Baltimore City · 21213
1315 E LAFAYETTE AVE
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $260,000
- Land use
- Residential (R)
- Year built
- 1920
- Last sale
- Nov 8, 2024
Assessment
| Owner | BROWNE, RICHARD |
|---|---|
| Land use | Residential (R) |
| Total assessment | $260,000 (cycle 2026) |
| Last sale | Nov 8, 2024 — $270,000 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | — |
Permits
8| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2024 | USE AS A SINGLE-FAMILY DWELLING. | — | Feb 26, 2024 |
| COM2023 | I WANT TO ADD ON TO PERMIT NUMBER COM2023-64461 AS WE WANT TO ADD A REAR CONCRETE DECK ON THE FIRST FLOOR, IT WILL BE A 5'' CONCRETE SLAB WITH WIRE MESH ON TOP OF COMPACTED SOIL IT WILL BE REINFORCED WITH A 8''X16'' CONCRETE FOOTING WITH 8'' CMU FOOTING WALL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS | $5,000 | Jan 9, 2024 |
| COM2023 | AA CONV: Full Description Loaded as Comment | — | Dec 28, 2023 |
| COM2023 | INSTALL (5) # PLUMBING FIXTURES AS PER CODE. | $1,500 | Oct 1, 2023 |
| COM2023 | INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE. | $18,000 | Sep 20, 2023 |
| COM2023 | INSTALL (17) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | $2,000 | Sep 5, 2023 |
| COM2023 | INSTALL (16) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE ( 1-2 FAM. RES.), (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 30000 BTU FUEL-BURNING EQUIP AS PER CODE. | $13,000 | Aug 18, 2023 |
| COM2023 | (CATEGORY II) DEMOLITION: REMOVAL OF THE PLASTER, NON-STRUCTURAL WALLS, FLOORING, DOORS AND REMOVAL OF ALL ASSOCIATED DEBRIS, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW INTERIOR DOORS, INSTALL NEW INSULATION (R20WALLS/R49CEILINGS), INSTALLATION OF NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), STRUCTURAL INFILL AT STAIRCASE, REPLACEMENT OF 10 WINDOWS AND 3 EXTERIOR DOORS (IN THE SAME SIZE AND LOCATION), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM WIDTH OF 70SQ.FT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)*********************** AS PER THE DEPARTMENT OF PLANNING: REPLACEMENT WINDOWS AND DOORS SHALL COMPLY WITH OLIVER URBAN RENEWAL PLAN PAGE 40 ''ALL WINDOWS MUST BE TIGHT FITTING AND HAVE SASHES OF PROPER SIZE AND DESIGN FOR THEIR HISTORIC CONTEXT. SASHES WITH ROTTEN WOOD, BROKEN JOINTS, OR BROKEN OR LOOSE MULLIONS OR MUNTINS SHALL BE REPLACED. • REPLACEMENT WINDOWS MUST USE THE ENTIRE EXISTING OPENING. WOOD IS PREFERRED AS REPLACEMENT MATERIAL, VINYL IS ACCEPTABLE. • SELECTING CORRECT REPLACEMENT WINDOWS IS KEY TO MAINTAINING THE ARCHITECTURAL INTEGRITY OF THE NEIGHBORHOOD. REPLACEMENT WINDOWS SHOULD MATCH THE HISTORIC WINDOWS THEY ARE REPLACING, IN PATTERN, MULLION AND FRAME SIZE. • EXISTING MASONRY OPENINGS MAY NOT BE ENLARGED EXCEPT TO ACCOMMODATE CONTEMPORARY DOOR DIMENSIONS. IF NECESSARY TO ENLARGE AN OPENING, THE ENTIRE MASONRY OPENING, DOOR AND TRANSOMS MUST BE ENLARGED. THE OPENING MUST BE CUT CLEANLY AND FINISHED AS APPROPRIATE. • WINDOW AND DOOR OPENINGS IN THE FRONT OF THE BUILDING SHALL NOT BE FILLED OR BOARDED. • ENCLOSURES OR SECURITY GRILLES AND SCREENS SHOULD BE AS INCONSPICUOUS AS POSSIBLE AND COMPATIBLE WITH OTHER ELEMENTS OF THE FAÇADE. SOLID OR PERFORATED METAL SECURITY DEVICES ARE NOT PERMITTED. • DORMER WINDOWS ON ROOFS SLOPING TOWARD THE STREET SHALL BE RETAINED AND REPAIRED OR REPLACED IN AN APPROPRIATE MANNER TO PRESERVE THEIR ORIGINAL ARCHITECTURAL DESIGN. • SPECIAL WINDOWS, SUCH AS BAYS, BOXES AND DORMERS, SHOULD BE REFURBISHED WHEN POSSIBLE, AND WHEN NECESSARY REPLACED WITH QUALITY FACSIMILES. • HISTORIC WOOD FRONT DOORS MAY BE REPLACED WITH STEEL DOORS, BUT MUST HARMONIZE WITH THE HISTORIC CONTEXT. BOTH WOOD AND METAL DOORS SHOULD HAVE A PANELIZED APPEARANCE. GLAZING IS ENCOURAGED | $70,000 | Jun 30, 2023 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: SW-HGWJul 8, 2026 · 47 m · 1300 E LAFAYETTE AVE
- violation: HCD-Illegal DumpingJul 8, 2026 · 82 m · 1804 AIKEN ST
- violation: SW-HGWJul 7, 2026 · 90 m · 1230 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 94 m · 1228 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 97 m · 1226 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 101 m · 1224 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 105 m · 1222 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 109 m · 1220 E LAFAYETTE AVE
- violation: SW-HGWJul 7, 2026 · 115 m
- violation: SW-Dirty AlleyJul 3, 2026 · 50 m
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;