Baltimore City · 21213

1631 E OLIVER ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$92,667
Land use
Residential (R)
Year built
1914
Last sale
Dec 14, 2022

This owner holds 2 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerABLOPE HOMES, LLC
Land useResidential (R)
Total assessment$92,667 (cycle 2026)
Last saleDec 14, 2022 — $48,000
Year built1914
ZoningR-8
Vacant

Permits

5
TypeDescriptionCostIssued
BUSEuse as a Single family dwellingMay 24, 2026
COM2024SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. " THIS IS BASICALLY A SHELL. THE ROOF AND INTERIOR WALLS HAVE COLLAPSED DUE TO WEATHER AND NEGLECT. FRAMING TO CREATE NEW PARTITION WALLS,FRAME EXTERIOR WALLS, INSTALLATION OF NEW DRYWALL, INSTALLATION OF NEW INSULATION IN THE WALLS (R21 WALLS/R49CEILINGS), 6 FEET WOOD FENCING IN THE REAR,REAR BUMP OUT FOUNDATION 45INSTALLATION OF NEW WINDOWS, DEMO WALLS,INTERIOR DOORS AND EXTERIOR DOORS (WINDOWS AND DOORS, INSTALLATION OF NEW FINISHES HARDWARE,INSTALL CONCRETE IN THE REAR,MASONRY WORK,FRENCH DRAIN TILE ,OF THE HOUSE,ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE. SEPARATE PERMIT IS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING)Jan 29, 2025
COM2024INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 72000 BTU FUEL-BURNING EQUIP(FURNACE), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$1,000Jan 14, 2025
COM2024INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) # ELECTRIC WATER HEATER, (2) 120000 BTU FUEL-BURNING EQUIP, (12) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST AS PER CODE.$5,200Dec 10, 2024
COM2024APWC; RECEIVED ON 4/3 DUE TO SYSTEM ERROR.REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH THE REGULATIONS ON PAGE 40 OF THE OLIVER URBAN RENEWAL PLAN. THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY. ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. '' THIS IS BASICALLY A SHELL. THE ROOF AND INTERIOR WALLS HAVE COLLAPSED DUE TO WEATHER AND NEGLECT. FRAMING TO CREATE NEW PARTITION WALLS,FRAME EXTERIOR WALLS, INSTALLATION OF NEW DRYWALL, INSTALLATION OF NEW INSULATION IN THE WALLS (R21 WALLS/R49CEILINGS), 6 FEET WOOD FENCING IN THE REAR,REAR BUMP OUT FOUNDATION 45INSTALLATION OF NEW WINDOWS, DEMO WALLS,INTERIOR DOORS AND EXTERIOR DOORS (WINDOWS AND DOORS, INSTALLATION OF NEW FINISHES HARDWARE,INSTALL CONCRETE IN THE REAR,MASONRY WORK,FRENCH DRAIN TILE ,OF THE HOUSE,ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE. SEPARATE PERMIT IS REQUIRED FOR MECHANICAL, ELECTRICAL, AND PLUMBING$45,000Jul 1, 2024

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;