Baltimore City · 21216

1600 N HILTON ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$4,393,900
Land use
Apartments (M)
Year built
2023
Last sale
Jul 30, 2021

Assessment

OwnerPARKWAY OVERLOOK APARTMENTS 4 LLC
Land useApartments (M)
Total assessment$4,393,900 (cycle 2026)
Last saleJul 30, 2021
Year built2023
ZoningR-6
Vacant

Permits

32
TypeDescriptionCostIssued
USE2023USE 1610-1612 N. HILTON STREET AS A NEW MULTI-FAMILY DWELLING CONSISTING OF 18 DWELLING UNITS AND COMMON AREA SPACES. NEW CONSTRUCTION BUILDING, PART OF THE PARKWAY OVERLOOK 9 APARTMENTS COMMUNITY. Mar 10, 2023
COM2023REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-02315:INSTALL 306 NEW SPRINKLER HEADS FOR NEW 13R APARTMENT BUILDING AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-02315) INSTALL 306 NEW SPRINKLER HEADS FOR NEW 13R APARTMENT BUILDING AS PER PLANS AS PER CODE.Mar 1, 2023
COM2023AA CONV: Full Description Loaded as CommentFeb 13, 2023
COM2022INSTALL A 15.3 KW ROOF MOUNT 34 SOLAR SYSTEM ON THE EAST FACING ROOF OF THE APARTMENT BUILDING. THE PROJECT WILL USE 450 WATT PANELS AND 1 INVERTER AS PER PLANS AS PER CODE.$22,125Feb 10, 2023
COM2022INSTALL (34) # PHOTOVOLTAIC SYSTEM, (1) # PHOTOVOLTAIC SYSTEM, (1) # PHOTOVOLTAIC SYSTEM AS PER CODE.$22,125Jan 11, 2023
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 30, 2022
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 27, 2022
USE2022[1636 N HILTON ST] CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF THREE (3) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 21, 2022
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 21, 2022
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 21, 2022
USE2022[1630 N HILTON ST] CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF ELEVEN (11) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 21, 2022
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 12, 2022
COM2022INSTALL 200A TEMPORARY METER FOR CONSTRUCTION FROM BGE POLE (POLE ADDRESS: 1618 N HILTON ST, BALTIMORE, MD 21216) $1,000Dec 6, 2022
USE2022[1624 N HILTON ST] CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF TEN (10) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 1, 2022
USE2022[1622 N HILTON ST] CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 1, 2022
USE2022[1620 N HILTON ST] USE AS A MULTI-FAMILY DWELLING CONSISTING OF THREE (3) DWELLING UNITS. BUILDING PREVIOUSLY CONTAINED FIVE (5) UNITS - TWO UNITS ARE BEING COMBINED WITH EXISTING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Dec 1, 2022
COM2022FIRE ALARM SYSTEM AS PER PLAN AS PER CODE$6,000Sep 8, 2022
COM2022FIRE ALARM SYSTEM AS PER PLAN AS PER CODE$6,000Sep 8, 2022
COM2022 Extend Original Permit.(original permit:COM2021-03948:AMEND COM2020-01668 PLAN #2020-1299 ISSUED 5/28/21 NEW 18 DU BUILDING REVISED UNDERGROUND DUCTBANKS FROM UTILITY TRANSFORMER TO HOUSE SERVICE, METER STACK, AND FIRE PUMP. REVISED ELECTRICAL ROOM LAYOUT, REVISED FIRE PUMP ROOM LAYOUT, ADDED EMERGENCY WALL PACK, REVISED ENTIRE ELECTRICAL DISTRIBUTION SYSTEM, ALL LOAD CENTER AND HOUSE PANEL SCHEDULES INCLUDING BREAKER SIZES, TYPES, AND WIRING, REVISED SIZE OF MAKEUP LOUVER FOR DRYER CHASE, ADDED DUCT SIZES TO OUTDOOR AIR DUCTS IN DRYER CHASE, ADDED DUCT SIZE FOR OUTDOOR AIR DUCT TO SS-AHU-3. REVISED LOCATION OF DSS-AHU-2. