Baltimore City · 21217
915 N GILMOR ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $6,000
- Land use
- Exempt (E)
- Year built
- 1910
- Last sale
- Jun 25, 2026
Assessment
| Owner | PROPERTY RENOVESTORS LLC |
|---|---|
| Land use | Exempt (E) |
| Total assessment | $6,000 (cycle 2026) |
| Last sale | Jun 25, 2026 — $6,000 |
| Year built | 1910 |
| Zoning | R-8 |
| Vacant | Yes |
Permits
1| Type | Description | Cost | Issued |
|---|---|---|---|
| BRCM | PROJECT DESCRIPTION Renovation of Existing Three-Story Single-Family Rowhouse with Existing 7�-0� Basement (No Underpinning Required). No change in occupancy. No underpinning proposed. Majority of existing structural framing to remain unless specifically noted below. Separate trade permits (Electrical, Mechanical, and Plumbing) will be pulled by licensed trade contractors. INTERIOR ALTERATIONS 1. Demolition � Category II interior demolition. 2. Structural Floor Framing � Remove and replace deteriorated floor joists as required. � Install new 2� x 8� wood floor joists @ 16� O.C., bearing in existing masonry joist pockets. � Provide proper end bearing per IRC requirements. � Install approved Simpson Strong-Tie connectors at joist-to-wall and joist-to-framing connections where applicable. � Install new �� OSB subfloor, screwed to new joists. 3. Basement Work (No Underpinning) � Install interior drain tile system inside basement perimeter walls. � Existing 7�-0� basement height to remain; no underpinning proposed. 4. Stairs � New code-compliant stairs proposed all floors. � Install new code-compliant handrails and guardrails as required. 5. Interior Framing � Frame new interior partition walls using 2� x 4� wood studs @ 16� O.C. � Provide required blocking for casework, vanities, shelving, and fixtures. 6. Insulation � Install R-38 batt insulation at roof/ceiling level. � Install R-21 batt insulation in new exterior framed walls. � Install R-15 batt insulation at furred masonry front wall. 7. Gypsum Board & Wall Assemblies Majority of existing drywall to remain however where required we will install as follows: � Standard interior walls and ceiling infill: �� gypsum wallboard (GWB). � Bathroom and kitchen wet walls: �� moisture-resistant GWB. � Tile and backsplash areas: �� cement board (Durock). � Install vapor barrier at insulated bearing wall assemblies where required by code. � Fire-caulk all required rated penetrations. ? EXTERIOR ALTERATIONS 1. Exterior Wall Framing (Where Applicable) � Any new exterior framed walls shall use 2� x 6� wood studs @ 16� O.C. � Any repaired exterior walls shall Install �� exterior-grade plywood sheathing and weather-resistive barrier (Tyvek or approved equal). � We�re applicable exterior finish where repaired: vinyl siding 2. Roof Replacement � Remove existing roofing materials down to deck. � Demolish and replace any damaged roof joists � Where required to repair/replace damage joists o Install new 2� x 8� roof joists @ 16� O.C. ? Roof joists to bear in existing masonry pockets and/or approved bearing assemblies. ? Provide required lateral bracing and ties per IRC. � Replace roof decking as required with �� plywood sheathing, fastened per code. � Install new 2-ply torch-down modified bitumen roofing system. 3. Gutters � Install 5� aluminum K-style gutters with 3� x 4� downspouts discharging to on-grade splash blocks. 4. Windows � Remove and replace twelve (12) vinyl windows, same size and same location. � Installation to comply with current IRC egress and flashing requirements. 5. Exterior Doors � Install Three (3) new pre-hung insulated exterior doors, installed per manufacturer specifications and code. | $25,000 | Jun 30, 2026 |
Violations
1| Kind | Category | Status | Date |
|---|---|---|---|
| vacant_building_notice | Vacant | open | Jun 20, 2008 |
Inspections
1| Type | Status | Action | Date |
|---|---|---|---|
| Extension | OPEN | FAIL INSPECTION | Apr 29, 2026 |
Nearby recent activity
- violation: SW-HGWJul 9, 2026 · 68 m
- violation: SW-HGWJul 9, 2026 · 98 m · 1000 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 100 m · 1002 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 103 m · 1004 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 106 m · 1006 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 109 m · 1008 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 112 m · 1010 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 116 m · 1012 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 123 m · 1001 N STRICKER ST
- violation: SW-HGWJul 9, 2026 · 124 m · 1016 N STRICKER ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.