Baltimore City · 21223
2000 W BALTIMORE ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $1,144,500
- Land use
- Exempt Commercial (EC)
- Year built
- 1980
- Last sale
- Aug 27, 2018
Assessment
| Owner | BON SECOURS HOSPITAL |
|---|---|
| Land use | Exempt Commercial (EC) |
| Total assessment | $1,144,500 (cycle 2026) |
| Last sale | Aug 27, 2018 |
| Year built | 1980 |
| Zoning | H |
| Vacant | — |
Permits
29| Type | Description | Cost | Issued |
|---|---|---|---|
| BCCM | Install 1 illuminated wall sign as per plan as per code | $2,000 | Jun 26, 2025 |
| COM2022 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2021-02790:INSTALLATION OF TWO GAS FIRED HOT WATER BOILERS AND A NEW WATER HEATER TO SUPPORT AN EXISTING OFFICE BUILDING ALONG WITH NEW UNIT HEATERS IN THE SERVICE BUILDING AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-02790) INSTALLATION OF TWO GAS FIRED HOT WATER BOILERS AND A NEW WATER HEATER TO SUPPORT AN EXISTING OFFICE BUILDING ALONG WITH NEW UNIT HEATERS IN THE SERVICE BUILDING AS PER PLANS AS PER CODE. | — | Feb 4, 2022 |
| COM2021 | RE-ROUTE BULK PIPE TO FEED RISER AND RELOCATED FDC, PROVIDE FIRE PROTECTION (33 HEADS) ON NEWLY UTILITY TUNNEL PER NFPA 13 AND LOCAL REGULATION AS PER PLANS AS PER CODE. | $45,000 | Jan 19, 2022 |
| COM2021 | AMEND PERMIT: ADD PLUMBER AND HVAC CONTRACTOR . (ORIGINAL PERMIT:COM2021-02087:RENOVATE TO CREATE NEW IN-BUILDING UTILITY PATH AND ADD A NEW SHAFT ON THE NORTH SIDE OF THE 1992 BUILDING TO EXTEND UTILITIES TO UPPER FLOORS AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-02087) RENOVATE TO CREATE NEW IN-BUILDING UTILITY PATH AND ADD A NEW SHAFT ON THE NORTH SIDE OF THE 1992 BUILDING TO EXTEND UTILITIES TO UPPER FLOORS AS PER PLANS AS PER CODE. | — | Nov 2, 2021 |
| COM2021 | AMEND PERMIT: ADD GAS AND HVAC CONTRACTOR . (ORIGINAL PERMIT:COM2021-02790:INSTALLATION OF TWO GAS FIRED HOT WATER BOILERS AND A NEW WATER HEATER TO SUPPORT AN EXISTING OFFICE BUILDING ALONG WITH NEW UNIT HEATERS IN THE SERVICE BUILDING AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-02790) INSTALLATION OF TWO GAS FIRED HOT WATER BOILERS AND A NEW WATER HEATER TO SUPPORT AN EXISTING OFFICE BUILDING ALONG WITH NEW UNIT HEATERS IN THE SERVICE BUILDING AS PER PLANS AS PER CODE. | — | Oct 27, 2021 |
| COM2021 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2021-02087:RENOVATE TO CREATE NEW IN-BUILDING UTILITY PATH AND ADD A NEW SHAFT ON THE NORTH SIDE OF THE 1992 BUILDING TO EXTEND UTILITIES TO UPPER FLOORS AS PER PLANS AS PER CODE.) Original Permit Description:(COM2021-02087) RENOVATE TO CREATE NEW IN-BUILDING UTILITY PATH AND ADD A NEW SHAFT ON THE NORTH SIDE OF THE 1992 BUILDING TO EXTEND UTILITIES TO UPPER FLOORS AS PER PLANS AS PER CODE. | — | Oct 26, 2021 |
| COM2021 | INSTALLATION OF TWO GAS FIRED HOT WATER BOILERS AND A NEW WATER HEATER TO SUPPORT AN EXISTING OFFICE BUILDING ALONG WITH NEW UNIT HEATERS IN THE SERVICE BUILDING AS PER PLANS AS PER CODE. | $400,000 | Oct 26, 2021 |
| COM2021 | RENOVATE TO CREATE NEW IN-BUILDING UTILITY PATH AND ADD A NEW SHAFT ON THE NORTH SIDE OF THE 1992 BUILDING TO EXTEND UTILITIES TO UPPER FLOORS AS PER PLANS AS PER CODE. | $2,000,000 | Oct 25, 2021 |