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS, ADDED SIZE FOR OUTDOOR AIR LOUVER AND DUCT FOR SS-AHU-4, REVISED TRANSFER AIR GRILLES AND DUCTS THROUGH MANAGER’S OFFICE, REVISED RETURN AIRFLOW BALANCING, REVISED DWELLING UNIT SPLIT SYSTEM SEQUENCE TO INCLUDE SEQUENCE FOR AIRCYCLER G2, REVISED DWELLING UNIT BATHROOM EXHAUST FAN SEQUENCE TO INCLUDE INFORMATION FOR FANCONNECT SWITCH CONTROL FOR AIRCYCLER G2, REVISED NOTE FOR TERMINATION OF AIR HANDLING UNIT CONDENSATE DRAIN, ADDED DETAIL FOR PLENUM RETURN DWELLING UNIT AIR HANDLING UNITS, REVISED DEVICE SIZE AND TYPE FOR DEVICE A. ADDED TRANSFER DEVICE TYPE I. REVISED NOTES 3 AND 6 TO “NOT USED.” DELETED DWELLING UNIT AIR DEVICE SCHEDULE, REVISED NOTE 2 ON SPLIT SYSTEM HEAT PUMP SCHEDULE FOR AIRCYCLER G2, REVISED DWELLING UNIT VENTILATION SCHEDULE TO REFLECT G2 AIRCYCLER, ADDED SUBSLAB PIPING FOR WATER HEATER PAN DRAINS AND AIR HANDLER CONDENSATE RECEPTORS, ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES, REVISED LOCATION OF DSS-AHU-2. ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES. ADDED P-7D AND ASSOCIATED VENT PIPING TO ALL UNIT P AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-03948) AMEND COM2020-01668 PLAN #2020-1299 ISSUED 5/28/21 NEW 18 DU BUILDING REVISED UNDERGROUND DUCTBANKS FROM UTILITY TRANSFORMER TO HOUSE SERVICE, METER STACK, AND FIRE PUMP. REVISED ELECTRICAL ROOM LAYOUT, REVISED FIRE PUMP ROOM LAYOUT, ADDED EMERGENCY WALL PACK, REVISED ENTIRE ELECTRICAL DISTRIBUTION SYSTEM, ALL LOAD CENTER AND HOUSE PANEL SCHEDULES INCLUDING BREAKER SIZES, TYPES, AND WIRING, REVISED SIZE OF MAKEUP LOUVER FOR DRYER CHASE, ADDED DUCT SIZES TO OUTDOOR AIR DUCTS IN DRYER CHASE, ADDED DUCT SIZE FOR OUTDOOR AIR DUCT TO SS-AHU-3. REVISED LOCATION OF DSS-AHU-2. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS, ADDED SIZE FOR OUTDOOR AIR LOUVER AND DUCT FOR SS-AHU-4, REVISED TRANSFER AIR GRILLES AND DUCTS THROUGH MANAGER’S OFFICE, REVISED RETURN AIRFLOW BALANCING, REVISED DWELLING UNIT SPLIT SYSTEM SEQUENCE TO INCLUDE SEQUENCE FOR AIRCYCLER G2, REVISED DWELLING UNIT BATHROOM EXHAUST FAN SEQUENCE TO INCLUDE INFORMATION FOR FANCONNECT SWITCH CONTROL FOR AIRCYCLER G2, REVISED NOTE FOR TERMINATION OF AIR HANDLING UNIT CONDENSATE DRAIN, ADDED DETAIL FOR PLENUM RETURN DWELLING UNIT AIR HANDLING UNITS, REVISED DEVICE SIZE AND TYPE FOR DEVICE A. ADDED TRANSFER DEVICE TYPE I. REVISED NOTES 3 AND 6 TO “NOT USED.” DELETED DWELLING UNIT AIR DEVICE SCHEDULE, REVISED NOTE 2 ON SPLIT SYSTEM HEAT PUMP SCHEDULE FOR AIRCYCLER G2, REVISED DWELLING UNIT VENTILATION SCHEDULE TO REFLECT G2 AIRCYCLER, ADDED SUBSLAB PIPING FOR WATER HEATER PAN DRAINS AND AIR HANDLER CONDENSATE RECEPTORS, ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES, REVISED LOCATION OF DSS-AHU-2. ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES. ADDED P-7D AND ASSOCIATED VENT PIPING TO ALL UNIT P AS PER PLANS AS PER CODE.Aug 8, 2022
USE2022CONTINUE TO USE AS A MULTI-FAMILY DWELLING CONSISTING OF TEN (10) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Jul 22, 2022
USE2022CONTINUE TO USE PORTION K/A 1600 N HILTON ST AS MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Jul 22, 2022
USE2022CONTINUE TO USE PORTION K/A 1602 N HILTON ST AS MULTI-FAMILY DWELLING CONSISTING OF SIX (6) DWELLING UNITS. PART OF THE PARKWAY OVERLOOK APARTMENTS RENOVATION PROJECT, FORMERLY KNOWN AS GWYNN CREST APARTMENTS.Jul 22, 2022
USE2022CONTINUED USE OF BUILDINGS 1600, 1602, 1604, 1606 N. HILTON STREET AS MULTI-FAMILY DWELLINGS CONSISTING OF TWENTY-FIVE (25) TOTAL UNITS. Jul 22, 2022
DEM2022DEMOLITION OF BUILDING/STRUCTURE(MASONRY)(5) LENGTH:258 WIDTH:42 HEIGHT:40 NOTE: 5 APARTMENT BUILDINGS CONNECTED ARE TO BE TORN DOWN. $0May 20, 2022
