF) OF NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW INTERIOR WORK: FRAMING (800 SF) W/ STUD WALLS, NEW STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). ----- EXTERIOR ALTERATIONS ------ NEW LVL BEAMS TO SUPPORT EXISTING ROOF, DOORS (19). AS PER PLANS, AS PER CODE. $25,000May 29, 2024
COM2024INSTALL (12) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE.$1,000Apr 18, 2024
COM2024INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$7,750Apr 18, 2024
COM2024INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$5,000Apr 15, 2024
COM2024SCOPE OF WORK: ------ INTERIOR/EXTERIOR ALTERATIONS ------DEMO WORK: CATEGORY 1 DEMO (500 SF) OF NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW INTERIOR WORK: NEW COSMETIC RENOVATION THROUGHOUT (1,200 SF). NEW DRYWALL, TRIM, PAINT, FLOORING,CABINETS AND COUNTERTOPS. NEW INSULATION (R-20 WALLS, R-49 ROOF). DOORS (16). NO FRAMING, NO STRUCTURAL ROOF REPAIRS. NEW EXTERIOR WORK: NEW EXTERIOR DOORS (2), WINDOWS (8). *WINDOWS AND DOORS IN THE SAME LOCATION. AS PER CODE.*************** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS SHALL COMPLY WITH REGULATIONS ON PAGE 21 OF THE BROADWAY EAST URBAN RENEWAL PLAN AND THE SIZE OF THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED.''$25,000Feb 20, 2024

Violations

13
KindCategoryStatusFineBalanceDate
service_requestHCD-Sanitation PropertyClosedApr 15, 2026
citationPM 305.1P$50$0Apr 13, 2026
citationPM 306.2P$50$0Apr 13, 2026
service_requestHCD-Sanitation PropertyClosedApr 6, 2026
citationPM 305.1P$50$0Mar 20, 2026
citationPM 306.2P$50$0Mar 20, 2026
service_requestHCD-Sanitation PropertyClosedMar 16, 2026
service_requestHCD-Sanitation PropertyClosedMar 12, 2026
citationPM 306.4P$50$0Mar 4, 2026
citationPM 305.1P$50$0Mar 4, 2026
service_requestHCD-Sanitation PropertyClosedMar 2, 2026
service_requestHCD-Sanitation PropertyClosedFeb 23, 2026
citationPM 305.2.2P$50$0Sep 22, 2025

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.