Baltimore City · 21202

1322 AISQUITH ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$322,867
Land use
Residential (R)
Year built
1900
Last sale
Jun 11, 2024

Assessment

OwnerKABARA, CHRISTOPHER
Land useResidential (R)
Total assessment$322,867 (cycle 2026)
Last saleJun 11, 2024 — $349,798
Year built1900
ZoningR-8
Vacant

Permits

9
TypeDescriptionCostIssued
USE2024USE AS A SINGLE-FAMILY DWELLING.Jan 31, 2024
COM2024REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-60817:EXTERIOR: WASH CLEAN AND POINT FRONT BRICK PER AND STUCCO REAR PER CHAP. NEW ROOF WITH ALL NEW JOIST FRAMING AND SHEATHING. INSTALL NEW WINDOWS (13) NEW DOORS (2). REPLACE EXISTING PATIO SAME SIZE SAME LOCATION (140 SQ FT). REPLACE EXISTING 6 FEET FENCE SAME SIZE SAME LOCATION (70 FEET). INTERIOR: ALL NEW RENOVATION OF BASEMENT, FIRST, SECOND AND THIRD FLOOR PER PLANS. MEPS TO BE APLLIED FOR BY OTHERS. NEW STAIR FROM BASEMENT TO THIRD LEVEL PER THE PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH IRC 2018 AND BALTIMORE CITY BUILDING CODE REQUIREMENTS.********** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS MUST COMPLY WITH OLIVER URBAN RENEWAL PLAN PAGE 38 ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. '' REPLACEMENT FENCE SHALL COMPLY WITH REGULATIONS ON PAGE 39 OF THE OLIVER URBAN RENEWAL PLAN '' SCREENING (PRIVACY FENCING) IS PERMITTED AROUND BACK YARDS. IT MAY BE OPAQUE TO A MAXIMUM OF 48 INCHES. THERE MAY BE UP TO AN ADDITIONAL 24 INCHES OF FENCE IN A LATTICE OR PICKET STYLE.'') Original Permit Description:(COM2023-60817) EXTERIOR: WASH CLEAN AND POINT FRONT BRICK PER AND STUCCO REAR PER CHAP. NEW ROOF WITH ALL NEW JOIST FRAMING AND SHEATHING. INSTALL NEW WINDOWS (13) NEW DOORS (2). REPLACE EXISTING PATIO SAME SIZE SAME LOCATION (140 SQ FT). REPLACE EXISTING 6 FEET FENCE SAME SIZE SAME LOCATION (70 FEET). INTERIOR: ALL NEW RENOVATION OF BASEMENT, FIRST, SECOND AND THIRD FLOOR PER PLANS. MEPS TO BE APLLIED FOR BY OTHERS. NEW STAIR FROM BASEMENT TO THIRD LEVEL PER THE PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH IRC 2018 AND BALTIMORE CITY BUILDING CODE REQUIREMENTS.********** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS MUST COMPLY WITH OLIVER URBAN RENEWAL PLAN PAGE 38 ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. '' REPLACEMENT FENCE SHALL COMPLY WITH REGULATIONS ON PAGE 39 OF THE OLIVER URBAN RENEWAL PLAN '' SCREENING (PRIVACY FENCING) IS PERMITTED AROUND BACK YARDS. IT MAY BE OPAQUE TO A MAXIMUM OF 48 INCHES. THERE MAY BE UP TO AN ADDITIONAL 24 INCHES OF FENCE IN A LATTICE OR PICKET STYLE.''Jan 8, 2024
COM2023 Extend Original Permit.(original permit:COM2023-67752:INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2023-67752) INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP AS PER CODE.Dec 29, 2023
COM2023INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (12) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$16,000Aug 9, 2023
COM2023INSTALL (14) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE.$500Jul 26, 2023
COM2023INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 30000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP AS PER CODE.$18,000May 31, 2023
COM2023EXTERIOR: WASH CLEAN AND POINT FRONT BRICK PER AND STUCCO REAR PER CHAP. NEW ROOF WITH ALL NEW JOIST FRAMING AND SHEATHING. INSTALL NEW WINDOWS (13) NEW DOORS (2). REPLACE EXISTING PATIO SAME SIZE SAME LOCATION (140 SQ FT). REPLACE EXISTING 6 FEET FENCE SAME SIZE SAME LOCATION (70 FEET). INTERIOR: ALL NEW RENOVATION OF BASEMENT, FIRST, SECOND AND THIRD FLOOR PER PLANS. MEPS TO BE APLLIED FOR BY OTHERS. NEW STAIR FROM BASEMENT TO THIRD LEVEL PER THE PLANS. ALL WORK SHALL BE IN ACCORDANCE WITH IRC 2018 AND BALTIMORE CITY BUILDING CODE REQUIREMENTS.********** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS MUST COMPLY WITH OLIVER URBAN RENEWAL PLAN PAGE 38 ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. '' REPLACEMENT FENCE SHALL COMPLY WITH REGULATIONS ON PAGE 39 OF THE OLIVER URBAN RENEWAL PLAN '' SCREENING (PRIVACY FENCING) IS PERMITTED AROUND BACK YARDS. IT MAY BE OPAQUE TO A MAXIMUM OF 48 INCHES. THERE MAY BE UP TO AN ADDITIONAL 24 INCHES OF FENCE IN A LATTICE OR PICKET STYLE.''$280,000Apr 25, 2023
COM2022SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY II): REMOVAL OF THE PLASTER, TRIM, NON-STRUCTURAL WALLS, DOORS, WINDOWS AND REMOVAL OF ALL ASSOCIATED DEBRIS, FRAMING ON THE PERIMETER WALLS AND TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW TRIM, INSTALL NEW INTERIOR DOORS, INSTALL NEW FINISHES, RECONSTRUCTION OF PORTION OF THE FLOOR JOISTS SYSTEM, RECONSTRUCTION OF THE REAR PORTION OF THE 2ND FLOOR, REPLACEMENT OF WINDOWS AND EXTERIOR DOORS (WINDOWS AND DOORS WILL BE REPLACED IN THE SAME SIZE AND LOCATION, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK.(*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES).$65,000May 9, 2022
COM2022INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY I): REMOVAL OF THE CURRENT DEBRIS (WOOD AND PLASTER) AND TRASH. REMOVAL OF NON-STRUCTURAL WALLS, FLOORING AND REMOVAL OF ALL ASSOCIATED DEBRIS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, AND SEPARATE PERMITS WILL BE PULLED FOR ANY INTERIOR RENOVATIONS.$1,000Mar 23, 2022

Violations

0

No violations on record.

Inspections

1
TypeStatusActionDate
InitialECBNot FinishedISSUE CITATION NOTICEMar 11, 2022