| Owner | 2313 BRYANT LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $212,767 (cycle 2026) |
| Last sale | Oct 15, 2024 |
| Year built | 1920 |
| Zoning | R-7 |
| Vacant | — |
Permits
7| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2022 | USE AS A SINGLE-FAMILY DWELLING. | — | Nov 7, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2022-61073:SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4'' CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4'' 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16'' ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16'' O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12'' O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4'' TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF FRONT PORCH ROOF AND BACK STAIRS (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)) Original Permit Description:(COM2022-61073) SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4'' CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4'' 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16'' ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16'' O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12'' O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4'' TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF FRONT PORCH ROOF AND BACK STAIRS (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) | — | Oct 25, 2022 |
| COM2022 | INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 60 CFM EXHAUST SYSTEMS AS PER CODE. | $85,000 | Aug 10, 2022 |
| COM2022 | INSTALL (18) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE. | $3,200 | Jul 18, 2022 |
| COM2022 | INSTALL (1) # ELECTRIC WATER HEATER, (1) # SANITARY CONNECTION, NEW INTERIOR, (1) # WATER SERVICE PIPE, NEW INTERIOR, (12) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE ( 1-2 FAM. RES.), (1) 100 BTU FUEL-BURNING EQUIP AS PER CODE. | $7,500 | May 11, 2022 |
| COM2022 | SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4'' CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4'' 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16'' ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16'' O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12'' O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4'' TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF FRONT PORCH ROOF AND BACK STAIRS (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) | $120,000 | Mar 30, 2022 |
| COM2022 | . ? CATEGORY II THIS INCLUDES ALL OR PART OF CATEGORY I NON-STRUCTURAL DEMOLITION (INCLUDES THE REMOVAL OF PLASTER, DRYWALL, INTERIOR DOORS, NON-BEARING WALLS, ROOFING MATERIAL, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT)AND ALLOWS THE REMOVAL OF UP TO 1/3 OF LIKE STRUCTURAL MEMBERS ON THAT LEVEL. THE REMAINING STRUCTURE MUST BE SECURED. * EXAMPLE: THE REMOVAL OF 6 OF THE TOTAL 18 FLOOR JOISTS ON THE 2ND FL. OR THE REMOVAL OF 5 OF THE TOTAL 15 ROOF RAFTERS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, SEPARATE PERMIT WILL BE PULLED FOR ANY INTERIOR RENOVATIONS/TENANT FITOUT | $14,000 | Mar 18, 2022 |
Violations
1| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| citation | PM 305.2.2 | P | $50 | $0 | Jun 5, 2025 |
Inspections
5| Type | Status |
|---|---|
| Initial | OPEN |
| Initial | OPEN |
| Initial | OPEN |
| InitialECB | OPEN |
| Initial | OPEN |
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 9, 2026 · 117 m · 2203 BRYANT AVE
- permit: BRCMJul 9, 2026 · 149 m · 2909 PARKWOOD AVE
- violation: SW-HGWJul 8, 2026 · 139 m · 2235 OREM AVE
- violation: SW-HGWJul 8, 2026 · 141 m · 2233 OREM AVE
- violation: SW-Dirty AlleyJul 7, 2026 · 140 m · 2203 WHITTIER AVE
- violation: SW-Dirty AlleyJul 6, 2026 · 130 m · 2200 WHITTIER AVE
- permit: BRCMJul 2, 2026 · 149 m · 2909 PARKWOOD AVE
- violation: SW-HGWJul 1, 2026 · 27 m · 2305 BRYANT AVE
- violation: SW-Dirty AlleyJul 1, 2026 · 150 m · 2415 REISTERSTOWN RD
- violation: SW-HGWJun 30, 2026 · 9 m · 2315 BRYANT AVE