Assessment
| Owner | GRIFFITH, LEZA MARIA |
|---|---|
| Land use | Residential (R) |
| Total assessment | $448,733 (cycle 2026) |
| Last sale | Jan 23, 2024 — $505,000 |
| Year built | 1880 |
| Zoning | R-6 |
| Vacant | — |
Permits
12| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2024 | INTERIOR WORK: REPLACE INSULATION AND DRYWALL IN BEDROOM AND LIVING ROOM, 350 SF. REPAIR TRIM AND REPLACE/REFINISH WOOD FLOORING. EXTERIOR WORK: REPLACE 32' OF DAMAGED FENCING WITH 6' HIGH X 8' WOOD PRESSURE TREATED PANELS IN BETWEEN 4X4 SUPPORTS PER PLAN AND PER CODE. ADD NEW 12' WIDE SLIDING GATE PER PLAN AND PER CODE. GATE HEIGHT WILL NOT EXCEED 6' AND ALL WORK TO BE INSIDE OF PROPERTY LINES. ROOF REPAIR W/NEW TORCH DOWN MEMBRANE NO PLYWOOD WORK REQUIRED. EXCAVATE 50 LF PER PLANS ATTACHED AND PER CODE TO PARGE AND WATERPROOF EXISTING BLOCK FOUNDATION. EXCAVATION WILL BE ABOVE FOOTING. ALL WORK WITHIN PROPERTY LINES. | $7,500 | Oct 17, 2024 |
| USE2023 | USE AS A SINGLE-FAMILY DWELLING. | — | Apr 27, 2023 |
| COM2023 | REINSTATE PERMIT: CHANGE ELECTRICAL CONTRACTOR . EXTEND ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-67293:INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.) Original Permit Description:(COM2022-67293) INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | — | Apr 25, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-56921:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR & SIDE WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (20). NEW EXTERIOR WORK: NEW 2-STORY REAR AND SIDE ADDITION (16'-1.5''X11'-2'') + (2'-11''X12'-1'') = (215.5 SF) PER BMZA2021-331. NEW EXTERIOR DOORS (3), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) ) Original Permit Description:(COM2022-56921) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR & SIDE WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (20). NEW EXTERIOR WORK: NEW 2-STORY REAR AND SIDE ADDITION (16'-1.5''X11'-2'') + (2'-11''X12'-1'') = (215.5 SF) PER BMZA2021-331. NEW EXTERIOR DOORS (3), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | — | Apr 17, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-67592:INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 90000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 60 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ) AS PER CODE.) Original Permit Description:(COM2022-67592) INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 90000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 60 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ) AS PER CODE. | — | Apr 5, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-67814:INSTALL (15) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2022-67814) INSTALL (15) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Mar 30, 2023 |
| COM2022 | INSTALL (15) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (1) 90000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP AS PER CODE. | $1,100 | May 19, 2022 |
| COM2022 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 90000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 60 CFM NEW DISTRIBUTION SYSTEM (OTHER THAN 1-2 FAMILY ) AS PER CODE. | $85,000 | May 17, 2022 |
| COM2022 | INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | $100 | May 16, 2022 |
| COM2022 | INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR & SIDE WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (20). NEW EXTERIOR WORK: NEW 2-STORY REAR AND SIDE ADDITION (16'-1.5''X11'-2'') + (2'-11''X12'-1'') = (215.5 SF) PER BMZA2021-331. NEW EXTERIOR DOORS (3), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | $80,000 | Mar 11, 2022 |
| BMZ2021 | construct a two-story rear and side addition. | — | Dec 17, 2021 |
| COM2021 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS | $5,000 | Dec 16, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BCCMJul 10, 2026 · 114 m · 3900 ROLAND AVE
- permit: BRCMJul 8, 2026 · 111 m · 3819 FALLS RD
- permit: BCCMJul 6, 2026 · 101 m · 3818 ROLAND AVE
- violation: PM 305.3Jul 2, 2026 · 117 m · 1101 W 38TH ST
- permit: BRCMJun 30, 2026 · 113 m · 1016 UNION AVE
- violation: HCD-Sanitation PropertyJun 28, 2026 · 116 m · 1101 W 38TH ST
- violation: SW-HGWJun 25, 2026 · 47 m · 3804 HICKORY AVE
- violation: HCD-Sanitation PropertyJun 18, 2026 · 47 m · 3804 HICKORY AVE
- violation: HCD-Sanitation PropertyJun 8, 2026 · 82 m · 3754 HICKORY AVE
- violation: HCD-Zoning InvestigationJun 8, 2026 · 82 m · 3754 HICKORY AVE