Baltimore City · 21217
916 WHITELOCK ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $182,733
- Land use
- Residential (R)
- Year built
- 1908
- Last sale
- Mar 5, 2013
Assessment
| Owner | URBAN RENAISSANCE MANAGEMENT, LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $182,733 (cycle 2026) |
| Last sale | Mar 5, 2013 — $5,000 |
| Year built | 1908 |
| Zoning | R-8 |
| Vacant | — |
Permits
16| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2020 | USE PREMISES FOR TWO DWELLING UNITS. | — | Jul 21, 2020 |
| COM2020 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2018-74404:SCOPE OF WORK: NON-STRUCTURL ALTERATIONS 2880 SQ. FT. INTERIOR WORK/EXTERIOR WORK: INSTALLING 5 NEW EXTERIOR DOORS, 24 NEW INTERIOR DOORS, 15 NEW WINDOWS, MOULDING, INSULTATION, R38 WALLS AND R49 CEILING, SHEETROCK 2X4 FRAMING 16 OC. ALL WINDOWS AND DOORS TO REMAIN SAME SIZE AND LOCATION. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS.) Original Permit Description:(COM2018-74404) SCOPE OF WORK: NON-STRUCTURL ALTERATIONS 2880 SQ. FT. INTERIOR WORK/EXTERIOR WORK: INSTALLING 5 NEW EXTERIOR DOORS, 24 NEW INTERIOR DOORS, 15 NEW WINDOWS, MOULDING, INSULTATION, R38 WALLS AND R49 CEILING, SHEETROCK 2X4 FRAMING 16 OC. ALL WINDOWS AND DOORS TO REMAIN SAME SIZE AND LOCATION. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. | — | Jul 16, 2020 |
| COM2020 | AMEND PERMIT: CHANGE HVAC CONTRACTOR . REINSTATE (ORIGINAL PERMIT:COM2018-62211:INSTALL (2) 24000 BTU AIR-CON SYSTEM, CONDENSOR, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.) Original Permit Description:(COM2018-62211) INSTALL (2) 24000 BTU AIR-CON SYSTEM, CONDENSOR, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE. | — | Feb 17, 2020 |
| COM2019 | Extend Original Permit.(original permit:COM2018-02433:TO BUILD DECK/FIRE ESCAPE AT REAR OF BUILDING. DECK IS 15.5 FEET LONG AND 8 FEET WIDE. THE DECK SHALL EXTEND IN HEIGHT FROM CONCRETE PAD AT BASEMENT LEVEL TO FLOOR HEIGHT OF THIRD FLOOR. THE TOTAL HEIGHT BEING 26 FEET. THE STAIRS EXTENDING FROM 3RD FLOOR TO 2ND FLOOR AND FROM 2ND FLOOR TO 1ST FLOOR WILL BE WITHIN THE STRUCTURE OF THE DECK. STAIRS WILL BE 3 FEET WIDE WITH 8 INCH RISERS AND 12 INCH THREADS WITH THREE STRINGERS OF 2× 12 TREATED LUMBER. STAIRS FROM FIRST FLOOR TO PAD SHALL BE ATTACHED TO OUTSIDE OF STRUCTURE WITH SAME SPECIFICATION AS ABOVE. THE HEIGHT FROM PAD TO 1ST FLOOR IS 6 FEET. THE DECK WILL BE CONSTRUCTED OF TREATED WOOD USING 8×8 ×24 FEET AS THE MAIN SUPPORT COLUMNS EXTENDING 4 FEET INTO GROUND BELOW CONCRETE PAD AND TO FLOOR OF THIRD FLOOR. STRUCTURE WILL BE ATTACHED TO MAIN BUILDING USING 5/8 THREADED RODS EXTENDING THROUGH REAR BRICK WALL AND ATTACHED TO DOUBLE 2×12 INTERIOR BEAMS USING NUTS AND WASHERS. A RAIL SHALL ENCLOSE PERIMETER OF DECK. HEIGHT OF RAIL WILL BE 40 INCHES WITH BANISTERS 4 INCHES ON CENTER. ) Original Permit Description:(COM2018-02433) TO BUILD DECK/FIRE ESCAPE AT REAR OF BUILDING. DECK IS 15.5 FEET LONG AND 8 FEET WIDE. THE DECK SHALL EXTEND IN HEIGHT FROM CONCRETE PAD AT BASEMENT LEVEL TO FLOOR HEIGHT OF THIRD FLOOR. THE TOTAL HEIGHT BEING 26 FEET. THE STAIRS EXTENDING FROM 3RD FLOOR TO 2ND FLOOR AND FROM 2ND FLOOR TO 1ST FLOOR WILL BE WITHIN THE STRUCTURE OF THE DECK. STAIRS WILL BE 3 FEET WIDE WITH 8 INCH RISERS AND 12 INCH THREADS WITH THREE STRINGERS OF 2× 12 TREATED LUMBER. STAIRS FROM FIRST FLOOR TO PAD SHALL BE ATTACHED TO OUTSIDE OF STRUCTURE WITH SAME SPECIFICATION AS ABOVE. THE HEIGHT FROM PAD TO 1ST FLOOR IS 6 FEET. THE DECK WILL BE CONSTRUCTED OF TREATED WOOD USING 8×8 ×24 FEET AS THE MAIN SUPPORT COLUMNS EXTENDING 4 FEET INTO GROUND BELOW CONCRETE PAD AND TO FLOOR OF THIRD FLOOR. STRUCTURE WILL BE ATTACHED TO MAIN BUILDING USING 5/8 THREADED RODS EXTENDING THROUGH REAR BRICK WALL AND ATTACHED TO DOUBLE 2×12 INTERIOR BEAMS USING NUTS AND WASHERS. A RAIL SHALL ENCLOSE PERIMETER OF DECK. HEIGHT OF RAIL WILL BE 40 INCHES WITH BANISTERS 4 INCHES ON CENTER. | — | Feb 16, 2020 |
