Baltimore City · 21215

3826 ROLAND VIEW AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$163,333
Land use
Residential (R)
Year built
1945
Last sale
Aug 15, 2016

Assessment

OwnerSCAFF, LONDON
Land useResidential (R)
Total assessment$163,333 (cycle 2026)
Last saleAug 15, 2016 — $130,000
Year built1945
ZoningR-6
Vacant

Permits

1
TypeDescriptionCostIssued
COM2023*****LOAN/GRANT.*** FURNACE - FORCED AIR & A/C REPLACEMENT- GAS. LOCATION: BASEMENT. USE AIR CONDITIONING CONTRACTORS OF AMERICA (ACCA), CURRENT ADDITION MANUAL J HEAT LOSS CALCULATION TOOL AND USE ACCA'S MANUAL S FOR EQUIPMENT SELECTION. NOTE: PROVIDE BOTH MANUAL J & S REPORT WITH CONTRACTOR'S PROPOSAL. LOCATE UNIT IN A DRY LOCATION AND WITHIN CONDITIONED SPACE THAT PROVIDES SERVICE ACCESS ACCORDING TO MANUFACTURER’S SPECIFICATION AND APPLICABLE BALTIMORE CITY CODES. REMOVE EXISTING FURNACE AND DISPOSE OF IN LEGAL LANDFILL. FURNACE: INSTALL A 80+ GAS FIRED FORCED AIR FURNACE WITH A MINIMUM AFUE RATING OF 80% ON 2'' PATIO BLOCK TO EXISTING DUCT WORK AND GAS LINE. NEW FURNACE SHALL HAVE A MINIMUM LIMITED WARRANTY OF: 20 YEARS ON HEAT EXCHANGER; 5 YEARS ON PARTS. INCLUDE AUTO SETBACK THERMOSTAT CONTROLS, FLUE PIPE AND NEW SHUTOFF VALVES. SEAL ALL EXPOSED DUCT JOINTS AS A PART OF THIS ITEM WITH DUCT MASTIC AT ALL NEW CONNECTIONS. REMOVE EXISTING A/C UNIT AND DISPOSE OF IT IN LEGAL LANDFILL ACCORDING TO EPA STANDARDS. SUBMIT MANUFACTURER’S CUT SHEET AND COOLING LOAD CALCULATION WITH CONTRACTOR’S PROPOSAL. INSTALL CENTRAL A/C SYSTEM WITH A MINIMUM SEER OF 15.0 INCLUDING CONDENSING UNIT, A TYPE COIL, CONTROL, AND POWER WIRING, INSULATED FREON LINES, PLENUMS, EXTERIOR UNIT SETTING PAD AND CONNECTIONS TO CREATE A PRODUCT CAPABLE OF 68 F INTERIOR WHEN EXTERIOR IS 100 F AT 80% HUMIDITY. PROVIDE THE OWNER WITH MANUFACTURER’S WARRANTY, MANUAL AND 1 YEAR CONTRACTOR’S WARRANTY. ------- INTERIOR ALTERATIONS ----- - INSTALL NEW 1/2'' SHEETROCK TO STUD WALL – 32 SQ. FT. LOCATION: REAR WALL IN BASEMENT WHERE ELECTRICAL PANEL IS LOCATED. INSTALL 1/2'' GYPSUM BOARD TO FRAMING MEMBERS WITH SCREWS OR SCREW SHANK NAILS SPACED ON MORE THAN 7'' APART. GYPSUM BOARD TO HAVE A 3 COAT FINISH. STAGGER JOINTS. NOTE: WHEN ROOF HAS BEEN COMPLETED TO REMOVE DAMAGE SATURATED WALL AND REPLACE WALL WITH NEW DRYWALL. PRIME AND PAINT WALL TO MATCH AS CLOSE AS POSSIBLE. ---- EXTERIOR ALTERATIONS ------ EPDM - FULLY ADHEARED--WHITE ROOF (COOL ROOF), REPLACE MANSARD REMOVE .AS PER CODE. $25,000Sep 18, 2023

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.