| USE2021 | USE AND OCCUPANCY FOR LEVEL 2, 4 AND 5 OF THE 1992 BON SECOURS BUILDING. LEVEL 2 OCCUPANCY IS LAB SPACE, PHYSICAL THERAPY SUITE, OFFICE SPACE AND DIALYSIS SUITE LEVEL 4 OCCUPANCY IS OFFICE SPACE LEVEL 5 OCCUPANCY IS PHARMACY SUITE, STORAGE SPACE | — | Jul 14, 2021 |
| COM2021 | MODIFICATION TO THE EXISTING WET SPRINKLER SYSTEM, REMOVAL OF EXISTING SPRIHNKLERS WITHIN AREA OF WORK AND INSTALL NEW SPRINKLER HEADS ON THE 2ND, 4TH AND 5TH FLOORS, INSTALL NEW SPRINKLER PIPE AND HEADS PER HYDRAULIC CALCS PERFORMED ON 5TH & 3RD FLOORS, TOTAL OF 164 RECESSED PENDENT SPRINKLER HEADS AND 12 UPRIGHT SPRINKLER HEADS WILL BE INSTALLED AS PER PLANS AS PER CODE. | $132,800 | Jun 17, 2021 |
| COM2021 | INSTALL (142) # LOW VOLTAGE AS PER CODE. | $15,250 | Jun 11, 2021 |
| COM2021 | UPGRADE FIRE ALARM SYSTEM AS PER PLANS AS PER CODE. | $2,500,000 | Jun 10, 2021 |
| COM2021 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR .(ORIGINAL PERMIT:COM2020-02419:AMEND PERMIT COM2020-00992 PLAN NO 2020-727 ISSUED 7-2-2020 ADDITIONAL RENOVATION SCOPE WITHIN THE SAME BUILDING AS PER PLANS AS PER CODE. ) Original Permit Description:(COM2020-02419) AMEND PERMIT COM2020-00992 PLAN NO 2020-727 ISSUED 7-2-2020 ADDITIONAL RENOVATION SCOPE WITHIN THE SAME BUILDING AS PER PLANS AS PER CODE. | — | Apr 1, 2021 |
| COM2021 | AMEND PERMIT: ADD HVAC AND PLUMBER CONTRACTOR .(ORIGINAL PERMIT:COM2020-02419:AMEND PERMIT COM2020-00992 PLAN NO 2020-727 ISSUED 7-2-2020 ADDITIONAL RENOVATION SCOPE WITHIN THE SAME BUILDING AS PER PLANS AS PER CODE. ) Original Permit Description:(COM2020-02419) AMEND PERMIT COM2020-00992 PLAN NO 2020-727 ISSUED 7-2-2020 ADDITIONAL RENOVATION SCOPE WITHIN THE SAME BUILDING AS PER PLANS AS PER CODE. | — | Mar 30, 2021 |
| COM2020 | AMEND PERMIT COM2020-01814 PLAN 2020-1425 ISSUED 7-31-20: ADDED SPRINKLERS TO THE 3RD FLOOR, A TOTAL OF 158 NEW HEADS AS PER PLANS AS PER CODE. | $0 | Mar 16, 2021 |
| COM2020 | AMEND PERMIT COM2020-00992 PLAN NO 2020-727 ISSUED 7-2-2020 ADDITIONAL RENOVATION SCOPE WITHIN THE SAME BUILDING AS PER PLANS AS PER CODE. | $2,500,000 | Feb 24, 2021 |
| COM2020 | FIRE ALARM UPGRADE ON THE 1ST AND 3RD FLOORS AS PER PLANS AS PER CODE.. | $20,000,000 | Dec 15, 2020 |
| COM2020 | AMEND PERMIT: ADD PLUMBER CONTRACTOR . (ORIGINAL PERMIT:COM2020-00992:INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM.) Original Permit Description:(COM2020-00992) INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM. | — | Dec 8, 2020 |
| COM2020 | INSTALL (429) DATA CABLES (LOW VOLTAGE) AS PER CODE. | $66,400 | Oct 23, 2020 |
| COM2020 | AMEND PERMIT: CHANGE HVAC, PLUMBER, GAS CONTRACTOR .(ORIGINAL PERMIT:COM2020-00992:INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM.) Original Permit Description:(COM2020-00992) INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM. | — | Oct 21, 2020 |
| USE2020 | USE AND OCCUPANCY FOR LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING. LEVEL 1 OCCUPANCY WILL BE FOR EMERGENCY DEPARTMENT. LEVEL 3 WILL BE OPERATING SUITE AND CLINIC SPACE. | — | Sep 15, 2020 |
| COM2020 | INSTALL (29) # LOW VOLTAGE AS PER CODE. | $19,997 | Aug 13, 2020 |
