Permits

6
TypeDescriptionCostIssued
USE2022USE AS A SINGLE FAMILY DWELLINGOct 13, 2022
COM2022AA CONV: Full Description Loaded as CommentSep 2, 2022
COM2022 Extend Original Permit.(original permit:COM2022-57122:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 72000 BTU FUEL-BURNING EQUIP(FURNACE), (14) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (1) 50000 BTU FUEL-BURNING EQUIP, (2) 72000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2022-57122) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 72000 BTU FUEL-BURNING EQUIP(FURNACE), (14) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (1) 50000 BTU FUEL-BURNING EQUIP, (2) 72000 BTU FUEL-BURNING EQUIP AS PER CODE.Sep 2, 2022
COM2022INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 72000 BTU FUEL-BURNING EQUIP(FURNACE), (14) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (1) 50000 BTU FUEL-BURNING EQUIP, (2) 72000 BTU FUEL-BURNING EQUIP AS PER CODE.$7,000Mar 9, 2022
COM2021PER CHAPS ATP**RETAIN & GENTLY CLEAN THE FRONT STONE STEPS. REPAINT STONE ON THE SIDES OF THE STEPS TO MATCH ORIGINAL. RETAIN & REPAINT EXISTING METAL RAILING (TRICORN BLACK). RETAIN EXISTING FRONT BASEMENT STEPS AND RAILING. REPAINT EXISTING METAL RAILING (TRICORN BLACK). INSTALL NEW BLACK METAL RAILINGS ON THE SECOND AND THIRD FLOORS OF REAR ELEVATION. SECOND FLOOR RAILING WILL BE INSTALLED IN THE EXISTING MASONRY OPENINGS. INSTALL NEW MATCHING 3RD FLOOR RAILING AROUND THE PERIMETER OF THE SECOND FLOOR ROOFLINE AS PER PLANS ON FILE AND PER CODE. POUR NEW CONCRETE SLAB FOR REAR PARKING PAD AS PER PLANS AND PER CODE IN REAR YARD. REMOVE REAR CHAIN LINK FENCING AND INSTALL NEW VERTICAL BOARD WOOD FENCE AS PER PLANS ALONG PROPERTY REAR PERIMTER. PANELS MEASURING 6FT HIGH X 8 FT WIDE DOG EARED WITH POSTS. REBUILD ROOF FRAMING AS NEEDED AND AS PER CODE TO MATCH. INSTALL NEW TPO, ROLLED RUBBER, OR MODIFIED BITUMEN. THE ROOFLINE WILL RETAIN THE SAME PITCH AS THE HISTORIC ROOFLINE. INSTALL NEW WHITE ALUMINUM HALF-ROUND GUTTERS AND FULL ROUND DOWNSPOUTS ON REAR ROOFLINES. INSTALL NEW INSTALL NEW METAL ROOF COPING WILL MATCH THE SIZE OF THE EXISTING COPING (SIDE AND REAR MASONRY WALLS). RETAIN MASONRY CHIMNEYS ABOVE THE ROOFLINE, REPAIR AND SEAL AS NEEDED. RETAIN, REPAIR AND REPAINT METAL CORNICE. THE CORNICE WILL BE PREPARED FOR PAINTING USING THE GENTLEST MEANS POSSIBLE INCLUDING HAND-SANDING AND HAND-SCRAPING, CLEANING USING THE APPROPRIATE CLEANING AGENT AND WIRE BRUSHING. INSTALL NEW METAL FLASHING ALONG THE TOP OF THE CORNICE TO REPLACE THE EXISTING **SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INSTALL 2X4 FRAMING FOR PARTITION WALLS @ 16 INCHES ON CENTER, REPLACE DRYWALL, TRIM, 8 DOORS, FLOORING, KITCHEN CABINETS, 10 WINDOWS SAME SIZE AND LOCATION. INSTALL 12 X 40 PARKING PAD 4 INCH GRAVEL AND 4 INCH CONCRETE. INSTALL 6 FOOT HIGH WOOD FENCE 110 LINEAR FEET., 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES), AS PER PLANS AND AS PER BALTIMORE CITY CODE, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT PER OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) $14,000Jan 28, 2022
COM2021INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 72000 BTU FUEL-BURNING EQUIP(FURNACE), (14) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # GAS TEST, (1) 50000 BTU FUEL-BURNING EQUIP, (2) 72000 BTU FUEL-BURNING EQUIP AS PER CODE.$8,500Mar 12, 2021

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.