Baltimore City · 21230
229 E MONTGOMERY ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $570,500
- Land use
- Residential (R)
- Year built
- 1875
- Last sale
- Dec 18, 2017
Assessment
| Owner | ZOLTOSKI, MICHAEL J |
|---|---|
| Land use | Residential (R) |
| Total assessment | $570,500 (cycle 2026) |
| Last sale | Dec 18, 2017 — $525,000 |
| Year built | 1875 |
| Zoning | R-7 |
| Vacant | — |
Permits
12| Type | Description | Cost | Issued |
|---|---|---|---|
| BRCM | remove kitchen cabinets, kitchen floor and drywall on kitchen wall and ceiling. Install new kitchen hardwood floor, kitchen cabinets, and drywall in kitchen wall and ceiling. paint kitchen walls, ceiling and trim. Install backsplash on kitchen wall. Install new French drain system in the basement. install new 2" rat slab of concrete under kitchen floor with drain tile system. Approved For Work only. Subject to the permitted uses and regulations under the provisions of the Zoning Ordinance. | $30,000 | Jun 29, 2026 |
| COM2024 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-77081:INSTALL (4) # PLUMBING FIXTURES AS PER CODE.) Original Permit Description:(COM2023-77081) INSTALL (4) # PLUMBING FIXTURES AS PER CODE. | — | Apr 9, 2024 |
| COM2024 | AA CONV: Full Description Loaded as Comment | — | Mar 21, 2024 |
| COM2023 | INSTALL (1) 200 AMPS EXISTING ELECTRICAL METERS AS PER CODE.************ AS PER CHAP ATP: AS PER CHAP AUTHORIZATION TO PROCEED. • ON THE SIDE ELEVATION, REPLACE AT THE 1ST FLOOR ONE (1) EXISTING BGE ENTRANCE CABLE IN ITS ENTIRETY WITH ONE (1) NEW BGE ENTRANCE CABLE AS REQUIRED FOR PROPER WATERPROOFING. NEW LINESETS TO BE COVERED IN ALUMINUM COVERINGS AS REQUIRED FOR PROPER WATERPROOFING. NEW LINESETS TO BE SAME SIZE, COLOR, LOCATION, AND ARCHITECTURAL STYLE AS HISTORIC LINESETS. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES. | $1,000 | Dec 20, 2023 |
| COM2023 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.****************AS PER CHAP AUTHORIZATION TO PROCEED. • ON THE SIDE ELEVATION, REPLACE AT THE 1ST FLOOR ONE (1) EXISTING A/C CONDENSER UNIT IN ITS ENTIRETY WITH ONE (1) NEW 30000 BTU A/C CONDENSER UNIT AS REQUIRED FOR PROPER WATERPROOFING. NEW CONDENSER LINESETS TO BE COVERED IN ALUMINUM COVERINGS AS REQUIRED FOR PROPER WATERPROOFING. NEW CONDENSER UNIT TO BE SAME SIZE, COLOR, LOCATION, AND STYLE AS EXISTING HISTORIC CONDENSER UNIT. NEW LINESETS TO BE SAME SIZE, COLOR, LOCATION, AND ARCHITECTURAL STYLE AS HISTORIC LINESETS. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES. | $6,000 | Oct 19, 2023 |
| COM2023 | INSTALL (4) # BRANCH CIRCUITS/FEEDERS , (50) # FIXTURES/DEVICES, (8) # FIXTURES/DEVICES, (1) # BRANCH CIRCUITS/FEEDERS AS PER CODE. | $9,000 | Aug 23, 2023 |
| COM2023 | INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0 AS PER CODE. | $2,500 | Aug 22, 2023 |
| COM2023 | INSTALL (4) # PLUMBING FIXTURES AS PER CODE. | $2,500 | Aug 21, 2023 |
| COM2023 | CATEGORY 3 DEMO (500 SF) OF BEARING AND NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 2ND FLOOR REAR WALL. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (500 SF) W/ STUD WALLS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (4). NEW EXTERIOR WORK: NEW 2ND FLOOR REAR ADDITION (9'-8''X18')(174 SF), NEW 2ND FLOOR SIDE ADDITION (11'-6''X3')(34.5 SF). NEW 2ND FLOOR SIDE LANDING & STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS TO NEW ROOFTOP DECK (25'-6.5''X18'). NEW EXTERIOR DOORS (1), WINDOWS (7). