Assessment
| Owner | ASR BALTIMORE REFINERY, LLC |
|---|---|
| Land use | Commercial (C) |
| Total assessment | $24,593,700 (cycle 2026) |
| Last sale | Jul 22, 2022 |
| Year built | 1922 |
| Zoning | MI |
| Vacant | — |
Permits
30| Type | Description | Cost | Issued |
|---|---|---|---|
| COM2024 | INSTALLATION OF NEW FIRE ALARM EQUIPMENT IN NEW RAW SUGAR STORAGE BUILDING TO INCLUDE FIRE ALARM CONTROL PANEL, PULL STATIONS, STROBE, HORN/STROBE, TAMPER, FLOW AND SUPERVISORY DEVICES. AS PER PLANS AS PER CODE. | — | Feb 19, 2026 |
| BCCM | Install new fire alarm devices to bring existing building up to code. | $60,000 | Jan 22, 2026 |
| COM2024 | RELOCATION OF OLD FUEL OIL PUMP HOUSE TO INSIDE OF FUEL OIL STORAGE TANKS CONTAINMENT POND. TO INCLUDE NEW PUMP HOUSE STRUCTURE, PUMPS, PIPING, AND UPDATED CONTROLS AND ELECTRICAL AS PER PLANS AS PER CODE. | — | Nov 6, 2025 |
| COM2025 | AMEND PERMIT# COM#2023-03745 (PLAN 2023-3081), ISSUED ON 1/8/2025 CONVERT THE APPROVED DELUGE SYSTEM TO PRE-ACTION SPRINKLER SYSTEM (12 new heads) AS PER PLANS AS PER CODE. | — | Oct 20, 2025 |
| COM2023 | SCOPE OF WORK:-----EXTERIOR ALTERATIONS----DEMOLITION AND REPLACEMENT OF EXISTING FENDER SYSTEM. INSTALLATION OF NEW STEEL PILES AND ASSOCIATED CONCRETE PILE CAPS AS PER PLANS AS PER CODE. | — | Jul 28, 2025 |
| COM2023 | INSTALL NEW NFPA 13 SPRINKLER SYSTEM IN A NEW FACTORY FACILITY. SPRINKLER SYSTEM WILL CONSIST OF 779 HEADS WITH LARGEST PIPE SIZE EQUAL TO 6 INCH AS PER PLANS AS PER CODE. | $585,000 | Jan 8, 2025 |
| COM2024 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2023-00085:SCOPE OF WORK:---NEW CONSTRUCTION----CONSTRUCT NEW SUGAR STORAGE FACILITY AS PER PLANS AS PER CODE. (ASSOCIATED WITH PRIOR PLAN# 2022-1691 (NEW SUGAR STORAGE - DEMOLITION SCOPE ONLY) AND 2022-1523 (NEW SUGAR STORAGE - GROUND IMPROVEMENTS)). ) Original Permit Description:(COM2023-00085) SCOPE OF WORK:---NEW CONSTRUCTION----CONSTRUCT NEW SUGAR STORAGE FACILITY AS PER PLANS AS PER CODE. (ASSOCIATED WITH PRIOR PLAN# 2022-1691 (NEW SUGAR STORAGE - DEMOLITION SCOPE ONLY) AND 2022-1523 (NEW SUGAR STORAGE - GROUND IMPROVEMENTS)). | — | Nov 29, 2024 |
| COM2023 | SCOPE OF WORK:---NEW CONSTRUCTION----CONSTRUCT NEW SUGAR STORAGE FACILITY AS PER PLANS AS PER CODE. (ASSOCIATED WITH PRIOR PLAN# 2022-1691 (NEW SUGAR STORAGE - DEMOLITION SCOPE ONLY) AND 2022-1523 (NEW SUGAR STORAGE - GROUND IMPROVEMENTS)). | $10,000,000 | Aug 19, 2024 |
| COM2024 | Extend Original Permit.(original permit:COM2020-02515:CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM.) Original Permit Description:(COM2020-02515) CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM. | — | Jul 29, 2024 |
| COM2024 | INSTALL (10) # LOW VOLTAGE AS PER CODE.************* A PER THE DEPARTMENT OF PLANNING: THE STRUCTURE IS LOCATED IN THE REGULATORY FLOODPLAIN. THE FLOOD PROTECTION ELEVATION (FPE) IS 9.4 FT NAVD 88. ALL MEP COMPONENTS MUST BE LOCATED ABOVE THE FPE, BE MADE WATERTIGHT ACCORDING TO ASCE 24, OR BE ELEVATED AS MUCH AS POSSIBLE TO AVOID DAMAGE BY FLOOD WATERS. | $31,880 | Feb 8, 2024 |
| COM2023 | Extend Original Permit.(original permit:COM2020-02515:CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM.) Original Permit Description:(COM2020-02515) CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM. | — | Nov 30, 2023 |
