Permits
21| Type | Description | Cost | Issued |
|---|---|---|---|
| BCCM | BFPE International has been contracted to provide a new clean agent fire suppression system for the BMA Phase 5 project located in Baltimore, MD. The system will protect the Paintings Vault, Objects Vault, AAAPI Vault and the Workroom. The systems will be a main only. Clean Agent Fire Suppression System BFPE International is providing and installing all equipment for the fire suppression system. This includes the clean agent cylinder, nozzles, ancillary devices, and associated piping. BFPE International will perform a door fan test to evaluate the integrity of the enclosure. Actual sealing of the enclosure is to be provided by another contractor. Fire Detection/Releasing System BFPE International is providing and installing all equipment for the fire releasing system. This includes a releasing control panel, with back-up batteries, associated modules and relays, and associated wiring. The 120VAC power for the releasing control panel is to be provided by another contractor. BFPE International is providing connections only to tie into the base building fire alarm system. Contacts will be provided for discharge per zone, supervisory, and trouble. The wiring and programming of the base building fire alarm system, including modification of the base building annunciator if applicable, is to be provided by another contractor. All indicating and initiating devices are being provided and installed by others. | $304,000 | Jan 13, 2026 |
| BCCM | Fire Alarm and Vesda system installation - Furnish Fire Alarm System equipment & devices - Furnish VESDA System adequate for coverage area - Furnish Suppression Release Control and associated equipment - Fire Alarm shop drawings and device documentation. - Programming, Check-out and start-up - AHJ Testing oversight - Project Programming retrieval and demo device removal - All Suppression Control panels and equipment required to be part of the Fire Alarm Control System - Spare Equipment and Demonstration - Existing system will remain and new/additional equipment will be added to the existing program for areas included on the provided plans AS PER PLANS AS PER CODE. | $100,000 | Nov 10, 2025 |
| BCCM | ********* Amend Permit COM2024-03631 issued on 4/2/2025 to revise design of 1392 sq ft Textile Center space shown as******** SCOPE OF WORK: --------- INTERIOR ALTERATIONS --------- - Add-alternate 1 into an open Caplan Gallery that connects to the adjacent 1886 sq ft NW Cone gallery as per plans and as per code. ********** Revisions from the original permit documents are clouded and referred to as Add-alternate 2. Add-alternate 1 was not accepted by the client. ********** | $616,206 | Oct 2, 2025 |
| BCCM | BFPE to modify the existing pre-action system feeding the NW cone to provide new coverage for the remodel. Additionally, on the same system, all piping feeding into the Caplan Gallery is to be replaced and modified to feed the remodel of that room as well. | $39,800 | Oct 1, 2025 |
| COM2024 | SCOPE OF WORK: ------ LEVEL II INTERIOR ALTERATIONS ------ THIS +/- 8,000 SF RENOVATION WILL CREATE UPGRADED GALLERY SPACE WITHIN THE NW CONE WING (1985), PROVIDE ADDITIONAL ART STORAGE CAPACITY FOR PAINTINGS AND LARGE AND SMALL OBJECTS ON THE GROUND FLOOR OF THE JACOBS WING (1936). IN ADDITION, THERE IS AN ALTERNATE TO CREATE A NEW TEXTILE STUDY CENTER THAT WILL SERVE AS AN EDUCATION VENUE FOR STUDENTS AND SCHOLARS, AND MINOR EXTERIOR MASONRY CLEANING AND REPAIR SCOPE IN THE ANTIOCH COURT. AS PER PLANS AS PER CODE. | — | Apr 2, 2025 |
| COM2023 | RELOCATED 4 PENDENTS TO ACCOMMODATE THE NEW TENANT LAYOUT AS PER PLANS AS PER CODE. | $5,780 | May 15, 2023 |
