Baltimore City · 21230

1717 BYRD ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$377,400
Land use
Residential (R)
Year built
1900
Last sale
Apr 7, 2022

This owner holds 5 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerKOWITZ, DAVID MICHAEL
Land useResidential (R)
Total assessment$377,400 (cycle 2026)
Last saleApr 7, 2022
Year built1900
ZoningR-8
Vacant

Permits

7
TypeDescriptionCostIssued
USE2022USE AS A SINGLE-FAMILY DWELLING.Feb 22, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-56652:NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING & FLOOR MATERIAL, & REMOVAL OF DEBRIS AND EQUIP. REMOVE SECOND FLOOR REAR WALL. REMOVE FLOOR JOISTS FOR NEW STAIRS’ FRAMING. NEW SECOND FLOOR ADDITION (12’-6'' X 10’-0”) & SECOND FLOOR REAR DECK. (12'-6''X 8'-0'') NEW THIRD FLOOR ADDITION (12’-6'' X 37’-9”) & THIRD FLOOR REAR DECK. (12'-6''X 22'-0''). NEW ROOF TOP DECK (12’-6” X 20’-0”) NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS(19), NEW EXTERIOR DOORS(4), NEW WINDOWS(7), NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW REAR CONCRETE PATIO. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). (MECH., ELECT. AND PLUMBING PERMITS TO OBTAIN SEPARATELY. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN 7' MINIMUM CEILING HEIGHT, 2. ALL HALLWAYS WILL MAINTAIN 36''MINIMUM WIDTH, 3. ADDITION AND ROOF TOP DECK WILL MAINTAIN ALL PROPER SETBACKS AND ALL WORK WILL DONE WITHIN PRIVATE PROPERTY LINES)) Original Permit Description:(COM2021-56652) NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING & FLOOR MATERIAL, & REMOVAL OF DEBRIS AND EQUIP. REMOVE SECOND FLOOR REAR WALL. REMOVE FLOOR JOISTS FOR NEW STAIRS’ FRAMING. NEW SECOND FLOOR ADDITION (12’-6'' X 10’-0”) & SECOND FLOOR REAR DECK. (12'-6''X 8'-0'') NEW THIRD FLOOR ADDITION (12’-6'' X 37’-9”) & THIRD FLOOR REAR DECK. (12'-6''X 22'-0''). NEW ROOF TOP DECK (12’-6” X 20’-0”) NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS(19), NEW EXTERIOR DOORS(4), NEW WINDOWS(7), NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW REAR CONCRETE PATIO. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). (MECH., ELECT. AND PLUMBING PERMITS TO OBTAIN SEPARATELY. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN 7' MINIMUM CEILING HEIGHT, 2. ALL HALLWAYS WILL MAINTAIN 36''MINIMUM WIDTH, 3. ADDITION AND ROOF TOP DECK WILL MAINTAIN ALL PROPER SETBACKS AND ALL WORK WILL DONE WITHIN PRIVATE PROPERTY LINES)Feb 15, 2022
COM2021UNDERPINNING OF EXISTING BASEMENT AREA 40’-0''X 11’-8”'' BASEMENT. EXISTING HEIGHT IS 5’-2'' AND NEW HEIGHT SHALL BE 7’-7”. “UNDERPINNING OF FOUNDATION WALLS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION'' ALL WORK SHALL BE IN ACCORDANCE WITH BALTIMORE CITY BUILDING CODES AND PER SUBMITTED PLANS.$12,000Nov 17, 2021
COM2021INSTALL (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (15) # BRANCH CIRCUITS/FEEDERS , (15) # LOW VOLTAGE AS PER CODE.$500Sep 14, 2021
COM2021INSTALL (21) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE, NEW INTERIOR, (1) # SANITARY CONNECTION, NEW INTERIOR, (1) 65000 BTU FUEL-BURNING EQUIP, (1) 85000 BTU FUEL-BURNING EQUIP AS PER CODE.$5,000Aug 30, 2021
COM2021INSTALL (1) 18000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (2) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 40000 BTU FUEL-BURNING EQUIP(FURNACE), (4) 50 CFM EXHAUST SYSTEMS AS PER CODE.$14,300Aug 14, 2021
COM2021NON-STRUCTURAL DEMO & REMOVAL OF PLASTER, DRYWALL, WINDOWS, DOORS, NON-BEARING WALLS, ROOFING & FLOOR MATERIAL, & REMOVAL OF DEBRIS AND EQUIP. REMOVE SECOND FLOOR REAR WALL. REMOVE FLOOR JOISTS FOR NEW STAIRS’ FRAMING. NEW SECOND FLOOR ADDITION (12’-6'' X 10’-0”) & SECOND FLOOR REAR DECK. (12'-6''X 8'-0'') NEW THIRD FLOOR ADDITION (12’-6'' X 37’-9”) & THIRD FLOOR REAR DECK. (12'-6''X 22'-0''). NEW ROOF TOP DECK (12’-6” X 20’-0”) NEW INTERIOR FRAMING & DRYWALL (2X4STUDS AT 16''O.C.) FOR 1ST & 2ND FLOOR. NEW 3'-0'' WIDE INTERIOR STAIRS (7.75''MAX RISERS & 10'' MIN. TREADS) AND HANGERS. NEW FLOOR FINISHING, NEW INTERIOR DOORS(19), NEW EXTERIOR DOORS(4), NEW WINDOWS(7), NEW SIDINGS AND NEW RUBBER ROOF OVER EXISTING ROOF. EXISTING WINDOWS AND DOORS SAME SIZES AND LOCATIONS. NEW REAR CONCRETE PATIO. NEW INSULATION (R49 FOR ROOF, R21 FOR EXTERIOR WALLS). (MECH., ELECT. AND PLUMBING PERMITS TO OBTAIN SEPARATELY. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN 7' MINIMUM CEILING HEIGHT, 2. ALL HALLWAYS WILL MAINTAIN 36''MINIMUM WIDTH, 3. ADDITION AND ROOF TOP DECK WILL MAINTAIN ALL PROPER SETBACKS AND ALL WORK WILL DONE WITHIN PRIVATE PROPERTY LINES)$100,000May 20, 2021

Violations

1
KindCategoryStatusDate
service_requestHCD-Sanitation PropertyClosedMay 5, 2026

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.