Baltimore City · 21223
1058 W FAYETTE ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $363,500
- Land use
- Residential (R)
- Year built
- 1920
- Last sale
- May 6, 2022
Assessment
| Owner | SESAY, ADRIENNE |
|---|---|
| Land use | Residential (R) |
| Total assessment | $363,500 (cycle 2026) |
| Last sale | May 6, 2022 — $379,900 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | — |
Permits
8| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2022 | SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: FENCING REPLACEMENT, REPLACING APPROXIMATELY 109' OF 6' TALL WOOD FENCE WITH 109' OF 6' TALL WOOD FENCE IN BACK YARD AS PER CODE IN SAME LOCATION (*NOTES: 1. ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) | $3,500 | Apr 25, 2022 |
| USE2021 | USE AS A SINGLE-FAMILY DWELLING. | — | Dec 2, 2021 |
| COM2021 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2020-86934:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY II): INSTALL NEW FRAMING OF PERIMETER WALLS WITH 2X6 @ 16 OF PER CODE. INSTALL NEW PARTITION WALLS 2X4 @ 16OC PER PLANS. INSULATE WALLS AND CEILINGS PER CODE. INSTALL NEW DRYWALL TO ALL NEW FRAMING, INSTALL NEW BASEMENT STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE LOCATION, INSTALL RISER BOX STAIRCASE WITHIN EXISTING OPENING (AT FIRST FLOOR), INSTALL NEW HANDRAIL (MINIMUM HEIGHT: 36''), REPOINT OF BASEMENT WALL, INSTALL 21 NEW REPLACEMENT WINDOWS INT THE EXISTING OPENINGS. INSTALL 3 EXTERIOR DOORS IN THE EXISTING OPENINGS. INSTALL 20 NEW PREYING INTERIOR DOORS. PROPERTY TO HAVE 4 BEDROOMS AND 2.5 BATHS, INSTALLATION OF NEW FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, INSTALLATION OF NEW 330SQ/FT CONCRETE PAD AND 4'' THICK 460SQ/FT CONCRETE PATIO, INSTALL NEW GUTTERS, INSTALL NEW DOWNSPOUT, INSTALL NEW FLASHING, INSTALL NEW ROOF SHINGLES, PROVIDE VENTING AT ROOF, REPAIR, SCRAPE AND PAINT CORNICE (ALL HABITABLE AREAS WILL BE MAINTAIN 7' CEILING HEIGHT AND ALL HALLWAYS WILL MAINTAIN 3' WIDTH), AS PER PLANS/AS PER CODE, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK.) Original Permit Description:(COM2020-86934) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY II): INSTALL NEW FRAMING OF PERIMETER WALLS WITH 2X6 @ 16 OF PER CODE. INSTALL NEW PARTITION WALLS 2X4 @ 16OC PER PLANS. INSULATE WALLS AND CEILINGS PER CODE. INSTALL NEW DRYWALL TO ALL NEW FRAMING, INSTALL NEW BASEMENT STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE LOCATION, INSTALL RISER BOX STAIRCASE WITHIN EXISTING OPENING (AT FIRST FLOOR), INSTALL NEW HANDRAIL (MINIMUM HEIGHT: 36''), REPOINT OF BASEMENT WALL, INSTALL 21 NEW REPLACEMENT WINDOWS INT THE EXISTING OPENINGS. INSTALL 3 EXTERIOR DOORS IN THE EXISTING OPENINGS. INSTALL 20 NEW PREYING INTERIOR DOORS. PROPERTY TO HAVE 4 BEDROOMS AND 2.5 BATHS, INSTALLATION OF NEW FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, INSTALLATION OF NEW 330SQ/FT CONCRETE PAD AND 4'' THICK 460SQ/FT CONCRETE PATIO, INSTALL NEW GUTTERS, INSTALL NEW DOWNSPOUT, INSTALL NEW FLASHING, INSTALL NEW ROOF SHINGLES, PROVIDE VENTING AT ROOF, REPAIR, SCRAPE AND PAINT CORNICE (ALL HABITABLE AREAS WILL BE MAINTAIN 7' CEILING HEIGHT AND ALL HALLWAYS WILL MAINTAIN 3' WIDTH), AS PER PLANS/AS PER CODE, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. | — | Nov 29, 2021 |
