Assessment
| Owner | ODF PATAPSCO LLC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $260,700 (cycle 2026) |
| Last sale | Oct 26, 2022 — $220,000 |
| Year built | 1875 |
| Zoning | R-8 |
| Vacant | — |
Permits
14| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2024 | INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | $10,000 | Nov 15, 2024 |
| COM2024 | Extend Original Permit.(original permit:COM2024-51032:CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4"RISER,11"TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (16). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12' X 6'-3") (75 SQFT X 2) (150 SF),NEW 3RD FLOOR REAR ADDITION (12' X 35') (420 SQFT),NEW 1ST FLOOR REAR DECK (12' X 6') W/ STEPS TO EXISTING GRADE, NEW 2ND FLOOR REAR DECK (12' X 6') NEW 3RD FLOOR REAR DECK (12' X 6') W/ 5' Ø SPIRAL STAIRCASE, NEW ROOFTOP DECK (12' X 12'), NEW EXTERIOR DOORS (4), WINDOWS (6). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36", 3. ALL BEDROOMS WILL MAINTAIN 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY. AS PER PLANS AND AS PER CODE.) Original Permit Description:(COM2024-51032) CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4"RISER,11"TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (16). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12' X 6'-3") (75 SQFT X 2) (150 SF),NEW 3RD FLOOR REAR ADDITION (12' X 35') (420 SQFT),NEW 1ST FLOOR REAR DECK (12' X 6') W/ STEPS TO EXISTING GRADE, NEW 2ND FLOOR REAR DECK (12' X 6') NEW 3RD FLOOR REAR DECK (12' X 6') W/ 5' Ø SPIRAL STAIRCASE, NEW ROOFTOP DECK (12' X 12'), NEW EXTERIOR DOORS (4), WINDOWS (6). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36", 3. ALL BEDROOMS WILL MAINTAIN 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY. AS PER PLANS AND AS PER CODE. | — | Oct 18, 2024 |
| COM2024 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-58914:INSTALL (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2023-58914) INSTALL (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Jun 25, 2024 |
| COM2024 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-59116:INSTALL (40) # BRANCH CIRCUITS/FEEDERS , (60) # FIXTURES/DEVICES, (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (6) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2023-59116) INSTALL (40) # BRANCH CIRCUITS/FEEDERS , (60) # FIXTURES/DEVICES, (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (6) # LOW VOLTAGE AS PER CODE. | — | May 30, 2024 |
| COM2024 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-65109:INSTALL (1) 60000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.) Original Permit Description:(COM2023-65109) INSTALL (1) 60000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | — | May 20, 2024 |
| COM2024 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2023-58914:INSTALL (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2023-58914) INSTALL (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | — | May 17, 2024 |
| COM2024 | CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (16). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12' X 6'-3'') (75 SQFT X 2) (150 SF),NEW 3RD FLOOR REAR ADDITION (12' X 35') (420 SQFT),NEW 1ST FLOOR REAR DECK (12' X 6') W/ STEPS TO EXISTING GRADE, NEW 2ND FLOOR REAR DECK (12' X 6') NEW 3RD FLOOR REAR DECK (12' X 6') W/ 5' Ø SPIRAL STAIRCASE, NEW ROOFTOP DECK (12' X 12'), NEW EXTERIOR DOORS (4), WINDOWS (6). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY. AS PER PLANS AND AS PER CODE. | $75,000 | Feb 6, 2024 |
| COM2023 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS | $5,000 | Jun 14, 2023 |
| COM2023 | INSTALL (1) 60000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | $1,000 | May 5, 2023 |
| COM2023 | INSTALL (40) # BRANCH CIRCUITS/FEEDERS , (60) # FIXTURES/DEVICES, (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (6) # LOW VOLTAGE AS PER CODE. | $9,000 | Mar 23, 2023 |
| COM2023 | INSTALL (17) # PLUMBING FIXTURES, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP, (1) 80000 BTU FUEL-BURNING EQUIP AS PER CODE. | $3,000 | Mar 23, 2023 |
| COM2023 | INSTALL (1) 60000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE. | $3,000 | Mar 14, 2023 |
| COM2023 | CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS PER PLANS. NEW INTERIOR WORK: FRAMING (1,000 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (16). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12' X 6'-3'') (75 SQFT X 2) (150 SF),NEW 3RD FLOOR REAR ADDITION (12' X 35') (420 SQFT),NEW 1ST FLOOR REAR DECK (12' X 6') W/ STEPS TO EXISTING GRADE, NEW 2ND FLOOR REAR DECK (12' X 6') NEW 3RD FLOOR REAR DECK (12' X 6') W/ 5' Ø SPIRAL STAIRCASE, NEW ROOFTOP DECK (12' X 12'), NEW EXTERIOR DOORS (4), WINDOWS (6). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES, 5. ALL EXTERIOR WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES) | $75,000 | Feb 21, 2023 |
| COM2022 | INSTALL (1) 100 AMPS ELECTRIC SERVICE (<=600V) AS PER CODE. | $1,000 | May 18, 2022 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 6, 2026 · 27 m · 21 E RANDALL ST
- violation: HCD-Sanitation PropertyJun 28, 2026 · 54 m · 1615 S CHARLES ST
- violation: SW-Dirty AlleyJun 18, 2026 · 110 m · 1605 OLIVE ST
- violation: HCD-Maintenance StructureJun 11, 2026 · 45 m · 33 E RANDALL ST
- permit: BUSEJun 11, 2026 · 138 m · 1542 LIGHT ST
- permit: BRCMJun 5, 2026 · 53 m · 1612 MARSHALL ST
- violation: HCD-Sanitation PropertyJun 2, 2026 · 138 m · 10 W RANDALL ST
- violation: HCD-Sanitation PropertyJun 2, 2026 · 141 m · 12 W RANDALL ST
- violation: HCD-Sanitation PropertyJun 2, 2026 · 144 m · 14 W RANDALL ST
- permit: BRCMMay 21, 2026 · 86 m · 53 E RANDALL ST