Permits

16
TypeDescriptionCostIssued
USE2021USE AS A SINGLE-FAMILY DWELLING. Dec 22, 2021
COM2021SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: INSTALLATION OF SMALL LANDING/DECK WITH STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), FROM REAR DINING ROOM TO BACKYARD BOARD AND BATTEN FENCE WITH GATE, (FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS), PAVE PATIO GRADING TO ALLEY WITH PERMEABLE STONE, INSTALL PARKING PAD WITH RIVER ROCK BEDS AS PER PLANS AS CODE. SEPARATE PERMIT WILL BE REQUIRED FOR ALL MEP WORK. (*NOTES: 1. ALL FENCING, DECK, PARKING PAD AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES, 2. DECK WILL BE PROPERLY SECURED) $20,000Oct 4, 2021
COM2021REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2020-52869:INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.) Original Permit Description:(COM2020-52869) INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.Aug 18, 2021
COM2021 Extend Original Permit.(original permit:COM2020-54459:INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2020-54459) INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.Jul 27, 2021
COM2021 Extend Original Permit.(original permit:COM2019-68792:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERS) Original Permit Description:(COM2019-68792) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERSJun 29, 2021
COM2021 Extend Original Permit.(original permit:COM2020-54459:INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2020-54459) INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.Feb 9, 2021
COM2020 Extend Original Permit.(original permit:COM2019-68792:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERS) Original Permit Description:(COM2019-68792) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERSJan 5, 2021
COM2020REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2019-86799:INSTALL (7) 230000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP, (19) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR AS PER CODE.) Original Permit Description:(COM2019-86799) INSTALL (7) 230000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP, (19) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR AS PER CODE.Oct 11, 2020
COM2020 Extend Original Permit.(original permit:COM2020-54459:INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2020-54459) INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.Jul 29, 2020
COM2020 Extend Original Permit.(original permit:COM2019-68792:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERS) Original Permit Description:(COM2019-68792) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: SISTER ROOF JOIST. REPLACE 3RD FLOOR SKYLIGHT (SAME SIZE AND LOCATION), CONVERT 1- 3RD FLOOR EAST WINDOW TO A DOOR TO DECK. FRAME 3RD FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS, R-49 ROOF INSULATION, R-21 EXTERIOR WALL INSULATION THROUGHOUT ENTIRE HOUSE. FRAME 2ND. FLOOR REAR ROOF AS PER PLANS. FRAME 2ND FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. FRAME 1ST FLOOR NON LOAD BEARING PARTITIONS AS PER PLANS. INSULATE BASEMENT EXTERIOR WALLS USING R-13. REPLACE 10 REAR WINDOWS. REPLACE 3 REAR EXTERIOR DOORS. INSTALL DRYWALL. INSTALL NEW INTERIOR TRIM. REMOVAL OF REAR FIRE ESCAPE (FIRE ESCAPE IS REMOVAL ONLY/SEPARATE PERMIT WILL BE REQUIRED TO RECONSTRUCT FIRE ESCAPE), REPOINTING OF NORTH AND WEST EXTERIOR WALL, REPLACEMENT OF 10 WINDOWS (IN THE SAME SIZE AND LOCATION), REPLACEMENT OF EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), SECOND FLOOR REAR ROOF TO BE REFRAMED AS PER DRAWINGS WITH A 1/4'' PER FOOT SLOPE TO THE WEST TO PROVIDE A WALKABLE ROOFTOP SURFACE ON WHICH TO INSTALL A WALKABLE ROOF MEMBRANE TO SERVE AS A DECK SURFACE, INSTALL 140 LINEAR FEET OF 6' HIGH WOOD FENCING ALONG THE PROPERTY, PAVE A REAR PARKING PAD USING 6'' CONCRETE AND 4'' GRAVEL, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED DRAWINGS. PLUMBING, MECHANICAL, AND ELECTRICAL BY OTHERSJun 18, 2020
COM2020INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 400 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (1) 400 AMPS ENLARGE ELECTRICAL METERS, (1) 400 AMPS EXISTING ELECTRICAL METERS, (30) # FIXTURES/DEVICES AS PER CODE.$30,000Feb 11, 2020
COM2020INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.$32,800Jan 28, 2020
COM2019INSTALL (7) 230000 BTU FUEL-BURNING EQUIP, (1) 60000 BTU FUEL-BURNING EQUIP, (19) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR AS PER CODE.$15,000Jan 12, 2020
