Baltimore City · 21213

1806 N CAROLINE ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$22,333
Land use
Residential (R)
Year built
1920
Last sale
Feb 4, 2026

This owner holds 2 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerBEBETTER17 LLC
Land useResidential (R)
Total assessment$22,333 (cycle 2026)
Last saleFeb 4, 2026 — $150,000
Year built1920
ZoningR-8
VacantYes

Permits

6
TypeDescriptionCostIssued
COM2024INSTALL (1) 150 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (27) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$4,500Apr 5, 2024
COM2024REPLACE FLOOR JOISTS 2X10 16” OC FOR ALL LEVELS. REPLACE ROOF RAFTERS 2X12 24” OC. INSTALL NEW PLYWOOD SUBFLOOR 3/4IN T&G. INSTALL NEW FRAMING ALL THROUGHOUT WITH 2X4 16”OC. REPLACE FRONT, REAR, AND BASEMENT DOOR SAME SIZE AND LOCATION. REPLACE 13 WINDOWS SAME SIZE AND LOCATION. INSULATE WALLS WITH R-21 AND CEILING WITH R-49. INSTALL NEW DRYWALL THROUGHOUT. MUD, SAND AND PAINT. INSTALL NEW VINYL FLOORING AND CABINETRY. INSTALL CERAMIC TILE TO BATHROOM FLOORS AND SHOWER WALLS. AS PER CODE************* AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH THE REGULATIONS ON PAGE 40 OF THE OLIVER URBAN RENEWAL PLAN. THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY. ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. ''$10,000Mar 27, 2024
COM2024INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 70000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 12000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$10,000Mar 21, 2024
COM2024INSTALL (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # ELECTRIC WATER HEATER, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 90000 BTU FUEL-BURNING EQUIP AS PER CODE.$1,000Mar 17, 2024
COM2023SCOPE OF WORK: ------ INTERIOR ALTERATIONS ------TO INCLUDE CAT 2 DEMO ALL INTERIOR WALLS AND CEILING. REMOVE MAIN STAIRCASE AND FLOOR JOIST ON 1ST AND 2ND FLOORS. HAUL AWAY ALL CONSTRUCTION DEBRIS. AS PER CODE$10,000Dec 28, 2023
COM2023SCOPE OF WORK: ----- INTERIOR ALTERATIIONS---- NEW FLOORING, NEW INTERIOR WALLS, NEW INTERIOR DOORS, NEW KITCHEN, NEW BATHROOMS. *STRUCTURAL WORK-NEW FLOOR JOISTS AT ALL LEVELS. --- EXTERIOR ALTERATIONS ---- NEW ROOF FRAMING, NEW ROOF INSULATION, REPLACE EXISTING WINDOWS SAME SIZE & LOCATION, NEW RUBBERIZED DECK AT LEVEL 2 ROOF. AS PER PLANS AND AS PER CODE.*************** AS PER THE DEPARTMENT OF PLANNING:REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH THE REGULATIONS ON PAGE 40 OF THE OLIVER URBAN RENEWAL PLAN. THE WINDOW AND DOOR OPENINGS SHALL NOT BE ALTERED OR REDUCED IN SIZE IN ANY WAY. ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED. $50,000Oct 26, 2023

Violations

2
KindCategoryStatusFineBalanceDate
vacant_building_noticeVacantopenMar 12, 2026
citationBC 123.8.1P$1,000$0Dec 8, 2025

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.