| COM2021 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-60874:INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS , (10) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2021-60874) INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS , (10) # LOW VOLTAGE AS PER CODE. | — | Nov 23, 2021 |
| COM2021 | INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 72000 BTU FUEL-BURNING EQUIP, (1) # GAS TEST, (2) 72000 BTU FUEL-BURNING EQUIP, (2) 50000 BTU FUEL-BURNING EQUIP, (1) # WATER SERVICE PIPE ( 1-2 FAM. RES.), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (1-2 FAM. RES.) AS PER CODE. | $6,500 | May 28, 2021 |
| COM2021 | INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (25) # BRANCH CIRCUITS/FEEDERS , (10) # LOW VOLTAGE AS PER CODE. | $6,500 | Apr 15, 2021 |
| COM2020 | SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY II): INSTALL NEW FRAMING OF PERIMETER WALLS WITH 2X6 @ 16 OF PER CODE. INSTALL NEW PARTITION WALLS 2X4 @ 16OC PER PLANS. INSULATE WALLS AND CEILINGS PER CODE. INSTALL NEW DRYWALL TO ALL NEW FRAMING, INSTALL NEW BASEMENT STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL INFILL AT THE STAIRCASE LOCATION, INSTALL RISER BOX STAIRCASE WITHIN EXISTING OPENING (AT FIRST FLOOR), INSTALL NEW HANDRAIL (MINIMUM HEIGHT: 36''), REPOINT OF BASEMENT WALL, INSTALL 21 NEW REPLACEMENT WINDOWS INT THE EXISTING OPENINGS. INSTALL 3 EXTERIOR DOORS IN THE EXISTING OPENINGS. INSTALL 20 NEW PREYING INTERIOR DOORS. PROPERTY TO HAVE 4 BEDROOMS AND 2.5 BATHS, INSTALLATION OF NEW FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, INSTALLATION OF NEW 330SQ/FT CONCRETE PAD AND 4'' THICK 460SQ/FT CONCRETE PATIO, INSTALL NEW GUTTERS, INSTALL NEW DOWNSPOUT, INSTALL NEW FLASHING, INSTALL NEW ROOF SHINGLES, PROVIDE VENTING AT ROOF, REPAIR, SCRAPE AND PAINT CORNICE (ALL HABITABLE AREAS WILL BE MAINTAIN 7' CEILING HEIGHT AND ALL HALLWAYS WILL MAINTAIN 3' WIDTH), AS PER PLANS/AS PER CODE, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. | $60,000 | Feb 17, 2021 |
| COM2020 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY I): REMOVE ALL KITCHEN CABINETS, CARPETS, APPLIANCES, PLUMBING FIXTURES AND REMOVAL OF ALL ASSOCIATED DEBRIS. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY BUILDING CODE. DEMO ONLY, SEPARATE PERMIT WILL BE PULLED FOR INTERIOR RENOVATIONS. | $500 | Nov 20, 2020 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 2, 2026 · 66 m · 119 N CARLTON ST
- violation: SW-HGWJul 1, 2026 · 46 m
- violation: SW-HGWJun 26, 2026 · 49 m · 1100 W FAYETTE ST
- violation: SW-HGWJun 26, 2026 · 53 m
- violation: SW-HGWJun 26, 2026 · 54 m · 104 N CARLTON ST
- violation: SW-HGWJun 26, 2026 · 55 m · 106 N CARLTON ST
- violation: SW-HGWJun 26, 2026 · 55 m · 1102 W FAYETTE ST
- violation: SW-HGWJun 26, 2026 · 58 m · 1077 W FAYETTE ST
- violation: SW-HGWJun 26, 2026 · 59 m · 1104 W FAYETTE ST
- violation: SW-HGWJun 26, 2026 · 62 m · 1079 W FAYETTE ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.