| COM2020 | AMEND TO CHANGE ELECTRICAL CONTRACTOR AND REINSTATE: (ORIGINAL PERMIT:COM2019-78021:REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2018-61464:INSTALL (40) # BRANCH CIRCUITS/FEEDERS , (2) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (16) # LOW VOLTAGE AS PER CODE.)) Original Permit Description:(COM2019-78021) REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2018-61464:INSTALL (40) # BRANCH CIRCUITS/FEEDERS , (2) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (16) # LOW VOLTAGE AS PER CODE.) | — | Feb 14, 2020 |
| COM2020 | AMEND PERMIT: CHANGE PLUMBING CONTRACTOR . REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-78023:REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2017-66607:INSTALL (23) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 70000 BTU FUEL-BURNING EQUIP, (2) 200000 BTU FUEL-BURNING EQUIP, (2) 100000 BTU FUEL-BURNING EQUIP AS PER CODE.)) Original Permit Description:(COM2019-78023) REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2017-66607:INSTALL (23) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 70000 BTU FUEL-BURNING EQUIP, (2) 200000 BTU FUEL-BURNING EQUIP, (2) 100000 BTU FUEL-BURNING EQUIP AS PER CODE.) | — | Feb 14, 2020 |
| COM2020 | AMEND PERMIT: CHANGE HVAC CONTRACTOR . REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2018-62211:INSTALL (2) 24000 BTU AIR-CON SYSTEM, CONDENSOR, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.) Original Permit Description:(COM2018-62211) INSTALL (2) 24000 BTU AIR-CON SYSTEM, CONDENSOR, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE. | — | Feb 14, 2020 |
| COM2019 | reinstate original permit.(original permit:com2019-77788:reinstate original permit.(original permit:com2018-74404:scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings.) original permit description:(com2018-74404) scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings.) original permit description:(com2019-77788) reinstate original permit.(original permit:com2018-74404:scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings.) original permit description:(com2018-74404) scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings. | — | Nov 18, 2019 |
| COM2019 | reinstate original permit.(original permit:com2018-62211:install (2) 24000 btu air-con system, condensor, (2) # new distribution system (1-2 family), (2) 80000 btu fuel-burning equip(furnace) as per code.) original permit description:(com2018-62211) install (2) 24000 btu air-con system, condensor, (2) # new distribution system (1-2 family), (2) 80000 btu fuel-burning equip(furnace) as per code. | — | Sep 24, 2019 |
| COM2019 | reinstate original permit.(original permit:com2017-66607:install (23) # plumbing fixtures, (1) # sanitary connection (reconstruction0, (1) # water service pipe (reconstruction), (2) 70000 btu fuel-burning equip, (2) 200000 btu fuel-burning equip, (2) 100000 btu fuel-burning equip as per code.) | — | Sep 19, 2019 |
| COM2019 | reinstate original permit.(original permit:com2018-61464:install (40) # branch circuits/feeders , (2) 100 amps electric service up to 600v (#amps), (16) # low voltage as per code.) | — | Sep 19, 2019 |
| COM2019 | reinstate original permit.(original permit:com2018-74404:scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings.) original permit description:(com2018-74404) scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings. | — | Sep 17, 2019 |
| COM2019 | scope of work: exterior alterations to include: cut and re-point porch bricks. no ladder or scaffold required. all work will be done according to baltimore city code. | $1,000 | Aug 15, 2019 |
