Permits

4
TypeDescriptionCostIssued
COM2023GUTTER REPL AND CHIMNEY/ROOF REPAIR -SCOPE OF WORK TO FOLLOW CHAP ATP EXACTLY. ALL WORK PER CODE.************* AS PER THE CHAP ATP: GUTTER REMOVE AND REPLACE THE FRONT LEFT AND FRONT RIGHT SIDE, BUILT-IN GUTTER SYSTEMS ON THE FRONT OF THE HOUSE. NEW COPPER GUTTERS WILL BE FABRICATED FROM 20 OZ COPPER TO MATCH OR IMPROVE THE EXISTING DESIGN AND SOLDERED AT THE SEAMS. AN OUTLET DOWNSPOUT ELBOW WILL BE SOLDERED TO THE NEW GUTTER TO LEAD WATER TO A NEW COPPER COLLECTOR HEAD AND MOUNTED IN THE SAME PLACE AS THE OLD COLLECTOR HEAD IN ORDER TO REUSE THE MAIN DOWNSPOUTS COPING CAPS INSTALL APPROXIMATELY 30 FEET OF COPING CAP OVER THE BROWNSTONE CAPS ON THE REVERSE GABLE OF THE FRONT SLATE ROOF AND THE PARTY WALL BETWEEN THE HOUSES. CAPS ARE TO BE FABRICATED FROM 20 OZ COPPER. COPPER CAPS WILL BE CLEATED AND POP RIVETED IN PLACE. STEP AND COUNTER FLASHING REPLACEMENT: REMOVE AND REPLACE STEP AND COUNTER FLASHING AT THE LEFT AND RIGHT SIDES OF THE MAIN WINDOW DORMER. SLATE WILL BE REMOVED AROUND THE FLASHING TO PROPERLY REMOVE DEGRADED FLASHING. WOOD DECKING WILL BE REPAIRED AS NECESSARY. HIGH-GRADE UNDERLAYMENT WILL BE INSTALLED USING CAP NAILS. KICK-OUT AND TRANSITION FLASHING WILL BE SOLDERED AT CRITICAL, LEAK-PRONE AREAS, FOR A WATER-TIGHT SEAL. NEW FLASHING WILL BE MADE FROM 16 OZ COPPER. THE ORIGINAL SLATE WILL BE REINSTALLED AFTER NEW FLASHING HAS BEEN INSTALLED. THE DAMAGED SLATE WILL BE REPLACED WITH THE SAME RECLAIMED PEACH BOTTOM SLATE. SLATE REPAIR: REMOVE AND REPLACE (15) DAMAGED OR BROKEN-FIELD SLATE ON THE FRONT SLATE ROOF REPLACEMENT SLATE WILL BE THE SAME SIZE (16”X9”) AND OF THE SAME QUARRIED (PEACH BOTTOM) SLATE. ALUMINUM BIBS WILL BE BLACK. ADD ON: (34) NON-PEACH BOTTOM SLATE CAN BE REPLACED IN ORDER TO RESTORE THE SLATE ROOF TO ITS ORIGINAL CONDITION. CHIMNEY FLASHING & TUCK POINT: REMOVE AND REPLACE CHIMNEY FLASHING NEW FLASHING WILL BE FABRICATED ON-SITEFROM 16 OZ COPPER USING MASTER ROOFING TECHNIQUES FOR LONG LASTING PROTECTION AROUND THE CHIMNEY. CORNERS ARE TO BE SOLDERED USING 50/50 LEAD/TIN SOLDER AND COUNTER FLASHINGS TO BE INSTALLED USING THE TUCK FLASHING METHOD. REGLET IS TO BE SEALED USING LIMESTONE-COLORED POLYURETHANE SEALANT. LEFT CHIMNEY IS TO HAVE TUCKPOINTING WITH NEW HIGH-STRENGTH CONCRETE MORTAR AS NECESSARY TO REPAIR DEGRADED MORTAR JOINTS. THE OLD JOINT WILL BE GROUND OUT AND CLEANED TO REMOVE DUST AND DEBRIS BEFORE NEW JOINTS ARE APPLIED. ALL WORK TO MATCH PLANS/INFORMATION/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES IT.$33,525Aug 10, 2023
COM2023INSTALL (2) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (11) # FIXTURES/DEVICES, (5) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$2,500Aug 3, 2023
COM2023#1 ADD 4 FEET OF CONCRETE TO EXISTING DRIVEWAY TO ENLARGE SIZE #2 PUT A SLAB OF CONCRETE TO MAKE A BLUESTONE PATIO (PATIO DIMENSIONS 4 INCHES THICK X 17 FEET LEND X 12 FEET WIDE; BLUESTONE WILL BE SEAT AT THE CONCRETE SLAB #3 BUILD A WOOD FENCE BETWEEN DRIVEWAY AND BLUESTONE PATIO (WOOD FENCE DIMENSIONS 17 FEET LONG X 6 FEET HIGH, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED SKETCH******** AS PER CHAP:ADD 4 FEET OF CONCRETE TO THE EXISTING DRIVEWAY TO ENLARGE THE SIZE (4INCH X 4 FEET X17 FEET) MAKE A CONCRETE PATIO TO PUT BLUESTONES ON TOP OR A CONCRETE PATIO (CONCRETE AND BLUESTONE DIMENSIONS 12 FEET X 17 FEET BUILDA WOOD FENCE BETWEEN THE DRIVEWAY AND BLUESTONES PATIO) WOOD FENCE DIMENSIONS 6 FEET HIGH X 17 FEET LEND PRODUCTS: PENNSYLVANIA BLUESTONE 12X12, 6’H X 8’W PRESSURE TREATED PINE DOG EAT FENCE PANEL ALL WORK TO MATCH PLANS/INFORMATION/SPECS IN CHAP FILES EXCEPT WHERE THIS ATP SUPERSEDES IT. $15,000Apr 17, 2023
COM2022INSTALL (1) # SANITARY CONNECTION (1-2 FAM. RES.) AS PER CODE.$8,760Jun 16, 2022

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.