Assessment
| Owner | BALTIMORE EXCEL 05 LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $150,000 (cycle 2026) |
| Last sale | Apr 23, 2025 |
| Year built | 1900 |
| Zoning | R-8 |
| Vacant | — |
Permits
5| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2023 | USE AS A SINGLE-FAMILY DWELLING. | — | Jun 4, 2024 |
| COM2024 | Extend Original Permit.(original permit:COM2023-84526:SCOPE OF WORK: ----- INTERIOR ALTERATIONS ------- : INTERIOR DEMO CATEGORY II: REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT. THE REMOVAL OF LESS THAN 1/3 OF THE EXISTING STRUCTURE. THE REMAINING STRUCTURE WILL BE SECURED. EXTG CONC BASEMENT SLAB TO REMAIN, REPAIR SURFACE W/ NEW CONC OVERLAY. NO LOWERING OF SLAB. NO UNDERPINNING. REPLACEMENT OF WOOD FRAMING AS SHOWN IN FRAMING PLANS. LESS THAN 1/3 OF EXISTING FRAMING IS TO BE REPLACED, AS PER PLANS. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH, 36” MINIMUM WIDTH. NEW INTERIOR PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. ----- EXTERIOR ALTERATIONS ------ : REPLACEMENT OF EXTERIOR DOORS AND EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW 4'' GRAY VINYL SIDING OR NEW STUCCO PAINTED GRAY, AT REAR AND/OR SIDE FACADE. REPAIR ROOFING SURFACE WITH NEW MEMBRANE OVERLAY. ------ FENCING ------ NEW P.T. WOOD FENCE OR STEEL CHAINLINK FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET MAX APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). AS PER PLANS AND AS PER CODE. ***** NO WORK OUTSIDE OF PROPERTY LINE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. ***** ) Original Permit Description:(COM2023-84526) SCOPE OF WORK: ----- INTERIOR ALTERATIONS ------- : INTERIOR DEMO CATEGORY II: REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT. THE REMOVAL OF LESS THAN 1/3 OF THE EXISTING STRUCTURE. THE REMAINING STRUCTURE WILL BE SECURED. EXTG CONC BASEMENT SLAB TO REMAIN, REPAIR SURFACE W/ NEW CONC OVERLAY. NO LOWERING OF SLAB. NO UNDERPINNING. REPLACEMENT OF WOOD FRAMING AS SHOWN IN FRAMING PLANS. LESS THAN 1/3 OF EXISTING FRAMING IS TO BE REPLACED, AS PER PLANS. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH, 36” MINIMUM WIDTH. NEW INTERIOR PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. ----- EXTERIOR ALTERATIONS ------ : REPLACEMENT OF EXTERIOR DOORS AND EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW 4'' GRAY VINYL SIDING OR NEW STUCCO PAINTED GRAY, AT REAR AND/OR SIDE FACADE. REPAIR ROOFING SURFACE WITH NEW MEMBRANE OVERLAY. ------ FENCING ------ NEW P.T. WOOD FENCE OR STEEL CHAINLINK FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET MAX APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). AS PER PLANS AND AS PER CODE. ***** NO WORK OUTSIDE OF PROPERTY LINE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. ***** | — | Apr 29, 2024 |
| COM2023 | INSTALL (1) 80000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (3) 70 CFM EXHAUST SYSTEMS , (1) # ELECTRIC WATER HEATER, (9) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # STORM WATER CONNECTION (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (2) 40000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | $10,000 | Dec 18, 2023 |
| COM2023 | INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (45) # FIXTURES/DEVICES, (6) # LOW VOLTAGE AS PER CODE. | $5,000 | Dec 18, 2023 |
| COM2023 | SCOPE OF WORK: ----- INTERIOR ALTERATIONS ------- : INTERIOR DEMO CATEGORY II: REMOVAL OF EXISTING PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, FLOORING MATERIALS, AND REMOVAL OF DEBRIS AND/OR EQUIPMENT. THE REMOVAL OF LESS THAN 1/3 OF THE EXISTING STRUCTURE. THE REMAINING STRUCTURE WILL BE SECURED. EXTG CONC BASEMENT SLAB TO REMAIN, REPAIR SURFACE W/ NEW CONC OVERLAY. NO LOWERING OF SLAB. NO UNDERPINNING. REPLACEMENT OF WOOD FRAMING AS SHOWN IN FRAMING PLANS. LESS THAN 1/3 OF EXISTING FRAMING IS TO BE REPLACED, AS PER PLANS. NEW STAIRS FROM BASEMENT TO 1ST FLOOR AND FROM 1ST FLOOR TO 2ND FLOOR LEVELS, AT 8.25” MAX RISE AND 9” MIN TREAD DEPTH, 36” MINIMUM WIDTH. NEW INTERIOR PARTITION WALLS, AS PER FLOOR PLANS. INSTALLATION OF NEW DRYWALL, FRAME EXTERIOR PERIMETER WALLS, FINISHED PRIME AND PAINT. ----- EXTERIOR ALTERATIONS ------ : REPLACEMENT OF EXTERIOR DOORS AND EXTERIOR WINDOWS (DOORS AND WINDOWS IN THE SAME SIZE AND LOCATION). NEW 4'' GRAY VINYL SIDING OR NEW STUCCO PAINTED GRAY, AT REAR AND/OR SIDE FACADE. REPAIR ROOFING SURFACE WITH NEW MEMBRANE OVERLAY. ------ FENCING ------ NEW P.T. WOOD FENCE OR STEEL CHAINLINK FENCE ALONG REAR YARD PROPERTY LINE, AT 6'-0'' MAX HEIGHT, APPROXIMATELY 75’-0” IN TOTAL LENGTH, ALONG INSIDE EDGE OF PROPERTY LINE, 4X4 POSTS, 8 FEET MAX APART ON MINIMUM OF 12'' DEEP FOOTERS (ALL FENCING AND FOOTER WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES). AS PER PLANS AND AS PER CODE. ***** NO WORK OUTSIDE OF PROPERTY LINE. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. ***** | $55,000 | Oct 27, 2023 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 9, 2026 · 78 m
- permit: BRCMJul 9, 2026 · 96 m · 2133 HOLLINS ST
- violation: SW-HGWJul 8, 2026 · 70 m · 2011 BOOTH ST
- violation: HCD-Sanitation PropertyJul 8, 2026 · 102 m · 8 S PAYSON ST
- permit: BRCMJul 4, 2026 · 75 m · 2101 W BALTIMORE ST
- violation: PM 305.2.2Jul 1, 2026 · 92 m · 8 S PAYSON ST
- violation: PM 305.2.2Jul 1, 2026 · 96 m · 4 S PAYSON ST
- violation: SW-HGWJul 1, 2026 · 131 m
- violation: PM 305.2.2Jun 30, 2026 · 90 m · 2009 HOLLINS ST
- violation: SW-HGWJun 30, 2026 · 96 m · 2000 HOLLINS ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;