Baltimore City · 21211
3532 ROLAND AVE
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $368,333
- Land use
- Residential (R)
- Year built
- 1900
- Last sale
- Jan 24, 2024
Assessment
| Owner | VINCENT, AMANDA LYNN |
|---|---|
| Land use | Residential (R) |
| Total assessment | $368,333 (cycle 2026) |
| Last sale | Jan 24, 2024 — $439,000 |
| Year built | 1900 |
| Zoning | R-7 |
| Vacant | — |
Permits
8| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-72256:INSTALL (1) 60 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (11) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (2) 60 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2022-72256) INSTALL (1) 60 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (11) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (2) 60 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Dec 8, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-72256:INSTALL (1) 60 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (11) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (2) 60 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2022-72256) INSTALL (1) 60 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (11) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (2) 60 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Oct 12, 2023 |
| COM2022 | Extend Original Permit.(original permit:COM2022-60668: INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW EXTERIOR DOORS (2), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ.FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) ) Original Permit Description:(COM2022-60668) INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW EXTERIOR DOORS (2), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ.FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | — | Oct 27, 2022 |
| COM2022 | SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: REMOVE DAMAGED PLASTER, REPAIR DRYWALL AND INSTALL NEW AS NEEDED, PAINT HOME, INSTALL NEW CABINETS, INSTALL NEW TILE FOR BATHROOMS, INSTALL NEW FLOORING, INSTALL NEW INTERIOR DOOR AND TRIM, REPLACE DAMAGED WINDOWS. *DOOR AND WINDOWS IN THE SAME SIZE AND LOCATION, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE | $50,000 | Oct 22, 2022 |
| COM2022 | INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 60000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | $4,000 | Aug 26, 2022 |
| COM2022 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (15) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | $2,000 | Jun 30, 2022 |
| COM2022 | INSTALL (1) 60 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (11) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # GAS TEST, (2) 60 BTU FUEL-BURNING EQUIP AS PER CODE. | $9,000 | Jun 28, 2022 |
| COM2022 | INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW EXTERIOR DOORS (2), WINDOWS (11). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ.FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | $60,000 | Mar 30, 2022 |
Violations
2| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| citation | HE 10-313 | O | $200 | $600 | Jul 10, 2017 |
| citation | HE 10-313 | O | $200 | $600 | Jun 23, 2017 |
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-CCE Building Permit ComplaintJul 8, 2026 · 53 m · 3529 HICKORY AVE
- permit: BRCMJul 8, 2026 · 61 m · 3519 ROLAND AVE
- permit: BRCMJul 8, 2026 · 128 m · 3521 FALLS RD
- permit: BRCMJul 7, 2026 · 146 m · 3440 ELM AVE
- violation: HCD-Maintenance StructureJul 6, 2026 · 141 m · 903 W 36TH ST
- violation: HCD-CCE Building InspectionsJul 6, 2026 · 141 m · 903 W 36TH ST
- permit: BRCMJul 1, 2026 · 88 m · 3534 HICKORY AVE
- violation: HCD-Maintenance StructureJun 30, 2026 · 40 m · 3515 HICKORY AVE
- violation: BC 123.8.2Jun 30, 2026 · 68 m · 1013 W 36TH ST
- violation: BC 123.8.2Jun 30, 2026 · 81 m · 1025 W 36TH ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.