Assessment
| Owner | HYSON, MARY E |
|---|---|
| Land use | Residential (R) |
| Total assessment | $279,700 (cycle 2026) |
| Last sale | Aug 25, 2023 — $285,000 |
| Year built | 1916 |
| Zoning | R-6 |
| Vacant | — |
Permits
13| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-84909:INSTALL (1) 30000 BTU FUEL-BURNING EQUIP(STOVE/RANGE), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 50 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-84909) INSTALL (1) 30000 BTU FUEL-BURNING EQUIP(STOVE/RANGE), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 50 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Jun 26, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-84702:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (25) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2021-84702) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (25) # LOW VOLTAGE AS PER CODE. | — | Jun 21, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-84702:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (25) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2021-84702) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (25) # LOW VOLTAGE AS PER CODE. | — | Jan 24, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-51163:INSTALL (24) # BRANCH CIRCUITS/FEEDERS AS PER CODE.) Original Permit Description:(COM2022-51163) INSTALL (24) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | — | Jan 24, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-74120:SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: CATEGORY I-NON-STRUCTURAL DEMO ONLY 836 SQ FT NON-STRUCTURAL DEMOLITION (INCLUDES THE REMOVAL OF PLASTER, DRYWALL, INTERIOR DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, SEPARATE PERMIT WILL BE PULLED FOR ANY INTERIOR RENOVATIONS/TENANT FITOUT) Original Permit Description:(COM2021-74120) SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: CATEGORY I-NON-STRUCTURAL DEMO ONLY 836 SQ FT NON-STRUCTURAL DEMOLITION (INCLUDES THE REMOVAL OF PLASTER, DRYWALL, INTERIOR DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, SEPARATE PERMIT WILL BE PULLED FOR ANY INTERIOR RENOVATIONS/TENANT FITOUT | — | Jan 24, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-86128:NON=STRUCTURAL/STRUCTURAL ALTERATIONS - 1236 SQ FT - FRAMING 2X4 @ 16 O.C.; DRYWALL, TRIM, BASEBOARD; NEW 2ND 8X10 ADDITION AS PER SKETCH; REPLACE 1ST FLOOR REAR DECK PORCH 11-9X8; REPLACE JOIST 2X8 AND BEAMS 2X10 AND NEW STAIRS AS PER SKETCH (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN); R21 INSULATION FOR WALLS AND R49 INSULATION FOR CEILINGS; REPLACE DRIVEWAY IN REAR 4'' GRAVEL AND 6'' CONCRETE ON EXISTING APRON AS PER SKETCH (80SQ/FT); REPLACE 15 WINDOWS; 3 EXTERIOR DOORS; 10 INTERIOR DOORS; WINDOWS AND DOORS SAME SIZE AND LOCATION; REPLACE EXISTING 4FT CHAINLINK FENCE WITH NEW 4' CHAIN LINK FENCE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) AS PER CODE AS PER SKETCHES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL DECK, FOOTER, AND ADDITION WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS)) Original Permit Description:(COM2021-86128) NON=STRUCTURAL/STRUCTURAL ALTERATIONS - 1236 SQ FT - FRAMING 2X4 @ 16 O.C.; DRYWALL, TRIM, BASEBOARD; NEW 2ND 8X10 ADDITION AS PER SKETCH; REPLACE 1ST FLOOR REAR DECK PORCH 11-9X8; REPLACE JOIST 2X8 AND BEAMS 2X10 AND NEW STAIRS AS PER SKETCH (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN); R21 INSULATION FOR WALLS AND R49 INSULATION FOR CEILINGS; REPLACE DRIVEWAY IN REAR 4'' GRAVEL AND 6'' CONCRETE ON EXISTING APRON AS PER SKETCH (80SQ/FT); REPLACE 15 WINDOWS; 3 EXTERIOR DOORS; 10 INTERIOR DOORS; WINDOWS AND DOORS SAME SIZE AND LOCATION; REPLACE EXISTING 4FT CHAINLINK FENCE WITH NEW 4' CHAIN LINK FENCE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) AS PER CODE AS PER SKETCHES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL DECK, FOOTER, AND ADDITION WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) | — | Jan 17, 2023 |
