Baltimore City · 21217

1002 N FULTON AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$6,000
Land use
Residential (R)
Year built
1920
Last sale
Jul 8, 2024

Assessment

Owner1002 N FULTON LLC
Land useResidential (R)
Total assessment$6,000 (cycle 2026)
Last saleJul 8, 2024
Year built1920
ZoningR-8
VacantYes

Permits

4
TypeDescriptionCostIssued
COM2024 Extend Original Permit.(original permit:COM2024-62683:SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4" CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4" 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16" ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9"MIN, RISE: 8 1/4"MAX, AND WIDTH: 36"MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16" O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12" O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4" TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF ROOF AND BACK STAIRS (TREAD: 9"MIN, RISE: 8 1/4"MAX AND WIDTH: 36"MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36", 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)) Original Permit Description:(COM2024-62683) SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4" CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4" 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16" ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9"MIN, RISE: 8 1/4"MAX, AND WIDTH: 36"MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16" O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12" O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4" TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF ROOF AND BACK STAIRS (TREAD: 9"MIN, RISE: 8 1/4"MAX AND WIDTH: 36"MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36", 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)Nov 21, 2024
COM2024SCOPE OF WORK:----INTERIOR/STRUCTURAL ALTERATIONS-----TO INCLUDE: NEW BASEMENT SLAB 4'' CONCRETE (18' X 34') WITH WELDED WIRE SUSPENDED IN POUR OVER 6 MIL. VAPOR BARRIER OVER 4'' 357 STONE. DRAIN TILE. FRAMING (FURRING) AT PARTY WALLS 2X4 FLAT @16'' ON CENTER, FRAMING USING 2X4 TO CREATE NEW PARTITION WALLS, INSTALL NEW DRYWALL, INSTALL NEW BASEBOARD TRIM, INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX, AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE. FLOOR FRAMING TO BE NEW 2X12 @16'' O.C AND 2-5/16 X11-7/8 TJI FLOOR JOIST SYSTEM @ 12'' O.C GROUTED INTO BRICK PARTY WALLS. NEW 3/4'' TONGUE AND GROOVE SUB FLOOR SCREWED AND GLUED. INSULATION IN ATTIC TO BE R-49 FIBERGLASS BATT INSULATION. R-19 INSULATION FOR EXTERIOR WALLS. INSTALL NEW DOORS AND WINDOWS (AT EXISTING OPENINGS), NEW FLOORING, KITCHEN CABINETS AND APPLIANCES. (3) DOORS TO EXTERIOR, (11) NEW INTERIOR DOORS, (14) NEW WINDOWS. ----EXTERIOR ALTERATIONS-----TO INCLUDE: RECONSTRUCTION OF ROOF AND BACK STAIRS (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), NEW GUTTERS AND DOWNSPOUTS. *NO CURBING OR UNDERPINNING. ALL WORK WILL BE DONE AS PER PLANS AND AS PER BALTIMORE CITY CODE. SEPARATE PERMIT WILL BE PULLED FOR MEP. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT. 4. ALL DECK, STAIRCASE AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)$100,000May 13, 2024
BMZ2023use for two dwelling units.Jan 27, 2023
COM2019roof stabilization as per code$54,000Mar 19, 2019

Violations

3
KindCategoryStatusDate
service_requestSW-HGWClosedJun 1, 2026
service_requestHCD-Sanitation PropertyClosedMay 27, 2026
vacant_building_noticeVacantopenAug 10, 2025

Inspections

4
TypeStatus
InitialOPEN
InitialECBOPEN
InitialECBOPEN
InitialECBOPEN

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.