| COM2022 | INTERIOR RENOVATIONS TO EXISTING CLASSROOM WHICH INCLUDE NEW CABINETRY, MILLWORK, TRIM AND FINISHES, ALSO INCLUDES NEW GALLERY EXHIBIT WALL COMPOSED OF CABINETRY, MILLWORK, TRIM AND LIGHTING. PLUS MINOR GALLERY SPACE IMPROVEMENTS AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEMS. | $150,000 | Feb 8, 2023 |
| COM2022 | INSTALL (9) # ANNUAL TESTING INSPECTION AS PER CODE. TEST AND CERTIFY 9 BACKFLOW PREVENTORS. | $5,000 | Dec 27, 2022 |
| COM2022 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INSTALL 190 LOW VOLTAGE OUTLETS FR DATA / A/V / SECURITY, PERMIT FROM SPRING 2021 EXPIRED AND NEEST TO BE RENEWED FRO INSPECTION PURPOSES. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AS PER CODE. | $25,000 | Apr 20, 2022 |
| COM2022 | AMEND COM2021-00662 ISSUED 5/12/2021 FOR THIRD FLOOR PLANS AFTER COORDINATION, ALL CALCS REVISED TO NEW PUMP TEST, LARGEST PIPE SIZE: 4. TOTAL # OF HEADS 170 AS PER PLANS AS PER CODE. (FPP#204742) | $80,000 | Apr 12, 2022 |
| COM2021 | INSTALL 3 FIRE SUPPRESSION CLEAN AGENT SYSTEMS AS PER PLANS AS PER CODE. | $30,000 | Sep 30, 2021 |
| COM2021 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2020-01942:INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM.) Original Permit Description:(COM2020-01942) INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM. | — | Aug 12, 2021 |
| COM2021 | VSC TO MODIFY EXISTING SPRINKLER SYSTEM AND ADD 2 NEW PREACTION SPRINKLER SYSTEMS, 172 NEW SPRINKLERS AS PER PLANS AS PER CODE. | $196,460 | May 12, 2021 |
| COM2021 | SCOPE OF WORK: ELECTRICAL ALTERATIONS TO INCLUDE: INSTALL 190 LOW VOLTAGE CABLES AND COMMUNICATIONS OUTLETS FOR DATA, VOICE, A/V, AND SECURITY DEVICES. AS PER CODE. | $50,000 | Apr 2, 2021 |
| COM2021 | INSTALL (20) # LOW VOLTAGE AS PER CODE. | $20,000 | Mar 31, 2021 |
| COM2020 | AMEND PERMIT: ADD HVAC CONTRACTOR . (ORIGINAL PERMIT:COM2020-01942:INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM.) Original Permit Description:(COM2020-01942) INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM. | — | Dec 9, 2020 |
| COM2020 | AMEND PERMIT: ADD PLUMBER CONTRACTOR .(ORIGINAL PERMIT:COM2020-01942:INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM.) Original Permit Description:(COM2020-01942) INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM. | — | Dec 9, 2020 |
| COM2020 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2020-01942:INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM.) Original Permit Description:(COM2020-01942) INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM. | — | Dec 2, 2020 |
| COM2020 | INTERIOR RENOVATIONS RECONFIGURING EXISTING GALLERY, ART STORAGE AND STAFF OFFICE SPACES AT THE 1ST FLOOR AND 3RD FLOORS, EXISTING BATHROOMS TO BE UPDATED TO MEET ADA COMPLIANCE, EXISTING ART STORAGE VAULTS TO BE RECONFIGURED AND PROVIDED WITH UPDATED FIRE SUPPRESSION SYSTEMS, WORK WILL BE PHASED: FIRST FLOOR RENOVATION TO OCCUR FIRST, ALLOWING 3RD OCCUPANTS TO MOVE-IN, THEN THIRD FLOOR WORK WILL START AFTER MOVE-IN AS PER PLANS AS PER CODE. SEPARATE PERMIT REQUIRED FOR SPRINKLER AND FIRE ALARM SYSTEM. | $11,300,000 | Oct 9, 2020 |
| COM2020 | AMEND TO ADD ELECTRICAL CONTRACTOR: (ORIGINAL PERMIT:COM2020-00131:INSTALL TWO LIGHT POLES ON EXISTING CIRCUIT AS PER PLANS AS PER CODE. NO PAVING OR ROADWAY DISTURBED.) Original Permit Description:(COM2020-00131) INSTALL TWO LIGHT POLES ON EXISTING CIRCUIT AS PER PLANS AS PER CODE. NO PAVING OR ROADWAY DISTURBED. | — | May 12, 2020 |
| COM2020 | INSTALL TWO LIGHT POLES ON EXISTING CIRCUIT AS PER PLANS AS PER CODE. NO PAVING OR ROADWAY DISTURBED. | $5,000 | May 8, 2020 |