Baltimore City · 21223

2568 W FAYETTE ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$12,000
Land use
Residential (R)
Year built
1915
Last sale
Mar 29, 2021

This owner holds 75 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerBALTIMORE EXCEL 02 LLC
Land useResidential (R)
Total assessment$12,000 (cycle 2026)
Last saleMar 29, 2021 — $14,000
Year built1915
ZoningR-8
Vacant

Permits

5
TypeDescriptionCostIssued
USE2020USE AS A SINGLE FAMILY DWELLING, Jul 26, 2021
COM2021 Extend Original Permit.(original permit:COM2021-51771:INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (45) # FIXTURES/DEVICES, (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 70 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (8) # PLUMBING FIXTURES, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-51771) INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (45) # FIXTURES/DEVICES, (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 70 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (8) # PLUMBING FIXTURES, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.Jul 20, 2021
COM2021 Extend Original Permit.(original permit:COM2020-88220:SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). REPAIR/REPLACEMENT OF EXISTING WOOD FLOOR FRAMING AT STAIR OPENINGS, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED, THE EXISTING JOIST FRAMING ARE TO REMAIN AS SHOWN. THE REMAINING STRUCTURE WILL BE SECURED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF 2 EXTERIOR DOORS AND 8 EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION).NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’ IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN A CEILING HEIGHT OF 7', 2. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 3. ALL HALLWAYS WILL MAINTAIN A WIDTH OF 36'', 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)) Original Permit Description:(COM2020-88220) SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). REPAIR/REPLACEMENT OF EXISTING WOOD FLOOR FRAMING AT STAIR OPENINGS, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED, THE EXISTING JOIST FRAMING ARE TO REMAIN AS SHOWN. THE REMAINING STRUCTURE WILL BE SECURED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF 2 EXTERIOR DOORS AND 8 EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION).NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’ IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN A CEILING HEIGHT OF 7', 2. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 3. ALL HALLWAYS WILL MAINTAIN A WIDTH OF 36'', 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)Jul 20, 2021
COM2021INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (45) # FIXTURES/DEVICES, (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 70 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (8) # PLUMBING FIXTURES, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.$7,500Jan 19, 2021
COM2020SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMO CATEGORY II: THE REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT). REPAIR/REPLACEMENT OF EXISTING WOOD FLOOR FRAMING AT STAIR OPENINGS, AS PER PLANS. LESS THAN 1/3 OF THE EXISTING STRUCTURE SHALL BE IMPACTED, THE EXISTING JOIST FRAMING ARE TO REMAIN AS SHOWN. THE REMAINING STRUCTURE WILL BE SECURED. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH. NEW INTERIOR NONSTRUCTURAL PARTITION WALLS, AS PER PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. EXTERIOR ALTERATIONS TO INCLUDE: REPLACEMENT OF 2 EXTERIOR DOORS AND 8 EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION).NEW WOOD FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’ IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE (4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS). ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS, *SEPARATE PERMIT WILL BE PULLED FOR ANY MEP WORK. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN A CEILING HEIGHT OF 7', 2. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT FOR ONE OCCUPANT OR 50 SQ/FT PER OCCUPANT, 3. ALL HALLWAYS WILL MAINTAIN A WIDTH OF 36'', 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)$45,000Dec 24, 2020

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.