Baltimore City · 21215
3801 W COLD SPRING LN
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $342,100
- Land use
- Residential (R)
- Year built
- 1920
- Last sale
- Dec 29, 2021
Assessment
| Owner | ROBINSON, JACQUETTA LYNEE' |
|---|---|
| Land use | Residential (R) |
| Total assessment | $342,100 (cycle 2026) |
| Last sale | Dec 29, 2021 — $365,000 |
| Year built | 1920 |
| Zoning | R-3 |
| Vacant | — |
Permits
5| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2024 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INSTALL INTELLIJACK TO STABILIZE THE FOUNDATION, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED SPECIFICATIONS | $2,600 | Apr 10, 2024 |
| USE2021 | USE AS A SINGLE-FAMILY DWELLING. | — | Oct 4, 2021 |
| COM2021 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-52530:REMOVE ROOF AND 2ND FLOOR LOFT FRAMING. REMOVE 1ST FLOOR REAR BUMP OUT AND LEFT SIDE BUMP OUT. CONSTRUCT A 31'X 2.5' CANTILEVER ON FIRST FLOOR LEFT SIDE. CONSTRUCT NEW SECOND FLOOR AND ROOF. CONSTRUCT NEW 12'X 26'9'' DECK AND STAIRS (STAIRCASE PARAMETERS: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) ON REAR OF HOUSE. ALL NEW INTERIOR FRAMING 2X4 STUDS 16'' O.C. , EXTERIOR FRAMING 2X6 STUDS 16'' O.C. R-20 INSULATION. SECOND FLOOR CEILING 2X8 JOISTS 16'' O.C. , R-49 INSULATION. STAIRS 2X12 STRINGERS 7.5 '' RISE 10'' TREAD 36'' WIDE. ALL WORK AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN CEILING HEIGHT OF 7' MINIMUM, 2. ALL HALLWAYS/STAIRCASES WILL MAINTAIN 36''MINIMUM WIDTH, 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND FOOTER WORK WILL BE WITHIN PRIVATE PROPERTY LINES, 5. NO OPENINGS ON ADDITION WITHIN 5' OF PROPERTY LINES) ) Original Permit Description:(COM2021-52530) REMOVE ROOF AND 2ND FLOOR LOFT FRAMING. REMOVE 1ST FLOOR REAR BUMP OUT AND LEFT SIDE BUMP OUT. CONSTRUCT A 31'X 2.5' CANTILEVER ON FIRST FLOOR LEFT SIDE. CONSTRUCT NEW SECOND FLOOR AND ROOF. CONSTRUCT NEW 12'X 26'9'' DECK AND STAIRS (STAIRCASE PARAMETERS: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) ON REAR OF HOUSE. ALL NEW INTERIOR FRAMING 2X4 STUDS 16'' O.C. , EXTERIOR FRAMING 2X6 STUDS 16'' O.C. R-20 INSULATION. SECOND FLOOR CEILING 2X8 JOISTS 16'' O.C. , R-49 INSULATION. STAIRS 2X12 STRINGERS 7.5 '' RISE 10'' TREAD 36'' WIDE. ALL WORK AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN CEILING HEIGHT OF 7' MINIMUM, 2. ALL HALLWAYS/STAIRCASES WILL MAINTAIN 36''MINIMUM WIDTH, 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND FOOTER WORK WILL BE WITHIN PRIVATE PROPERTY LINES, 5. NO OPENINGS ON ADDITION WITHIN 5' OF PROPERTY LINES) | — | Sep 29, 2021 |
| COM2021 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (20) # BRANCH CIRCUITS/FEEDERS , (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 45000 BTU FUEL-BURNING EQUIP, (2) 90000 BTU FUEL-BURNING EQUIP, (1) # GAS TEST, (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE. | $100 | Apr 5, 2021 |
| COM2021 | REMOVE ROOF AND 2ND FLOOR LOFT FRAMING. REMOVE 1ST FLOOR REAR BUMP OUT AND LEFT SIDE BUMP OUT. CONSTRUCT A 31'X 2.5' CANTILEVER ON FIRST FLOOR LEFT SIDE. CONSTRUCT NEW SECOND FLOOR AND ROOF. CONSTRUCT NEW 12'X 26'9'' DECK AND STAIRS (STAIRCASE PARAMETERS: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) ON REAR OF HOUSE. ALL NEW INTERIOR FRAMING 2X4 STUDS 16'' O.C. , EXTERIOR FRAMING 2X6 STUDS 16'' O.C. R-20 INSULATION. SECOND FLOOR CEILING 2X8 JOISTS 16'' O.C. , R-49 INSULATION. STAIRS 2X12 STRINGERS 7.5 '' RISE 10'' TREAD 36'' WIDE. ALL WORK AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN CEILING HEIGHT OF 7' MINIMUM, 2. ALL HALLWAYS/STAIRCASES WILL MAINTAIN 36''MINIMUM WIDTH, 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 4. ALL DECK AND FOOTER WORK WILL BE WITHIN PRIVATE PROPERTY LINES, 5. NO OPENINGS ON ADDITION WITHIN 5' OF PROPERTY LINES) | $35,000 | Feb 10, 2021 |
Violations
0No violations on record.
Inspections
2| Type | Status |
|---|---|
| CourtOrder | OPEN |
| CourtOrder | OPEN |
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 1, 2026 · 107 m · 3801 OAKFORD AVE
- violation: HCD-Sanitation PropertyJun 29, 2026 · 94 m · 3810 W COLD SPRING LN
- violation: HCD-Sanitation PropertyJun 24, 2026 · 147 m
- violation: PM 306.6Jun 22, 2026 · 136 m · 4000 AYRDALE AVE
- violation: PM 305.1Jun 22, 2026 · 136 m · 4000 AYRDALE AVE
- violation: HCD-Sanitation PropertyJun 17, 2026 · 136 m · 4000 AYRDALE AVE
- violation: HCD-Sanitation PropertyJun 12, 2026 · 46 m · 3800 BOARMAN AVE
- violation: HCD-Maintenance StructureJun 3, 2026 · 65 m
- violation: PM 305.5.2Jun 3, 2026 · 77 m · 3719 W COLD SPRING LN
- violation: PM 305.2.2Jun 3, 2026 · 77 m · 3719 W COLD SPRING LN
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.