| COM2023 | PARTIAL PERMIT SUBJECT TO ALL CONDITIONS OF AGREEMENT ON FILE FOR CONCRETE FLOATING SLAB FOUNDATION AND WALL STRUCTURE, CONCRETE FOUNDATIONS (F1, F2, AND F3) FOR AN INDUSTRIAL WAREHOUSE PENDING ACTION FOR PLAN 2023-68 THE ISSUANCE OF BUILDING PERMIT AND THE UNDERSTANDING THAT ARCHITECT/ENGINEER WILL COMPLY WITH THE BALTIMORE CITY BUILDING, FIRE AND RELATED CODES 2020. | — | Oct 19, 2023 |
| COM2023 | INSTALL FIRE ALARM DEVICES IN SUGAR SILO STRUCTURE AS PER PLANS AS PER CODE. | $73,000 | Sep 12, 2023 |
| COM2023 | INSTALL (1) 3000 KW TRANSFORMER AS PER CODE. **************PER PLANNING DEPT:THE FLOOD PROTECTION ELEVATION (FPE) FOR THE AREA IS 9.4 FEET. ALL MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS MUST BE LOCATED ABOVE THE FPE (2.4 FT ABOVE NATURAL GRADE) OR BE MADE WATER TIGHT ACCORDING TO ASCE 24.^^^^^^^^^^^^^^^^^^ | $60,000 | Sep 8, 2023 |
| COM2022 | DESIGN, INSTALL, AND TEST A NEW 6'' SCHEDULE 10 GALVANIZED ''DRY STANDPIPE'' WITH GALVANIZED FITTINGS AND COUPLINGS IN AN EXTERIOR STAIR OF A GRANULATED SUGAR SILO. A TOTAL OF 6 FIRE HOSE VALVES AND A 6''X2-WAY SIAMESE CONNECTION SHALL BE INCORPORATED IN THE DESIGN AS PER PLANS AS PER CODE. | $13,000 | Jul 26, 2023 |
| COM2022 | SCOPE OF WORK:-----PAVING---FOUNDATION WORK: GROUND IMPROVEMENT SCOPE = INSTALLATION OF RIGID INCLUSION GROUND MODIFICATION SYSTEM TO INCREASE ALLOWABLE SOIL BEARING CAPACITY IN ORDER TO SUPPORT PROPOSED RAW SUGAR WAREHOUSE FACILITY, RIGID INCLUSION GROUND MODIFICATION SYSTEM HAS BEEN DESIGNED TO LIMIT TOTAL SETTLEMENT TO LESS THAN 1 INCH AND DIFFERENTIAL SETTLEMENT TO LESS THAN 0.5 INCHES. THE AMOUNT OF PILES PROPOSED IS 908. FUTURE NEW RAW SUGAR WAREHOUSE BUILDING AREA IS 44,992 SF AS PER PLANS AS PER CODE. SEPARATE PERMIT TO BE ACQUIRED FOR FUTURE BUILDING. | $2,200,000 | Jun 14, 2023 |
| COM2023 | EXTEND ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2020-02515:CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM.) Original Permit Description:(COM2020-02515) CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM. | — | May 1, 2023 |
| COM2022 | DEMOLITION SCOPE OF WORK ONLY FOR THE REMOVAL OF THE REMAINING CONCRETE WALLS UP TO FOUNDATION LEVEL AFTER THE FIRE DESTRUCTION OF THE OLD SUGAR SHED AND PARTIAL DEMOLITION OF EXISTING CONCRETE SLAB IN PREPARATION OF FUTURE WORK (TO BE SUBMITTED ON A DIFFERENT PERMIT APPLICATION), FOUNDATION OF EXISTING WILL REMAIN UNDISTURBED, AS PER PLANS AS PER CODE. (WORK DOES NOT INCLUDE DEMOLITION OF A WHOLE BUILDING NOR ELECTRICAL, MECHANICAL, OR PLUMBING SCOPE. NO ADJOINING BUILDINGS TO EXISTING WALL REMAINING). | $184,645 | Sep 27, 2022 |
| COM2020 | CONSTRUCTION OF NEW FACILITY ACCESS ROAD AND ACCOMPANYING CONCRETE RETAINING WALL AS PER PLANS AS PER CODE. | $451,000 | Jun 22, 2021 |
| COM2021 | AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2020-02515:CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM.) Original Permit Description:(COM2020-02515) CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM. | — | May 3, 2021 |
| COM2021 | REPAIR THE DOMINO SUGARS ROOF SIGN BY REPLACING DETERIORATED STEEL LETTERING AND BORDER WITH NEWLY FABRICATED ALUMINUM LETTERING AND BORDER THAT IS IDENTICAL IN BULK, SCALE AND APPEARANCE AS PER PLANS AND AS PER CODE. LETTERS AND BORDER WILL BE ILLUMINATED WITH LED TUBING TO MATCH THE APPEARANCE OF EXISTING NEON AS PER PLANS AS PER CODE. | $2,000,000 | Apr 15, 2021 |
| COM2020 | CONSTRUCT FOUR NEW SILOS FOR THE STORAGE OF GRANULATED SUGAR, THIS WILL ALSO INCLUDE ASSOCIATED GRADING, NEW BUILDING FOUNDATIONS AND THE REPLACEMENT OF AN EXISTING TIMBER BULKHEAD WITH A NEW SHEET PILE STEEL BULKHEAD AS PER PLANS AS PER CODE. SEPARATE PERMITS REQUIRED FOR FIRE ALARM/DETECTION SYSTEMS AND STANDPIPE SYSTEM. | $8,000,000 | Feb 9, 2021 |
