Baltimore City · 21217

1728 N FULTON AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$25,667
Land use
Residential (R)
Year built
1920
Last sale
May 14, 2026

Assessment

OwnerLSN INVESTMENTS LLC
Land useResidential (R)
Total assessment$25,667 (cycle 2026)
Last saleMay 14, 2026 — $22,000
Year built1920
ZoningR-7
VacantYes

Permits

3
TypeDescriptionCostIssued
BRCMInstallation of new ductwork , new 3.5 ton heat pump system , 4 exhaust fans and 1 dryer exhaust vent$16,500Jul 6, 2026
BRCMRenovation of Existing Three-Story Single-Family Rowhouse For 4 Bed/4.5 Bath No change in occupancy. No underpinning proposed. Majority of existing structural framing to remain unless specifically noted below. Separate trade permits (Electrical, Mechanical, and Plumbing) will be pulled by licensed trade contractors. INTERIOR ALTERATIONS 1. Demolition • Category II interior demolition. • No demolition of existing structural bearing walls unless specifically noted. 2. Structural Floor Framing • Remove and replace deteriorated floor joists as required. • Install new 2” x 8” wood floor joists @ 16” O.C., bearing in existing masonry joist pockets. • Provide proper end bearing per IRC requirements. • Install approved Simpson Strong-Tie connectors at joist-to-wall and joist-to-framing connections where applicable. • Install new ¾” OSB subfloor, screwed to new joists. 3. Basement Work (No Underpinning) • Install interior drain tile system inside basement perimeter walls. • Basement shall be finished for storage only. 4. Stairs • New code-compliant stairs proposed all floors. • Install new code-compliant handrails and guardrails as required. 5. Interior Framing • Frame approximately 400 SF of new interior partition walls using 2” x 4” wood studs @ 16” O.C. • Provide required blocking for casework, vanities, shelving, and fixtures. 6. Insulation • Install R-38 batt insulation at roof/ceiling level. • Install R-21 batt insulation in new exterior framed walls. • Install R-15 batt insulation at furred masonry front wall. 7. Gypsum Board & Wall Assemblies Where required we will install as follows: • Standard interior walls and ceiling infill: ½” gypsum wallboard (GWB). • Bathroom and kitchen wet walls: ½” moisture-resistant GWB. • Tile and backsplash areas: ½” cement board (Durock). • Install vapor barrier at insulated bearing wall assemblies where required by code. • Fire-caulk all required rated penetrations. ? EXTERIOR ALTERATIONS 1. Exterior Wall Framing (Where Applicable) • Any new exterior framed walls shall use 2” x 6” wood studs @ 16” O.C. • Any repaired exterior walls shall Install ½” exterior-grade plywood sheathing and weather-resistive barrier (Tyvek or approved equal). • We’re applicable exterior finish where repaired: vinyl siding 2. Roof Replacement • Remove existing roofing materials down to deck. • Demolish and replace any damaged roof joists • Where required to repair/replace damage joists o Install new 2” x 8” roof joists @ 16” O.C. ? Roof joists to bear in existing masonry pockets and/or approved bearing assemblies. ? Provide required lateral bracing and ties per IRC. • Replace roof decking as required with ½” plywood sheathing, fastened per code. • Install new 2-ply torch-down modified bitumen roofing system. 3. Gutters • Install 5” aluminum K-style gutters with 3” x 4” downspouts discharging to on-grade splash blocks. 4. Windows • Remove and replace fourteen (14) vinyl windows, same size and same location. • Installation to comply with current IRC egress and flashing requirements. 5. Exterior Doors • Install two (2) new pre-hung insulated exterior doors, installed per manufacturer specifications and code. all work will be done according to Baltimore city code and per submitted plans. Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance.$30,000Jun 4, 2026
COM2019scope of work: interior alterations to include: interior demolition (category i): demo 700 sq feet of non structural walls and ceilings, flooring as per code demo only, separate permit will be pulled/required for interior renovations.$500Apr 11, 2019

Violations

4
KindCategoryStatusFineBalanceDate
citationBC 123.8.1P$1,000$0Feb 3, 2026
citationBC 123.8.1P$1,000$0Apr 24, 2025
citationBC 123.8.1P$1,000$0Mar 5, 2024
vacant_building_noticeVacantopenDec 3, 2017

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.