Baltimore City · 21230

107 E RANDALL ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$525,200
Land use
Residential (R)
Year built
1900
Last sale
Jul 24, 2025

Assessment

OwnerHIGGINS, NICHOLAS
Land useResidential (R)
Total assessment$525,200 (cycle 2026)
Last saleJul 24, 2025 — $540,000
Year built1900
ZoningR-8
Vacant

Permits

6
TypeDescriptionCostIssued
USE2023USE PREMISES AS A SINGLE FAMILY DWELLINGOct 16, 2023
COM2023INSTALL (15) # BRANCH CIRCUITS/FEEDERS , (1) 100 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE.$500Aug 29, 2023
COM2023INSTALL (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 75000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.$9,500Aug 24, 2023
COM2023INSTALL (14) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR, (1) 65000 BTU FUEL-BURNING EQUIP, (1) 85000 BTU FUEL-BURNING EQUIP AS PER CODE.$5,000Aug 1, 2023
COM2023SCOPE OF WORK:------INTERIOR ALTERATIONS------UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLAN AND CERTIFICATION. THE ENGINEER'S CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING HEIGHT 6’ PROPOSED HEIGHT 7’6”. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND SUBMITTED PLANS.$5,000Jul 20, 2023
COM2023NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING & FLOOR MATERIAL, & REMOVAL OF DEBRIS AND EQUIP. REMOVE FLOOR JOISTS FOR NEW STAIRS’ FRAMING. NEW FOUNDATION FOR SECOND FLOOR ADDITION. NEW SECOND FLOOR ADDITION. (12’-0” X 20’-0”) NEW ROOF TOP DECK (12’-0” X 16’-0) NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR BASEMENT, 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS (12), NEW EXTERIOR DOORS(3), NEW WINDOWS(8), NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW CONCRETE PARKING PAD. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). (MECH., ELECT. AND PLUMBING PERMITS TO OBTAIN SEPARATELY.), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN MINIMUM 70SQFT FOR ONE OCCUPANT OR 50SQFT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES. 5. ALL EXTERIOR WORK WILL MAINTAIN ALL PROPER SETBACKS AND BE DONE WITHIN PRIVATE PROPERTY LINES)$95,000Jun 21, 2023

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-11; sdat-properties: 2026-07-12;