| COM2020 | SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: SIGN INSTALLATION, PAINT TWO MURALS ON TWO SEPARATE BUILDINGS. MURAL #1 TO BE APPROXIMATELY 20'X24'. MURAL #2 TO BE APPROXIMATELY 150'X18' PER ATTACHED PLANS AND AS PER BALTIMORE CITY CODE. *ALL WORK SHOULD BE DONE ON PRIVATE PROPERTY***** APPROVED WITH CONDITIONS PER NATURAL GRADE NEAR THE SITE IS 6 FT AND THE FLOOD PROTECTION ELEVATION (FPE) IS 9.4 FT NAVD 88. THE ELECTRICAL COMPONENTS MUST BE LOCATED ABOVE THE FPE (3.4 FT ABOVE NATURAL GRADE) OR BE MADE WATER TIGHT ACCORDING TO ASCE 24 | $18,000 | Mar 6, 2020 |
| COM2020 | Extend Original Permit.(original permit:COM2019-73861:PER PLAN:: PROPOSED WORK DOES NOT TRIGGER FLOODPLAIN REQUIREMENTS. SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: PAINTING OF LETTERING ON THE EXTERIOR WALL OF TWO STRUCTURES ON SITE: THE RAW SUGAR SHED AND THE MOLASSES TANK. ''RAW SUGAR'' LETTERING TOTALING 201.5 SQUARE FEET WILL BE PAINTED ON THE SOUTH END OF THE RAW SUGAR SHED. ''MOLASSES'' LETTERING TOTALING 92.4 SQUARE FEET TO BE PAINTED ON EAST SIDE OF THE MOLASSES TANK. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, PER SUBMITTED DRAWINGS AND PHOTO SIMULATIONS ATTACHED.) Original Permit Description:(COM2019-73861) PER PLAN:: PROPOSED WORK DOES NOT TRIGGER FLOODPLAIN REQUIREMENTS. SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: PAINTING OF LETTERING ON THE EXTERIOR WALL OF TWO STRUCTURES ON SITE: THE RAW SUGAR SHED AND THE MOLASSES TANK. ''RAW SUGAR'' LETTERING TOTALING 201.5 SQUARE FEET WILL BE PAINTED ON THE SOUTH END OF THE RAW SUGAR SHED. ''MOLASSES'' LETTERING TOTALING 92.4 SQUARE FEET TO BE PAINTED ON EAST SIDE OF THE MOLASSES TANK. ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE, PER SUBMITTED DRAWINGS AND PHOTO SIMULATIONS ATTACHED. | — | Mar 3, 2020 |
| COM2019 | scope of work:--plumbing and on site utilities--install ~300 lf of 6" dip to replace existing 6" dip that is failing onsite for fire protection. as per plans and as per code *on-site utility contractor, thomas iacoboni; license no: os0007; license expiration: 12/31/2019* | $200,000 | Oct 2, 2019 |
| COM2019 | per plan:: proposed work does not trigger floodplain requirements. scope of work: exterior alterations to include: painting of lettering on the exterior wall of two structures on site: the raw sugar shed and the molasses tank. "raw sugar" lettering totaling 201.5 square feet will be painted on the south end of the raw sugar shed. "molasses" lettering totaling 92.4 square feet to be painted on east side of the molasses tank. all work will be done according to baltimore city code, per submitted drawings and photo simulations attached. | $9,000 | Aug 27, 2019 |
| COM2019 | install (3) # branch circuits/feeders , (3) # fixtures/devices as per code. | $64,000 | Aug 4, 2019 |
| COM2017 | construct a surface sand filter and a bioswale to treat stormwater collected from certain impervious surface areas at the domino sugar baltimore facility as per plans as per code. | $330,000 | Jun 13, 2019 |
| COM2018 | installation of replacement fire alarms as per plans as per code. | $215,000 | Apr 29, 2019 |
| COM2019 | install (12) # fixtures/devices, (4) # branch circuits/feeders , (1) # branch circuits/feeders as per code. | $30,000 | Apr 9, 2019 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;