COM2019 extend original permit.(original permit:com2019-68792:scope of work: interior/exterior alterations to include: sister roof joist. replace 3rd floor skylight (same size and location), convert 1- 3rd floor east window to a door to deck. frame 3rd floor non load bearing partitions as per plans, r-49 roof insulation, r-21 exterior wall insulation throughout entire house. frame 2nd. floor rear roof as per plans. frame 2nd floor non load bearing partitions as per plans. frame 1st floor non load bearing partitions as per plans. insulate basement exterior walls using r-13. replace 10 rear windows. replace 3 rear exterior doors. install drywall. install new interior trim. removal of rear fire escape (fire escape is removal only/separate permit will be required to reconstruct fire escape), repointing of north and west exterior wall, replacement of 10 windows (in the same size and location), replacement of exterior staircase (tread: 9"min, rise: 8 1/4"max, and width: 36"min), second floor rear roof to be reframed as per drawings with a 1/4" per foot slope to the west to provide a walkable rooftop surface on which to install a walkable roof membrane to serve as a deck surface, install 140 linear feet of 6' high wood fencing along the property, pave a rear parking pad using 6" concrete and 4" gravel, all work will be done according to baltimore city code and per submitted drawings. plumbing, mechanical, and electrical by others) original permit description:(com2019-68792) scope of work: interior/exterior alterations to include: sister roof joist. replace 3rd floor skylight (same size and location), convert 1- 3rd floor east window to a door to deck. frame 3rd floor non load bearing partitions as per plans, r-49 roof insulation, r-21 exterior wall insulation throughout entire house. frame 2nd. floor rear roof as per plans. frame 2nd floor non load bearing partitions as per plans. frame 1st floor non load bearing partitions as per plans. insulate basement exterior walls using r-13. replace 10 rear windows. replace 3 rear exterior doors. install drywall. install new interior trim. removal of rear fire escape (fire escape is removal only/separate permit will be required to reconstruct fire escape), repointing of north and west exterior wall, replacement of 10 windows (in the same size and location), replacement of exterior staircase (tread: 9"min, rise: 8 1/4"max, and width: 36"min), second floor rear roof to be reframed as per drawings with a 1/4" per foot slope to the west to provide a walkable rooftop surface on which to install a walkable roof membrane to serve as a deck surface, install 140 linear feet of 6' high wood fencing along the property, pave a rear parking pad using 6" concrete and 4" gravel, all work will be done according to baltimore city code and per submitted drawings. plumbing, mechanical, and electrical by othersDec 24, 2019
COM2019scope of work: interior/exterior alterations to include: sister roof joist. replace 3rd floor skylight (same size and location), convert 1- 3rd floor east window to a door to deck. frame 3rd floor non load bearing partitions as per plans, r-49 roof insulation, r-21 exterior wall insulation throughout entire house. frame 2nd. floor rear roof as per plans. frame 2nd floor non load bearing partitions as per plans. frame 1st floor non load bearing partitions as per plans. insulate basement exterior walls using r-13. replace 10 rear windows. replace 3 rear exterior doors. install drywall. install new interior trim. removal of rear fire escape (fire escape is removal only/separate permit will be required to reconstruct fire escape), repointing of north and west exterior wall, replacement of 10 windows (in the same size and location), replacement of exterior staircase (tread: 9"min, rise: 8 1/4"max, and width: 36"min), second floor rear roof to be reframed as per drawings with a 1/4" per foot slope to the west to provide a walkable rooftop surface on which to install a walkable roof membrane to serve as a deck surface, install 140 linear feet of 6' high wood fencing along the property, pave a rear parking pad using 6" concrete and 4" gravel, all work will be done according to baltimore city code and per submitted drawings. plumbing, mechanical, and electrical by others$350,000Jun 28, 2019
COM2019scope of work: interior alterations to include: interior demolition (category i): remove drywall, plaster, non-original trim, non-original floor coverings, and non-load bearing interior partitions. protect original staircase and handrail system. protect exposed original hardwood floors, all work will be done according to baltimore city code. demo only, separate permit will be pulled/required for interior renovations. $20,000Mar 1, 2019

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;