Baltimore City · 21225

4106 AUDREY AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$72,000
Land use
Residential (R)
Year built
1943
Last sale
Feb 27, 2023

This owner holds 4 Baltimore City properties (Pro feature — join the waitlist).

Assessment

OwnerCALLISTE REALTY, LLC
Land useResidential (R)
Total assessment$72,000 (cycle 2026)
Last saleFeb 27, 2023
Year built1943
ZoningR-6
Vacant

Permits

17
TypeDescriptionCostIssued
USE2022USE PREMISES AS A SINGLE FAMILY DWELLINGJan 20, 2023
COM2023INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION) AS PER CODE.$7,389Jan 11, 2023
COM2023INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP AS PER CODE.$8,500Jan 5, 2023
COM2022INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (14) # PLUMBING FIXTURES AS PER CODE.$5,000Dec 21, 2022
COM2022AMEND PERMIT: CHANGE ELECTRICAL CONTRACTOR . REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83061:INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2021-83061) INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.Dec 15, 2022
COM2022INSTALL (2) # GAS TEST, (4) 60000 BTU FUEL-BURNING EQUIP AS PER CODE.$400Nov 21, 2022
COM2022SCOPE OF WORK: ALTERATIONS TO INCLUDE: GAS TEST ONE METER, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$400Nov 8, 2022
COM2022INSTALL (1) 300 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS) AS PER CODE.$10,000Nov 1, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-73659:REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83353:INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) ORIGINAL PERMIT DESCRIPTION:(COM2021-83353) INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2022-73659) REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83353:INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-83353) INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.Oct 19, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-73661:REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83061:INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.) ORIGINAL PERMIT DESCRIPTION:(COM2021-83061) INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2022-73661) REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83061:INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2021-83061) INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.Oct 19, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83353:INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.) Original Permit Description:(COM2021-83353) INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.Aug 21, 2022
COM2022 Extend Original Permit.(original permit:COM2022-51204:INTERIOR BASEMENT LEVEL: FRAME NEW SET OF STAIRS THAT LEAD FROM 1ST FLOOR TO BASEMENT (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, FRAME ONE PARTITION WALL IN BASEMENT TO ENCLOSE BEDROOM; FRAME CLOSET IN BASEMENT BEDROOM; FRAME UTILITY CLOSET; FRAME INSIDE OF PERIMETER WALLS; EXTERIOR: REPLACE 2 WINDOWS AND 3 EXTERIOR DOORS (IN THE SAME SIZE AND LOCATION), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) ) Original Permit Description:(COM2022-51204) INTERIOR BASEMENT LEVEL: FRAME NEW SET OF STAIRS THAT LEAD FROM 1ST FLOOR TO BASEMENT (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, FRAME ONE PARTITION WALL IN BASEMENT TO ENCLOSE BEDROOM; FRAME CLOSET IN BASEMENT BEDROOM; FRAME UTILITY CLOSET; FRAME INSIDE OF PERIMETER WALLS; EXTERIOR: REPLACE 2 WINDOWS AND 3 EXTERIOR DOORS (IN THE SAME SIZE AND LOCATION), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) Jul 20, 2022
COM2022REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-83061:INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2021-83061) INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.Jul 16, 2022
COM2022INTERIOR BASEMENT LEVEL: FRAME NEW SET OF STAIRS THAT LEAD FROM 1ST FLOOR TO BASEMENT (STAIRCASE: TREAD: 9''MIN, RISE: 8 1/4''MAX AND WIDTH: 36''MIN), INSTALL STRUCTURAL INFILL AT THE STAIRCASE, FRAME ONE PARTITION WALL IN BASEMENT TO ENCLOSE BEDROOM; FRAME CLOSET IN BASEMENT BEDROOM; FRAME UTILITY CLOSET; FRAME INSIDE OF PERIMETER WALLS; EXTERIOR: REPLACE 2 WINDOWS AND 3 EXTERIOR DOORS (IN THE SAME SIZE AND LOCATION), ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN MINIMUM WIDTH OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70SQ/FT FOR ONE OCCUPANT OR 50SQ/FT PER OCCUPANT, 4. ALL BATHROOMS WILL MAINTAIN ENOUGH CLEAR FLOOR SPACE FOR CLEARANCE OF PLUMBING FIXTURES) $25,000Jan 12, 2022
COM2021EXTERIOR SCOPE: REPLACE 4 WINDOWS AND 2 EXTERIOR DOORS (SAME SIZE & LOCATION) | REPAIR FRONT DOOR TRIM INTERIOR SCOPE: REPLACE 7 INTERIOR DOORS | REPLACE FLOORING | REPAIR DOOR AND WINDOW TRIM WHERE NECESSARY | DEMO DAMAGED SECTIONS OF DRYWALL | REMOVE THE TRASH FROM INSIDE THE HOUSE | REPAIR ROOF MEMBRANE IN THE REAR OF THE HOUSE | REPAINT | TIGHTEN HANDRAILS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$30,000Nov 3, 2021
COM2021INSTALL (2) 24000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (2) 80000 BTU FUEL-BURNING EQUIP(FURNACE), (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (2) 40000 BTU FUEL-BURNING EQUIP AS PER CODE.$5,000Nov 1, 2021
COM2021INSTALL (12) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # FIXTURES/DEVICES AS PER CODE.$5,000Oct 27, 2021

Violations

1
KindCategoryStatusDate
service_requestSW-Dirty AlleyClosedJan 20, 2026