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES)*******************************AS PER CHAP AUTHORIZATION TO PROCEED. • ON THE REAR AND SIDE ELEVATIONS, PROVIDE AT THE 1ST AND 2ND FLOORS ONE (1) NEW ADDITION AS REQUIRED FOR PROPER WATERPROOFING AND STRUCTURAL INTEGRITY. NEW ADDITION TO BE CLAD IN NEW HARDIE BOARD TEXTURED ARCHITECTURAL PANELS WITH SAND-GROOVED FINISH. AT THE 1ST AND 2ND FLOORS, THE NEW ADDITION IS TO HAVE FOUR (4) 1/1 DOUBLE HUNG ALUMINUM CLAD WINDOWS APPLIED WITH BALTIMORE BULLNOSE TRIM. AT THE 2ND FLOOR, THE NEW ADDITION BUMP-OUT IS TO HAVE ONE (1) 4W3H CASEMENT AND AWNING ALUMINUM CLAD WINDOW ASSEMBLY AND TWO (2) 1W3H CASEMENT AND AWNING WINDOW ASSEMBLY SYSTEMS AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW WINDOWS TO BE FIT THE NEW MASONRY OPENINGS WITH NO FILLER. NEW WINDOWS TO HAVE EBONY CLAD EXTERIOR SASH FINISH. THE NEW ADDITION BUMP-OUT IS TO BE CLAD IN A PRE-FABRICATED STANDING SEAM METAL PANEL SYSTEM. NEW PRE-FABRICATED STEEL TO BE EBONY. • ON THE SIDE ELEVATION, PROVIDE AT THE 2ND FLOOR ONE (1) NEW 6-PANEL OR ½-LITE WOOD DOOR AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW DOOR TO FIT THE NEW MASONRY OPENING WITH NO FILLER. NEW DOOR TO BE SAME SIZE AND STYLE AS HISTORIC WOOD DOORS. NEW DOOR TO BE PAINTED TRICORN BLACK. APPLICANT TO RETURN TO CHAP STAFF TO VERIFY THE DOOR STYLE. • ON THE SIDE AND REAR ELEVATIONS, PROVIDE AT THE BUILDING’S ROOFLINE ONE (1) NEW HALF-ROUND WHITE METAL GUTTERS WITH ROUND DOWNSPOUTS AS REQUIRED FOR PROPER WATERPROOFING. • AT THE BUILDING’S RIDGELINE, PROVIDE NEW TORCH DOWN ROLLED RUBBER ROOFING MEMBRANE AS REQUIRE FOR PROPER WATERPROOFING. NEW ROOF TO BE SAME SIZE, COLOR AND PITCH AS HISTORIC FLAT ROODS. • AT THE BUILDING’S ROOFLINE, PROVIDE ONE (1) NEW PRESSURE-TREATED WOOD DECK ABOVE PROPOSED REAR ADDITION TO BE CONSTRUCTED AS PER PLANS AS REQUIRED FOR STRUCTURAL INTEGRITY AND PROPER WATERPROOFING. NEW DECKING STRUCTURE TO HAVE BLACK METAL RAILS WITH CABLE PICKETS. NEW DECKING STRUCTURE TO BE ACCESSED VIA NEW PRESSURE-TREATED WOOD STAIRCASE. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES. | $50,000 | Aug 1, 2023 |
| BMZ2022 | construct a an addition at 2nd floor rear (9'-8" x 18') and a balcony. | — | Feb 23, 2022 |
| COM2021 | PER CHAPS ATP: PENETRATE ROOF WITH CYLINDRICAL CONCENTRIC VENT PIPE. ATTACH A LOW-PROFILE HIGH WIND TERMINATION CAP. SEAL ROOF PENETRATION WITH MANUFACTURER’S APPROVED FLASHING. SEAL WITH TAR AND PAINT SILVER TO MATCH ROOF. VENT PIPE AND CAP WILL NOT EXCEED AN OVERALL HEIGHT OF 24”. VENT PIPE AND CAP WILL NOT EXCEED AN OVERALL HEIGHT ABOVE THE ROOF PEAK OF 18”. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES.INSTALL (1) 30000 BTU FUEL-BURNING EQUIP, (1) 30000 BTU FUEL-BURNING EQUIP AS PER CODE. | $8,400 | May 28, 2021 |
| COM2020 | PER CHAP: ATP: FEDERAL HILL HISTORIC DISTRICT - REPLACE 16 TO 20 WINDOWS WITH MARVIN ULTIMATE G2 EBONY ALUMINUM CLAD ONE-OVER-ONE WINDOWS WITH RIDGELAND CASING; REPLACE FRONT DOOR WITH SIMPSON SOLID WOOD FOUR-PANEL DOOR; REPLACE SIDE DOOR WITH FIBERGLASS DOOR (SPECS TO BE PROVIDED TO CHAP). ALL WINDOWS AND DOORS TO FIT ORIGINAL OPENINGS. ALL WORK TO BE COMPLETED AS PER INFORMATION/PLANS/SPECS IN CHAP FILES. | $39,000 | Dec 8, 2020 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: 13 5-4Jul 7, 2026 · 81 m · 208 WARREN AVE
- violation: 13 4-5Jul 7, 2026 · 81 m · 208 WARREN AVE
- violation: HCD-Sanitation PropertyJun 23, 2026 · 138 m
- violation: HCD-Sanitation PropertyJun 19, 2026 · 143 m · 836 WILLIAM ST
- violation: PM 305.2.2Jun 17, 2026 · 150 m · 836 WILLIAM ST
- violation: HCD-Sanitation PropertyJun 14, 2026 · 143 m · 836 WILLIAM ST
- violation: HCD-Illegal DumpingJun 9, 2026 · 143 m · 128 E CHURCHILL ST
- violation: HCD-Sanitation PropertyJun 3, 2026 · 71 m
- violation: HCD-Sanitation PropertyJun 1, 2026 · 62 m · 208 E CHURCHILL ST
- violation: HCD-Sanitation PropertyMay 31, 2026 · 96 m
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.