Baltimore City · 21211

3311 CHESTNUT AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$313,933
Land use
Residential (R)
Year built
1880
Last sale
Feb 7, 2023

Assessment

OwnerSHORTALL JR, JOSEPH
Land useResidential (R)
Total assessment$313,933 (cycle 2026)
Last saleFeb 7, 2023 — $420,000
Year built1880
ZoningR-6
Vacant

Permits

9
TypeDescriptionCostIssued
USE2022USE AS A SINGLE FAMILY DWELLINGAug 8, 2022
COM2022 Extend Original Permit.(original permit:COM2021-85964:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE.) Original Permit Description:(COM2021-85964) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE.Jun 21, 2022
COM2022 Extend Original Permit.(original permit:COM2021-01330:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS, DEMO EXISTING 1ST FLOOR REAR ADDITION. DEMO 2ND & 3RD FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS, NEW INTERIOR WORK: FRAMING (1,600 SF) W/ STUD WALLS, STAIRCASE (7-/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF) DOORS (15) DEMO/REPOUR EXISTING BASEMENT SLAB (10'-1''X27')(276 SF) NEW EXTERIOR WORK: NEW 1ST FLOOR ADDITION (12'X17'-4'') (208 SF) NEW 2ND FLOOR REAR ADDITION (12'X30'-3'')(363 SF), NEW 3RD FLOOR REAR ADDITION (12'X22'-9'') (273 SF) NEW 3RD FLOOR REAR WALKABLE ROOF TERRACE (12'X7'-6'') NEW EXTERIOR DOORS (3) WINDOWS (12) NEW REAR CONCRETE SLAB (12'X40')(480 SF) AS PER PLANS AS PER CODE. SEPERATE PERMITS ARE REQUIRED FOR EMP WORK. ) Original Permit Description:(COM2021-01330) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS, DEMO EXISTING 1ST FLOOR REAR ADDITION. DEMO 2ND & 3RD FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS, NEW INTERIOR WORK: FRAMING (1,600 SF) W/ STUD WALLS, STAIRCASE (7-/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF) DOORS (15) DEMO/REPOUR EXISTING BASEMENT SLAB (10'-1''X27')(276 SF) NEW EXTERIOR WORK: NEW 1ST FLOOR ADDITION (12'X17'-4'') (208 SF) NEW 2ND FLOOR REAR ADDITION (12'X30'-3'')(363 SF), NEW 3RD FLOOR REAR ADDITION (12'X22'-9'') (273 SF) NEW 3RD FLOOR REAR WALKABLE ROOF TERRACE (12'X7'-6'') NEW EXTERIOR DOORS (3) WINDOWS (12) NEW REAR CONCRETE SLAB (12'X40')(480 SF) AS PER PLANS AS PER CODE. SEPERATE PERMITS ARE REQUIRED FOR EMP WORK. Jun 10, 2022
COM2022INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$15,000Jun 6, 2022
COM2022SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: FENCING INSTALLATION, INSTALL NEW 6' P.T. WOOD FENCE IN REAR YARD, 42 LINEAR FT. AS PER SKETCH, AS PER CODE (*NOTES: 1. ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES).$2,000Mar 7, 2022
COM2021INSTALL (3) # PLUMBING FIXTURES, (3) # PLUMBING FIXTURES, (2) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # PLUMBING FIXTURES, (1) # PLUMBING FIXTURES, (2) 80000 BTU FUEL-BURNING EQUIP, (1) 50000 BTU FUEL-BURNING EQUIP, (1) # SANITARY CONNECTION (1-2 FAM. RES.), (1) # WATER SERVICE PIPE ( 1-2 FAM. RES.) AS PER CODE.$1,000Dec 30, 2021
COM2021INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS AS PER CODE.$1,500Dec 1, 2021
COM2021INSTALL (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$15,000Nov 18, 2021
COM2021INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS, DEMO EXISTING 1ST FLOOR REAR ADDITION. DEMO 2ND & 3RD FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS, NEW INTERIOR WORK: FRAMING (1,600 SF) W/ STUD WALLS, STAIRCASE (7-/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF) DOORS (15) DEMO/REPOUR EXISTING BASEMENT SLAB (10'-1''X27')(276 SF) NEW EXTERIOR WORK: NEW 1ST FLOOR ADDITION (12'X17'-4'') (208 SF) NEW 2ND FLOOR REAR ADDITION (12'X30'-3'')(363 SF), NEW 3RD FLOOR REAR ADDITION (12'X22'-9'') (273 SF) NEW 3RD FLOOR REAR WALKABLE ROOF TERRACE (12'X7'-6'') NEW EXTERIOR DOORS (3) WINDOWS (12) NEW REAR CONCRETE SLAB (12'X40')(480 SF) AS PER PLANS AS PER CODE. SEPERATE PERMITS ARE REQUIRED FOR EMP WORK. $100,000Jun 16, 2021

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.