| COM2020 | REMOVAL OF THE EXISTING UPRIGHT SPRINKLER HEADS AND INSTALLING NE PENDENT SPRINKLER HEADS TO PROVIDE COVERAGE OF THE NEW ROOM AND CEILING LAYOUTS FOR THE PHASE 2 PORTION OF THIS PROJECT ON FLOOR 1 AND FLOOR 3, WITHIN THE AREA OF WORK 250 RECESSED PENDENT SPRINKLER HEADS, 10 UPRIGHT SPRINKLER HEADS, AND 42 PLUGS WILL BE INSTALL AS PER PLANS AS PER CODE. | $132,800 | Jul 31, 2020 |
| COM2020 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR .(ORIGINAL PERMIT:COM2020-00992:INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM.) Original Permit Description:(COM2020-00992) INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM. | — | Jul 14, 2020 |
| COM2020 | INTERIOR RENOVATIONS OF LEVELS 1 AND 3 OF THE 1992 BON SECOURS BUILDING, LEVEL 1 WILL BE AN EMERGENCY DEPARTMENT AND LEVEL 3 WILL BE CLINICS AS PER PLANS AS PER CODE.SEPARATE PERMIT REQUIRED FOR FIRE ALARM SYSTEM & SPRINKLER SYSTEM. | $20,000,000 | Jul 2, 2020 |
| COM2020 | CATEGORY 1 - INTERIOR NO STRUCTURAL DEMOLITION OF 1ST AND 3RD FLOOR AS PER PLANS AND AS PER CODE. SEPARATE PERMIT WILL BE REQUIRED FOR FUTURE INTERIOR FIT-OUT. | $350,000 | Mar 5, 2020 |
| COM2020 | SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: SIGN INSTALLATION, INSTALL 1 ILLUMINATED WALL SIGN - GRACE MEDICAL CENTER A LIFEBRIDGE HEALTH CENTER - 44'' X 172'' = 52.55 SQ FT, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. | $2,000 | Jan 17, 2020 |
| COM2019 | scope of work: exterior alterations to include: sign installation, install 1 non-ill wall sign - bon secours lifebridge- 40" x 175" = 48.61 sq ft install 1 non-ill wall sign - parking - 24" x 141" = 23.5 sq ft install 1 non-ill wall sign - 2000 w. baltimore st - 13" x 173" = 15.62 sq ft install 1 non-ill wall panel sign - bon secours - 10" x 116" = 8.06 sq ft install 1 non-ill wall panel sign - main entrance - 8" x 116" = 6.44 sq ft install 1 banner - care bravely - 20' x 15' = 300 sq ft install 1 illuminated wall sign - emergency - 43" x 142" = 42.40 sq ft install 1 non-ill wall panel sign - bon secours lifebridge - 4.75' x 10' = 47.5 sq ft, all work will be done according to baltimore city code and per submiitted drawings. | $7,500 | Nov 8, 2019 |
| COM2019 | scope of work: exterior alterations to include: sign installation, install 2 mesh banners - care bravely best medical care-30' x 18' = 540 sq ft and install 1 mesh banner - bon secours lifebridge-10' x 35' = 350 sq ft, all work will be done according to baltimore city code and per submitted plans. (*banners should be anchored to the building) | $4,000 | Nov 8, 2019 |
Violations
1| Kind | Category | Status | Date |
|---|---|---|---|
| service_request | HCD-Sanitation Property | Closed | May 26, 2026 |
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 8, 2026 · 88 m · 8 S PAYSON ST
- violation: SW-HGWJul 8, 2026 · 99 m · 2011 BOOTH ST
- violation: SW-Dirty AlleyJul 7, 2026 · 136 m · 1943 W FAYETTE ST
- permit: BRCMJul 4, 2026 · 109 m · 2101 W BALTIMORE ST
- violation: PM 305.2.2Jul 1, 2026 · 78 m · 4 S PAYSON ST
- violation: PM 305.2.2Jul 1, 2026 · 86 m · 8 S PAYSON ST
- violation: PM 306.1Jul 1, 2026 · 140 m · 2010 W FAYETTE ST
- violation: PM 305.2.2Jul 1, 2026 · 140 m · 2010 W FAYETTE ST
- violation: SW-HGWJun 30, 2026 · 129 m · 2000 HOLLINS ST
- violation: HCD-Sanitation PropertyJun 29, 2026 · 76 m · 2 S PAYSON ST
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-11; sdat-properties: 2026-07-12;