Assessment
| Owner | PHILLIPS, AUSTIN |
|---|---|
| Land use | Residential (R) |
| Total assessment | $456,400 (cycle 2026) |
| Last sale | May 3, 2022 — $480,000 |
| Year built | 1919 |
| Zoning | R-8 |
| Vacant | — |
Permits
10| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2022 | USE AS A SINGLE-FAMILY DWELLING. | — | Feb 25, 2022 |
| COM2022 | Extend Original Permit.(original permit:COM2020-83765: INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR WALL. DEMO EXISITNG 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,364 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12'X9'-8'')X2 = (232 SF), NEW INTERIOR STAIRCASE TO NEW ROOFTOP DECK (12'X16'), NEW EXTERIOR DOORS (3), WINDOWS (11). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (12'X15)(180 SF). AS PER PLANS, AS PER CODE ) Original Permit Description:(COM2020-83765) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR WALL. DEMO EXISITNG 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,364 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12'X9'-8'')X2 = (232 SF), NEW INTERIOR STAIRCASE TO NEW ROOFTOP DECK (12'X16'), NEW EXTERIOR DOORS (3), WINDOWS (11). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (12'X15)(180 SF). AS PER PLANS, AS PER CODE | — | Feb 17, 2022 |
| COM2022 | REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-59185:INSTALL (14) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 35000 BTU FUEL-BURNING EQUIP, (1) 75000 BTU FUEL PIPING (OTHER THAN 1 OR 2 FAMILY) AS PER CODE.) Original Permit Description:(COM2021-59185) INSTALL (14) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 35000 BTU FUEL-BURNING EQUIP, (1) 75000 BTU FUEL PIPING (OTHER THAN 1 OR 2 FAMILY) AS PER CODE. | — | Jan 11, 2022 |
| COM2021 | Extend Original Permit.(original permit:COM2021-67489:INSTALL (1) 1 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 50 CFM EXHAUST SYSTEMS , (1) 1 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-67489) INSTALL (1) 1 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 50 CFM EXHAUST SYSTEMS , (1) 1 BTU FUEL-BURNING EQUIP AS PER CODE. | — | Dec 23, 2021 |
| COM2021 | Extend Original Permit.(original permit:COM2020-83765: INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR WALL. DEMO EXISITNG 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,364 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12'X9'-8'')X2 = (232 SF), NEW INTERIOR STAIRCASE TO NEW ROOFTOP DECK (12'X16'), NEW EXTERIOR DOORS (3), WINDOWS (11). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (12'X15)(180 SF). AS PER PLANS, AS PER CODE ) Original Permit Description:(COM2020-83765) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR WALL. DEMO EXISITNG 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,364 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12'X9'-8'')X2 = (232 SF), NEW INTERIOR STAIRCASE TO NEW ROOFTOP DECK (12'X16'), NEW EXTERIOR DOORS (3), WINDOWS (11). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (12'X15)(180 SF). AS PER PLANS, AS PER CODE | — | Aug 9, 2021 |
| COM2021 | SCOPE OF WORK: ELECTRICAL ALTERATIONS TO INCLUDE: COMPLETE REWIRE: INSTALLATION OF 75 FIXTURES/DEVICES, INSTALLATION OF 22 NEW CIRCUITS AND 200 AMP SERVICE, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE | $7,000 | Jun 20, 2021 |
| COM2021 | INSTALL (1) 1 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 50 CFM EXHAUST SYSTEMS , (1) 1 BTU FUEL-BURNING EQUIP AS PER CODE. | $10,000 | Jun 15, 2021 |
| COM2021 | INSTALL (14) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 35000 BTU FUEL-BURNING EQUIP, (1) 75000 BTU FUEL PIPING (OTHER THAN 1 OR 2 FAMILY) AS PER CODE. | $500 | Mar 26, 2021 |
| COM2020 | SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS. | $5,000 | Feb 4, 2021 |
| COM2020 | INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR WALL. DEMO EXISITNG 2ND FLOOR REAR ADDITION. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,364 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (15). NEW EXTERIOR WORK: NEW 2-STORY REAR ADDITION (12'X9'-8'')X2 = (232 SF), NEW INTERIOR STAIRCASE TO NEW ROOFTOP DECK (12'X16'), NEW EXTERIOR DOORS (3), WINDOWS (11). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (12'X15)(180 SF). AS PER PLANS, AS PER CODE | $100,000 | Nov 18, 2020 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- violation: HCD-Sanitation PropertyJul 3, 2026 · 81 m · 1611 WEBSTER ST
- permit: BRCMJul 2, 2026 · 92 m · 1631 WEBSTER ST
- permit: BCCMJun 26, 2026 · 112 m · 843 E FORT AVE
- permit: BUSEJun 25, 2026 · 36 m · 1500 BOYLE ST
- permit: BRCMJun 19, 2026 · 48 m · 1546 BOYLE ST
- permit: BCCMJun 17, 2026 · 112 m · 843 E FORT AVE
- violation: SW-HGWJun 4, 2026 · 141 m
- violation: HCD-CCE Building Permit ComplaintJun 3, 2026 · 95 m · 742 E FORT AVE
- permit: BRCMMay 28, 2026 · 86 m · 1625 WEBSTER ST
- permit: BCCMMay 21, 2026 · 112 m · 843 E FORT AVE