Baltimore City · 21213

2003 E LAFAYETTE AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$200,000
Land use
Residential (R)
Year built
1903
Last sale
Sep 8, 2025

This owner holds 2 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerJ&K GROWTH PROPERTIES LLC
Land useResidential (R)
Total assessment$200,000 (cycle 2026)
Last saleSep 8, 2025 — $90,000
Year built1903
ZoningR-8
Vacant

Permits

13
TypeDescriptionCostIssued
BUSEUSE AS A SINGLE FAMILY DWELLING This property is in a Urban Renewal Plan Area and must follow URP guidelines. For more information visit, https://planning.baltimorecity.gov/planning-plans/urban-renewalinformationJan 28, 2026
BRCMSCOPE OF WORK: ------ INTERIOR/EXTERIOR ALTERATIONS ---------: INTERIOR DEMOLITION (CATEGORY 2): RENOVATE KITCHEN, NEW HARDWOOD FLOORING, INSTALL NEW DRYWALL, PAINT THE ENTIRE HOUSE, INSTALL NEW 6 WINDOWS SAME SIZE AND PLACE, REPLACE 2 EXTERIOR DOORS SAME SIZE AND PLACE, FURRING ON PERIMETER WALLS AND BULK HEADS (FRAMING USING 2X4 NO NEW PARTITION WALLS WILL BE BUILT), INSTALL R49 AND R21 INSULATION IN CEILING AND WALLS. ------EXTERIOR ALTERATIONS ------ INSTALL NEW RUBBER ROOF (NO STRUCTURAL ALTERNATIONS TO THE ROOF). Replace rear fence planks same size and location 23 ft 1x6x6 Repair front and rear steps same size and location and install handrails ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE. *******SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK ******* Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance.$24,050Jan 23, 2026
BRCM200 AMP SERVICE 15 CIRCUITS 9 PLUMBING FIXTURES WATER AND WASTE HEAT PUMP DUCT AS NEEDED$5,100Dec 20, 2025
BRCMDEMOLITION ONLY CATEGORY 1$2,470Sep 23, 2025
COM2024AMEND PERMIT: CHANGE PLUMBER CONTRACTOR . EXTEND ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2024-51490:INSTALL (8) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE.) Original Permit Description:(COM2024-51490) INSTALL (8) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE.Sep 29, 2024
COM2024NTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: 1 INTERIOR DEMOLITION (CATEGORY 3). 2 REMOVE AND REPLACE EXISTING ROOF, SHEATHING AND ROOF JOISTS. INSTALL NEW 2X10X16 JOISTS 16” ON CENTER, INSTALL NEW 1/2” OSB SHEATHING, INSTAL NEW RUBBER ROOF SYSTEM. 3 INSTALL NEW 2X10X16 JOISTS 16” ON CENTER FOR FIRST AND SECOND FLOOR, INSTALL 3/4 IN O TONGUE & GROOVE SHEATHING. 4 INSTALL NEW STAIRCASE SYSTEMS 5 INSTALL NEW WALL/CEILING FRAMING AND DRYWALL, 6 INSTALL NEW FLOORING 7 REPLACE 7 WINDOWS SAME SIZE AND LOCATION. 8 REPLACE 3 EXTERIOR DOORS SAME SIZE AND LOCATION. 9 ALL WORK WILL DONE ACCORDING TO BALTIMORE CITY CODES *****PER PLANNING DEPT: REPLACEMENT WINDOWS SHALL COMPLY WITH REGULATIONS ON PAGE 21 OF THE BROADWAY EAST URBAN RENEWAL PLAN AND THE SIZE OF THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY "ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED."****$20,000Sep 4, 2024
COM2024INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (20) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$4,500May 16, 2024
COM2024INSTALL (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (4) 600 CFM EXHAUST SYSTEMS AS PER CODE.$8,800Feb 13, 2024
COM2024INSTALL (8) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE.$1,000Jan 18, 2024
COM2023INSTALL (20) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.$4,000Feb 1, 2023
COM2022NTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: 1 INTERIOR DEMOLITION (CATEGORY 3). 2 REMOVE AND REPLACE EXISTING ROOF, SHEATHING AND ROOF JOISTS. INSTALL NEW 2X10X16 JOISTS 16” ON CENTER, INSTALL NEW 1/2” OSB SHEATHING, INSTAL NEW RUBBER ROOF SYSTEM. 3 INSTALL NEW 2X10X16 JOISTS 16” ON CENTER FOR FIRST AND SECOND FLOOR, INSTALL 3/4 IN O TONGUE & GROOVE SHEATHING. 4 INSTALL NEW STAIRCASE SYSTEMS 5 INSTALL NEW WALL/CEILING FRAMING AND DRYWALL, 6 INSTALL NEW FLOORING 7 REPLACE 7 WINDOWS SAME SIZE AND LOCATION. 8 REPLACE 3 EXTERIOR DOORS SAME SIZE AND LOCATION. 9 ALL WORK WILL DONE ACCORDING TO BALTIMORE CITY CODES AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. A BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) SEPERATE PERMITS FOR EMP WORK. LICENSED CONTRACTOR IN MARYLAND MUST WORK ON THIS PROPOSAL. *** PER PLANNING DEPT: REPLACEMENT WINDOWS AND DOORS MUST COMPLY WITH BROADWAY EAST URBAN RENEWAL PLAN REGULATIONS ON PAGE 21 ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. ''$20,000Dec 28, 2022
COM2022INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (4) 70 CFM EXHAUST SYSTEMS , (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) # DRAIN TILE, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (12) # PLUMBING FIXTURES AS PER CODE.$4,000Oct 31, 2022
COM2022ALL WINDOWS, TRANSOM AND DOOR REPLACEMENT ASSEMBLIES MUST FIT WITHIN EXISTING STRUCTURAL OPENINGS AND COMPLEMENT CHARACTER OF EXISTING STRUCTURE. SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATION. TO INCLUDE: INTERIOR DEMOLITION (CAT 1): REMOVE AND REPLACE EXISTING DRYWALL, INSTALL NEW LAMINATE FLOORING, REPLACE 10 WINDOWS SAME SIZE AND LOCATION. REPLACE 3 EXTERIOR DOORS SAME SIZE AND LOCATION, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE.******** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS MUST COMPLY WITH BROADWAY EAST URBAN RENEWAL PLAN PAGE 21 '' REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE.''$40,000Sep 21, 2022

Violations

5
KindCategoryStatusFineBalanceDate
service_requestSW-Dirty AlleyClosedJun 22, 2026
citationPM 305.1P$50$0May 12, 2026
service_requestHCD-Sanitation PropertyClosedMay 6, 2026
citationHE 7-608.1P$1,000$0Apr 25, 2025
citation13 4-5A.2P$500$0Apr 25, 2025

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.