COM2021AMEND COM2020-01668 PLAN #2020-1299 ISSUED 5/28/21 NEW 18 DU BUILDING REVISED UNDERGROUND DUCTBANKS FROM UTILITY TRANSFORMER TO HOUSE SERVICE, METER STACK, AND FIRE PUMP. REVISED ELECTRICAL ROOM LAYOUT, REVISED FIRE PUMP ROOM LAYOUT, ADDED EMERGENCY WALL PACK, REVISED ENTIRE ELECTRICAL DISTRIBUTION SYSTEM, ALL LOAD CENTER AND HOUSE PANEL SCHEDULES INCLUDING BREAKER SIZES, TYPES, AND WIRING, REVISED SIZE OF MAKEUP LOUVER FOR DRYER CHASE, ADDED DUCT SIZES TO OUTDOOR AIR DUCTS IN DRYER CHASE, ADDED DUCT SIZE FOR OUTDOOR AIR DUCT TO SS-AHU-3. REVISED LOCATION OF DSS-AHU-2. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS. REVISED NOTE 11 TO REQUIREMENTS FOR AIRCYCLER G2, ADDED NOTE 18 FOR G2 FANCONNECT SWITCH AND ADDED SWITCH LOCATIONS TO UNIT PLANS, ADDED SIZE FOR OUTDOOR AIR LOUVER AND DUCT FOR SS-AHU-4, REVISED TRANSFER AIR GRILLES AND DUCTS THROUGH MANAGER’S OFFICE, REVISED RETURN AIRFLOW BALANCING, REVISED DWELLING UNIT SPLIT SYSTEM SEQUENCE TO INCLUDE SEQUENCE FOR AIRCYCLER G2, REVISED DWELLING UNIT BATHROOM EXHAUST FAN SEQUENCE TO INCLUDE INFORMATION FOR FANCONNECT SWITCH CONTROL FOR AIRCYCLER G2, REVISED NOTE FOR TERMINATION OF AIR HANDLING UNIT CONDENSATE DRAIN, ADDED DETAIL FOR PLENUM RETURN DWELLING UNIT AIR HANDLING UNITS, REVISED DEVICE SIZE AND TYPE FOR DEVICE A. ADDED TRANSFER DEVICE TYPE I. REVISED NOTES 3 AND 6 TO “NOT USED.” DELETED DWELLING UNIT AIR DEVICE SCHEDULE, REVISED NOTE 2 ON SPLIT SYSTEM HEAT PUMP SCHEDULE FOR AIRCYCLER G2, REVISED DWELLING UNIT VENTILATION SCHEDULE TO REFLECT G2 AIRCYCLER, ADDED SUBSLAB PIPING FOR WATER HEATER PAN DRAINS AND AIR HANDLER CONDENSATE RECEPTORS, ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES, REVISED LOCATION OF DSS-AHU-2. ADDED GENERAL NOTE CLARIFYING CONDENSATE DRAIN PIPE SIZES. ADDED P-7D AND ASSOCIATED VENT PIPING TO ALL UNIT P AS PER PLANS AS PER CODE.$1Feb 1, 2022
COM2021INSTALL 306 NEW SPRINKLER HEADS FOR NEW 13R APARTMENT BUILDING AS PER PLANS AS PER CODE.$93,495Nov 10, 2021
COM2021AMEND PERMIT: ADD PLUMBER AND GAS CONTRACTOR .(ORIGINAL PERMIT:COM2020-01668:CONSTRUCT NEW APARTMENT BUILDING, WITH 18 UNITS AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS. ) Original Permit Description:(COM2020-01668) CONSTRUCT NEW APARTMENT BUILDING, WITH 18 UNITS AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS. Oct 1, 2021
COM2020parking lot improvements to accommodate accessibility, installation of playground, sidewalk, handicap ramp, esc, swm, utility connections, dumpster enclosure and landscape improvements. 77,787 sf lod / 6,659.2 cy cut/ fill as per plans as per code.$1,163,000Jun 1, 2021
COM2020CONSTRUCT NEW APARTMENT BUILDING, WITH 18 UNITS AS PER PLANS AS PER CODE. SEPARATE PERMITS ARE REQUIRED FOR SPRINKLER, FIRE ALARM, AND DETECTION SYSTEMS. $3,100,000May 28, 2021
COM2019install (1) 30 btu fuel-burning equip as per code.$2,500Dec 31, 2019
COM2019install (1) 30 btu fuel-burning equip as per code.$2,500Dec 2, 2019
COM2019replace (1) 32000 btu fuel-burning equip (water heater) as per code.$1,000Apr 9, 2019

Violations

8
KindCategoryStatusFineBalanceDate
service_requestHCD-Sanitation PropertyClosedJun 3, 2026
citationPM 306.6O$100$50Jan 12, 2026
citationPM 306.1P$100$0May 27, 2025
citationPM 306.1O$100$300Mar 27, 2025
citationPM 306.6O$100$300Mar 27, 2025
citationPM 306.1P$100$0Nov 26, 2024
citationPM 306.6P$100$0Nov 26, 2024
citationPM 306.1O$100$300Sep 30, 2024

Inspections

8
TypeStatus
InitialOPEN
InitialOPEN
InitialOPEN
InitialOPEN
InitialOPEN
InitialECBOPEN
InitialOPEN
InitialOPEN

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;