Assessment
| Owner | BALTIMORE EXCEL 03, LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $13,000 (cycle 2026) |
| Last sale | Dec 7, 2021 — $27,000 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | — |
Permits
5| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2022 | USE AS A SINGLE FAMILY DWELLING, | — | Oct 21, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2021-84182:INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (33) # BRANCH CIRCUITS/FEEDERS , (55) # FIXTURES/DEVICES, (10) # LOW VOLTAGE, (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (2) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (10) # PLUMBING FIXTURES, (4) 70 CFM EXHAUST SYSTEMS AS PER CODE.) Original Permit Description:(COM2021-84182) INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (33) # BRANCH CIRCUITS/FEEDERS , (55) # FIXTURES/DEVICES, (10) # LOW VOLTAGE, (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (2) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (10) # PLUMBING FIXTURES, (4) 70 CFM EXHAUST SYSTEMS AS PER CODE. | — | May 19, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2021-82826:SCOPE OF WORK — INTERIOR ALTERATIONS, TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). PARTIAL REPLACEMENT OF EXISTING WOOD FRAMING, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR AND FROM 2ND FLOOR TO 3RD FLOOR LEVELS, AT 36''MIN WIDTH, 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF EXISTING EXTERIOR DOORS AND WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 125’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). NEW 4'' GRAY VINYL SIDING, AT EXISTING 2 STORY REAR SHED. NEW LAYER STUCCO, AT REAR WALLS, PAINTED GRAY. EXISTING FRONT MASONRY TO BE PAINTED GRAY. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)) Original Permit Description:(COM2021-82826) SCOPE OF WORK — INTERIOR ALTERATIONS, TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). PARTIAL REPLACEMENT OF EXISTING WOOD FRAMING, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR AND FROM 2ND FLOOR TO 3RD FLOOR LEVELS, AT 36''MIN WIDTH, 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF EXISTING EXTERIOR DOORS AND WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 125’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). NEW 4'' GRAY VINYL SIDING, AT EXISTING 2 STORY REAR SHED. NEW LAYER STUCCO, AT REAR WALLS, PAINTED GRAY. EXISTING FRONT MASONRY TO BE PAINTED GRAY. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | — | May 11, 2022 |
| COM2021 | SCOPE OF WORK — INTERIOR ALTERATIONS, TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). PARTIAL REPLACEMENT OF EXISTING WOOD FRAMING, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR AND FROM 2ND FLOOR TO 3RD FLOOR LEVELS, AT 36''MIN WIDTH, 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF EXISTING EXTERIOR DOORS AND WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 125’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). NEW 4'' GRAY VINYL SIDING, AT EXISTING 2 STORY REAR SHED. NEW LAYER STUCCO, AT REAR WALLS, PAINTED GRAY. EXISTING FRONT MASONRY TO BE PAINTED GRAY. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) | $75,000 | Nov 17, 2021 |
| COM2021 | INSTALL (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (33) # BRANCH CIRCUITS/FEEDERS , (55) # FIXTURES/DEVICES, (10) # LOW VOLTAGE, (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (2) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (10) # PLUMBING FIXTURES, (4) 70 CFM EXHAUST SYSTEMS AS PER CODE. | $10,000 | Nov 8, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 9, 2026 · 72 m · 1606 EDMONDSON AVE
- violation: SW-HGWJul 9, 2026 · 133 m
- violation: SW-HGWJul 9, 2026 · 133 m · 641 N FULTON AVE
- violation: HCD-Sanitation PropertyJul 7, 2026 · 128 m · 708 N MOUNT ST
- violation: SW-Dirty AlleyJul 7, 2026 · 140 m
- violation: HCD-Sanitation PropertyJun 29, 2026 · 69 m · 1608 EDMONDSON AVE
- violation: HCD-Illegal DumpingJun 29, 2026 · 149 m · 716 N GILMOR ST
- violation: HCD-Sanitation PropertyJun 25, 2026 · 131 m · 635 N FULTON AVE
- violation: SW-HGWJun 23, 2026 · 41 m · 620 N MOUNT ST
- violation: SW-HGWJun 23, 2026 · 45 m · 624 N MOUNT ST