| COM2023 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-84909:INSTALL (1) 30000 BTU FUEL-BURNING EQUIP(STOVE/RANGE), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 50 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-84909) INSTALL (1) 30000 BTU FUEL-BURNING EQUIP(STOVE/RANGE), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 50 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Jan 17, 2023 |
| COM2022 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 90000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 60 CFM EXHAUST SYSTEMS AS PER CODE. | $9,500 | Dec 10, 2022 |
| COM2022 | INSTALL (24) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | $1,500 | Jan 7, 2022 |
| COM2021 | NON=STRUCTURAL/STRUCTURAL ALTERATIONS - 1236 SQ FT - FRAMING 2X4 @ 16 O.C.; DRYWALL, TRIM, BASEBOARD; NEW 2ND 8X10 ADDITION AS PER SKETCH; REPLACE 1ST FLOOR REAR DECK PORCH 11-9X8; REPLACE JOIST 2X8 AND BEAMS 2X10 AND NEW STAIRS AS PER SKETCH (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN); R21 INSULATION FOR WALLS AND R49 INSULATION FOR CEILINGS; REPLACE DRIVEWAY IN REAR 4'' GRAVEL AND 6'' CONCRETE ON EXISTING APRON AS PER SKETCH (80SQ/FT); REPLACE 15 WINDOWS; 3 EXTERIOR DOORS; 10 INTERIOR DOORS; WINDOWS AND DOORS SAME SIZE AND LOCATION; REPLACE EXISTING 4FT CHAINLINK FENCE WITH NEW 4' CHAIN LINK FENCE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) AS PER CODE AS PER SKETCHES. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT PER ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL DECK, FOOTER, AND ADDITION WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN ALL PROPER SETBACKS) | $25,000 | Dec 3, 2021 |
| COM2021 | INSTALL (1) 30000 BTU FUEL-BURNING EQUIP(STOVE/RANGE), (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 50 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (10) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | $9,800 | Nov 16, 2021 |
| COM2021 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # FIXTURES/DEVICES, (25) # LOW VOLTAGE AS PER CODE. | $4,600 | Nov 12, 2021 |
| COM2021 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: CATEGORY I-NON-STRUCTURAL DEMO ONLY 836 SQ FT NON-STRUCTURAL DEMOLITION (INCLUDES THE REMOVAL OF PLASTER, DRYWALL, INTERIOR DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, *THIS PERMIT IS FOR INTERIOR DEMOLITION ONLY, SEPARATE PERMIT WILL BE PULLED FOR ANY INTERIOR RENOVATIONS/TENANT FITOUT | $5,500 | Aug 11, 2021 |
Violations
1| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| citation | PM 305.2.2 | O | $50 | $150 | Aug 29, 2018 |
Inspections
1| Type | Status |
|---|---|
| InitialECB | OPEN |
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 6, 2026 · 104 m
- permit: BRCMJun 29, 2026 · 36 m · 2119 N LONGWOOD ST
- violation: SW-Dirty AlleyJun 29, 2026 · 44 m · 2918 WINDSOR AVE
- violation: HCD-Sanitation PropertyJun 29, 2026 · 57 m
- violation: HCD-Sanitation PropertyJun 26, 2026 · 81 m
- violation: SW-Dirty AlleyJun 26, 2026 · 97 m
- violation: PM 306.2Jun 22, 2026 · 147 m · 3019 POPLAR TERR
- violation: PM 305.2.2Jun 22, 2026 · 147 m · 3019 POPLAR TERR
- violation: HCD-Sanitation PropertyJun 19, 2026 · 146 m
- violation: PM 305.2.2Jun 16, 2026 · 78 m · 2919 WINDSOR AVE