Baltimore City · 21230

1813 LIGHT ST

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$435,000
Land use
Residential (R)
Year built
1900
Last sale
Aug 12, 2019

Assessment

Owner1813 LIGHT STREET PARTNERS, LLC
Land useResidential (R)
Total assessment$435,000 (cycle 2026)
Last saleAug 12, 2019 — $150,000
Year built1900
ZoningR-8
Vacant

Permits

9
TypeDescriptionCostIssued
USE2020USE AS A SINGLE-FAMILY DWELLING. May 29, 2020
COM2020 Extend Original Permit.(original permit:COM2019-81469:INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,860 SF) W/ STUD WALLS, BASEMENT STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW REAR WINDOW WELL (3'X5'). NEW STUCCO ON REAR. NEW EXTERIOR DOORS (2), WINDOWS (12). AS PER PLANS, AS PER CODE ) Original Permit Description:(COM2019-81469) INTERIOR WORK: CATEGORY 2 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,860 SF) W/ STUD WALLS, BASEMENT STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW REAR WINDOW WELL (3'X5'). NEW STUCCO ON REAR. NEW EXTERIOR DOORS (2), WINDOWS (12). AS PER PLANS, AS PER CODE May 13, 2020
COM2019install (1) 150 amps electric service up to 600v (#amps), (15) # low voltage, (22) # branch circuits/feeders , (64) # fixtures/devices as per code.$7,800Dec 26, 2019
COM2019install new front basement window & window well (3’x5’)(15 sf). as per plans, as per code.$2,000Dec 23, 2019
COM2019install (1) 2400 btu air-con system, heat pump, (1) # new distribution system (1-2 family) as per code.$8,500Dec 18, 2019
COM2019install (1) # water service pipe (reconstruction), (1) # sanitary connection (reconstruction0, (17) # plumbing fixtures, (1) # electric water heater as per code.$2,000Nov 27, 2019
COM2019remove formstone, clean and repoint existing brick per baltimore city code$2,900Nov 1, 2019
COM2019underpinning of foundation walls as per attached engineer's plans and certification. the engineer certification is required at completion of work and with a report of the exact dates of periodic inspections during the construction. existing basement height = 6'-0", proposed height = 8'-0". new 4" concrete slab on 4" gravel.$5,000Oct 28, 2019
COM2019interior work: category 2 demo (500 sf) of bearing & non-bearing stud walls, stairs, plaster, trim, insulation, flooring / roofing & debris. new floor & roof joists as per plans. new interior work: framing (1,860 sf) w/ stud walls, basement staircase (7-3/4"riser,11"tread,3'wide) w/ hangers, drywall, trim, insulation (r-20 walls, r-49 roof). doors (15). new exterior work: new rear window well (3'x5'). new stucco on rear. new exterior doors (2), windows (12). as per plans, as per code $80,000Oct 25, 2019

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;