| COM2019 | extend:(original permit:com2018-02433:to build deck/fire escape at rear of building. deck is 15.5 feet long and 8 feet wide. the deck shall extend in height from concrete pad at basement level to floor height of third floor. the total height being 26 feet. the stairs extending from 3rd floor to 2nd floor and from 2nd floor to 1st floor will be within the structure of the deck. stairs will be 3 feet wide with 8 inch risers and 12 inch threads with three stringers of 2× 12 treated lumber. stairs from first floor to pad shall be attached to outside of structure with same specification as above. the height from pad to 1st floor is 6 feet. the deck will be constructed of treated wood using 8×8 ×24 feet as the main support columns extending 4 feet into ground below concrete pad and to floor of third floor. structure will be attached to main building using 5/8 threaded rods extending through rear brick wall and attached to double 2×12 interior beams using nuts and washers. a rail shall enclose perimeter of deck. height of rail will be 40 inches with banisters 4 inches on center. ) original permit description:(com2018-02433) to build deck/fire escape at rear of building. deck is 15.5 feet long and 8 feet wide. the deck shall extend in height from concrete pad at basement level to floor height of third floor. the total height being 26 feet. the stairs extending from 3rd floor to 2nd floor and from 2nd floor to 1st floor will be within the structure of the deck. stairs will be 3 feet wide with 8 inch risers and 12 inch threads with three stringers of 2× 12 treated lumber. stairs from first floor to pad shall be attached to outside of structure with same specification as above. the height from pad to 1st floor is 6 feet. the deck will be constructed of treated wood using 8×8 ×24 feet as the main support columns extending 4 feet into ground below concrete pad and to floor of third floor. structure will be attached to main building using 5/8 threaded rods extending through rear brick wall and attached to double 2×12 interior beams using nuts and washers. a rail shall enclose perimeter of deck. height of rail will be 40 inches with banisters 4 inches on center. | — | May 7, 2019 |
| COM2019 | extend:(original permit:com2018-83826: extend original permit.(original permit:com2018-61464:install (40) # branch circuits/feeders , (2) 100 amps electric service up to 600v (#amps), (16) # low voltage as per code.) original permit description:(com2018-61464) install (40) # branch circuits/feeders , (2) 100 amps electric service up to 600v (#amps), (16) # low voltage as per code.) original permit description:(com2018-83826) extend original permit.(original permit:com2018-61464:install (40) # branch circuits/feeders , (2) 100 amps electric service up to 600v (#amps), (16) # low voltage as per code.) original permit description:(com2018-61464) install (40) # branch circuits/feeders , (2) 100 amps electric service up to 600v (#amps), (16) # low voltage as per code. | — | Mar 19, 2019 |
| COM2019 | extend original permit.(original permit:com2018-74404:scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings.) original permit description:(com2018-74404) scope of work: non-structurl alterations 2880 sq. ft. interior work/exterior work: installing 5 new exterior doors, 24 new interior doors, 15 new windows, moulding, insultation, r38 walls and r49 ceiling, sheetrock 2x4 framing 16 oc. all windows and doors to remain same size and location. all work will be done according to baltimore city code and per submitted drawings. | — | Jan 3, 2019 |
Violations
3| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| citation | PM 306.1 | O | $50 | $50 | Jun 1, 2026 |
| service_request | HCD-Sanitation Property | Closed | — | — | May 15, 2026 |
| service_request | HCD-Maintenance Structure | Closed | — | — | May 9, 2026 |
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 9, 2026 · 54 m · 2410 LAKEVIEW AVE
- violation: HCD-Sanitation PropertyJul 7, 2026 · 80 m · 2407 LAKEVIEW AVE
- permit: BUSEJul 7, 2026 · 87 m · 813 WHITELOCK ST
- violation: HCD-Sanitation PropertyJul 6, 2026 · 102 m · 2432 LAKEVIEW AVE
- violation: VacantJul 6, 2026 · 127 m · 2515 BROOKFIELD AVE
- violation: HCD-Vacant BuildingJul 6, 2026 · 131 m · 2508 BROOKFIELD AVE
- violation: VacantJul 6, 2026 · 132 m · 2517 BROOKFIELD AVE
- violation: VacantJul 6, 2026 · 137 m · 2519 BROOKFIELD AVE
- violation: SW-Dirty AlleyJul 4, 2026 · 85 m · 811 WHITELOCK ST
- violation: SW-Dirty AlleyJul 4, 2026 · 96 m · 807 WHITELOCK ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.