Assessment
| Owner | HOPE BLUEPRINT DEVELOPMENT |
|---|---|
| Land use | Residential (R) |
| Total assessment | $16,400 (cycle 2026) |
| Last sale | Mar 11, 2026 — $25,000 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | Yes |
Permits
3| Type | Description | Cost | Issued |
|---|---|---|---|
| BRCM | INSTALL 200 AMP SERVICE AND 23 CIRCUITS , INSTALL 14 PLUMBING FIXTURES,1 ELECTRIC HOT WATER TANK, WASTE AND WATER RECONSTRUCTION , 1 SUMP PUMP | $7,200 | May 20, 2026 |
| BRCM | New Hvac System Installation 3.5 Heatpump System 4 Exhaust Fans | $12,000 | Apr 30, 2026 |
| BRCM | Renovation of Existing Two-Story Single-Family Rowhouse with Existing 7’-0” Basement (No Underpinning Required). No change in occupancy. No underpinning proposed. Majority of existing structural framing to remain unless specifically noted below. Separate trade permits (Electrical, Mechanical, and Plumbing) will be pulled by licensed trade contractors. INTERIOR ALTERATIONS 1. Demolition • Category I interior demolition of non-load-bearing partition walls. • No demolition of existing structural bearing walls unless specifically noted. 2. Structural Floor Framing • Remove and replace deteriorated floor joists as required. • Install new 2” x 8” wood floor joists @ 16” O.C., bearing in existing masonry joist pockets. • Provide proper end bearing per IRC requirements. • Install approved Simpson Strong-Tie connectors at joist-to-wall and joist-to-framing connections where applicable. • Install new ¾” OSB subfloor, screwed to new joists. 3. Basement Work (No Underpinning) • Install interior drain tile system inside basement perimeter walls. • Existing 7’-0” basement height to remain; no underpinning proposed. 4. Stairs • Existing stair framing to remain. • Install new code-compliant handrails and guardrails as required. 5. Interior Framing • Frame approximately 200 SF of new interior partition walls using 2” x 4” wood studs @ 16” O.C. • Provide required blocking for casework, vanities, shelving, and fixtures. 6. Insulation • Install R-38 batt insulation at roof/ceiling level. • Install R-21 batt insulation in new exterior framed walls. • Install R-15 batt insulation at furred masonry front wall. 7. Gypsum Board & Wall Assemblies Majority of existing drywall to remain however where required we will install as follows: • Standard interior walls and ceiling infill: ½” gypsum wallboard (GWB). • Bathroom and kitchen wet walls: ½” moisture-resistant GWB. • Tile and backsplash areas: ½” cement board (Durock). • Install vapor barrier at insulated bearing wall assemblies where required by code. • Fire-caulk all required rated penetrations. EXTERIOR ALTERATIONS 1. Exterior Wall Framing (Where Applicable) • Repair 150 SF of exterior brick on the alley way side of property. • Any new exterior framed walls shall use 2” x 6” wood studs @ 16” O.C. • Any repaired exterior walls shall Install ½” exterior-grade plywood sheathing and weather-resistive barrier (Tyvek or approved equal). • We’re applicable exterior finish where repaired: vinyl siding 2. Roof Replacement • Remove existing roofing materials down to deck. • Demolish and replace any damaged roof joists • Where required to repair/replace damage joists o Install new 2” x 8” roof joists @ 16” O.C. ? Roof joists to bear in existing masonry pockets and/or approved bearing assemblies. ? Provide required lateral bracing and ties per IRC. • Replace roof decking as required with ½” plywood sheathing, fastened per code. • Install new 2-ply torch-down modified bitumen roofing system. 3. Gutters • Install 5” aluminum K-style gutters with 3” x 4” downspouts discharging to on-grade splash blocks. 4. Windows • Remove and replace ten (10) vinyl windows, same size and same location. • Installation to comply with current IRC egress and flashing requirements. 5. Exterior Doors • Install two (2) new pre-hung insulated exterior doors, installed per manufacturer specifications and code. Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance. Separate permit will be required for electrical, mechanical, and plumbing work. As per plans and as per code. | $15,000 | Mar 24, 2026 |
Violations
3| Kind | Category | Status | Fine | Balance | Date |
|---|---|---|---|---|---|
| vacant_building_notice | Vacant | open | — | — | Mar 26, 2026 |
| citation | 13 4-5A.2 | P | $500 | $0 | Dec 8, 2025 |
| citation | BC 123.8.1 | P | $1,000 | $0 | Mar 20, 2025 |
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 10, 2026 · 61 m · 1902 N FULTON AVE
- violation: SW-HGWJul 6, 2026 · 28 m · 1913 N FULTON AVE
- violation: HCD-Illegal DumpingJul 6, 2026 · 122 m · 1813 N FULTON AVE
- violation: SW-Dirty AlleyJul 3, 2026 · 57 m · 1800 W NORTH AVE
- violation: SW-HGWJul 2, 2026 · 128 m · 1904 MCKEAN AVE
- violation: HCD-Sanitation PropertyJul 2, 2026 · 141 m · 1644 W NORTH AVE
- violation: HCD-Sanitation PropertyJul 2, 2026 · 146 m · 1642 W NORTH AVE
- violation: SW-Dirty AlleyJul 1, 2026 · 57 m · 1900 N FULTON AVE
- permit: BRCMJul 1, 2026 · 143 m · 2029 N FULTON AVE
- violation: SW-Dirty AlleyJun 30, 2026 · 65 m · 1804 W NORTH AVE