Baltimore City · 21230

305 E WEST ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$420,000
Land use
Residential (R)
Year built
1870
Last sale
Aug 6, 2019

Assessment

OwnerGILBERT, JOHN JOSEPH
Land useResidential (R)
Total assessment$420,000 (cycle 2026)
Last saleAug 6, 2019 — $231,000
Year built1870
ZoningR-8
Vacant

Permits

6
TypeDescriptionCostIssued
USE2022USE AS A SINGLE-FAMILY DWELLING.Sep 7, 2022
COM2022 Extend Original Permit.(original permit:COM2021-85678:SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY III): FRAMING USING 2X6 ON THE EXTERIOR WALL AND USING 2X4 TO CREATE NEW PARTITION WALLS WITHIN THE PROPERTY, INSTALL NEW DRYWALL, INSTALL NEW TRIM, INSTALL 14 NEW INTERIOR DOORS, 2 EXTERIOR DOORS, 6 WINDOWS AND 3 VINYL WINDOWS (DOORS AND WINDOWS WILL BE INSTALLED AT EXISTING OPENINGS), INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, INSTALLATION OF HANDRAIL (MINIMUM HEIGHT: 36''), SISTERING OF FLOOR JOISTS SYSTEM, RECONSTRUCTION OF ROOF, TILE FLOORING, LAMINATE FLOORING, CARPET, WINDOW STOOL/APRON, CASING, CABINETRY, WOOD FLOORING, SHEATHING, ROOFING, FASCIA, GUTTER/DOWNSPOUT, DECKING, SIDING, CONSTRUCTION OF NEW EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) LEADING TO NEW ROOF TOP DECK, INSTALLATION OF NEW FENCING IN THE SAME LOCATION AS PREVIOUS FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)) Original Permit Description:(COM2021-85678) SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY III): FRAMING USING 2X6 ON THE EXTERIOR WALL AND USING 2X4 TO CREATE NEW PARTITION WALLS WITHIN THE PROPERTY, INSTALL NEW DRYWALL, INSTALL NEW TRIM, INSTALL 14 NEW INTERIOR DOORS, 2 EXTERIOR DOORS, 6 WINDOWS AND 3 VINYL WINDOWS (DOORS AND WINDOWS WILL BE INSTALLED AT EXISTING OPENINGS), INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, INSTALLATION OF HANDRAIL (MINIMUM HEIGHT: 36''), SISTERING OF FLOOR JOISTS SYSTEM, RECONSTRUCTION OF ROOF, TILE FLOORING, LAMINATE FLOORING, CARPET, WINDOW STOOL/APRON, CASING, CABINETRY, WOOD FLOORING, SHEATHING, ROOFING, FASCIA, GUTTER/DOWNSPOUT, DECKING, SIDING, CONSTRUCTION OF NEW EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) LEADING TO NEW ROOF TOP DECK, INSTALLATION OF NEW FENCING IN THE SAME LOCATION AS PREVIOUS FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)Jun 30, 2022
COM2022INSTALL (30) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS NEW ELECTRICAL METERS AS PER CODE.$2,000Jun 4, 2022
COM2022INSTALL (1) 1 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 50 CFM EXHAUST SYSTEMS , (1) 1 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.$10,000May 23, 2022
COM2022INSTALL (18) # PLUMBING FIXTURES, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR, (1) 65000 BTU FUEL-BURNING EQUIP, (1) 85000 BTU FUEL-BURNING EQUIP, (1) 45000 BTU FUEL-BURNING EQUIP AS PER CODE.$5,000May 5, 2022
COM2021SCOPE OF WORK: INTERIOR/EXTERIOR ALTERATIONS TO INCLUDE: INTERIOR DEMOLITION (CATEGORY III): FRAMING USING 2X6 ON THE EXTERIOR WALL AND USING 2X4 TO CREATE NEW PARTITION WALLS WITHIN THE PROPERTY, INSTALL NEW DRYWALL, INSTALL NEW TRIM, INSTALL 14 NEW INTERIOR DOORS, 2 EXTERIOR DOORS, 6 WINDOWS AND 3 VINYL WINDOWS (DOORS AND WINDOWS WILL BE INSTALLED AT EXISTING OPENINGS), INSTALL NEW INTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, INSTALLATION OF HANDRAIL (MINIMUM HEIGHT: 36''), SISTERING OF FLOOR JOISTS SYSTEM, RECONSTRUCTION OF ROOF, TILE FLOORING, LAMINATE FLOORING, CARPET, WINDOW STOOL/APRON, CASING, CABINETRY, WOOD FLOORING, SHEATHING, ROOFING, FASCIA, GUTTER/DOWNSPOUT, DECKING, SIDING, CONSTRUCTION OF NEW EXTERIOR STAIRCASE (TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN) LEADING TO NEW ROOF TOP DECK, INSTALLATION OF NEW FENCING IN THE SAME LOCATION AS PREVIOUS FENCING, 4X4 POSTS, 8 FEET APART ON MINIMUM OF 12'' DEEP FOOTERS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES)$324,583.04Jan 4, 2022

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;