Permits

27
TypeDescriptionCostIssued
BCCMInstall compete fire alarm scope based on the BOM in the submittals • 4 – Wall-Mount, Red, Horn/Strobes • 7 – Wall-Mount, Red, Strobe • 2 – Emergency Power Off (EPO) Buttons • 2 – Addressable Relay Modules (EPO) • 1 – Addressable Monitor Module (Hood)$16,000May 21, 2026
BCCMAdd and relocate sprinkler heads as needed for new renovations$19,000Mar 18, 2026
BCCMREPLACE 4 WATER CLOSETS, 4 FLUSH VALVE, 4 LAVATORY,,4 FAUCET, 4 MIXING VALVE, 10 FLOOR SINK. 2 FLOOR DRAIN AND 2 OPENSIDE DRAIN.$10,000Mar 2, 2026
BCCMSCOPE OF WORK: ----- LEVEL II INTERIOR ALTERATIONS ------- CONVERSION OF GROUND FLOOR SUITE 1 FROM WARM SHELL TO RESTAURANT. AS PER PLANS AND AS PER CODE. Please amend this permit application to add all required licensed professionals before work can begin$760,000Jan 20, 2026
USE2023USE OF ENTIRE BUILDING; 227 APARTMENT UNITS WITH AN ATTACHED PARKING GARAGE TO COMPLIMENT 648 VEHICLES, BACKUP GENERATOR (720 GALLONS), AND ASSEMBLY/GARDEN AREA. [560 BAYVIEW BLVD]Aug 26, 2023
COM2023REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-86410:INSTALL (200) # LOW VOLTAGE AS PER CODE.) Original Permit Description:(COM2022-86410) INSTALL (200) # LOW VOLTAGE AS PER CODE.Jul 17, 2023
COM2023INSTALL 7 BUILDING MOUNTED ID SIGNS. SIGN X.A1, BAYVIEW BLVD, UPPER STORY PAINTED ID SIGN, EAST ELEV: 5'-3''H X 16'-3''W = 85 SF. SIGN X.A2, SOUTH DRIVE, UPPER STORY, EDGE LIT CHANNEL LETTERS, SOUTH ELEV: 3'H X 25'W = 76 SF. SIGN G.F-1, BAYVIEW BLVD, EAST GARAGE ENTRANCE, FACE-LIT CABINET: 2'-10''H X 27'-6''W = 79 SF. SIGN G.G-1, BAYVIEW BLVD, EAST GARAGE ENTRANCE, D/F FACE-LIT PROJECTING BLADE SIGN: 3'-8''H X 2'-10''W = 10.4 SF. SIGN X.G-1 / X.G-2, BAYVIEW BLVD, EAST RESIDENTIAL ENTRY, D/F, FACE-LIT PROJECTING ID SIGN: 8'-8''H X 3'W = 26 SF. SIGN G.F-2, NORTH DRIVE, GARAGE ENTRANCE, FACE-LIT CABINET, NORTH ELEV: 2'-10''H X 27'-6''W = 79 SF. SIGN G.G-2, NORTH DRIVE, GARAGE ENTRANCE, FACE-LIT PROJECTING BLADE SIGN, NORTH ELEV'' 3'-8''H X 2'-10''W = 10.4 SF. ALL WORK PER BALTIMORE CITY CODE AND ATTACHED PLANS. ALSO, ALL WORK IS ON PRIVATE PROPERTY.$14,500Jun 29, 2023
COM2023REINSTATE ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2022-00679:INSTALL NEW FIRE ALARM SYSTEM FOR NEW CONSTRUCTION MEDICAL OFFICE AS PER PLANS AS PER CODE.) Original Permit Description:(COM2022-00679) INSTALL NEW FIRE ALARM SYSTEM FOR NEW CONSTRUCTION MEDICAL OFFICE AS PER PLANS AS PER CODE.Feb 17, 2023
COM2022INSTALL NEW SPRINKLER SYSTEM (4,590 HEADS) AS PER PLAN AS PER CODE.$975,000Jan 13, 2023
COM2022INSTALL (200) # LOW VOLTAGE AS PER CODE.$10,000,000Nov 15, 2022
COM2022FIRE ALARM AS PER PLANS AS PER CODE.$3,000,000Oct 20, 2022
COM2022INSTALL (40) # LOW VOLTAGE AS PER CODE.$5,000,000Oct 5, 2022
COM2022AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . EXTEND ORIGINAL PERMIT.(ORIGINAL PERMIT:COM2021-00996:(THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)) Original Permit Description:(COM2021-00996) (THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)Sep 26, 2022
COM2022INSTALL (1) 600 AMPS TEMPORARY ELECTRICAL SERVICE AS PER CODE.$20,000Sep 15, 2022
COM2022INSTALL (1) TEMPORARY 800 AMPS ELECTRIC SERVICE (>600 V) AND 1 CIRCUIT AS PER CODE.$2,900Jul 28, 2022
COM2022AMEND PERMIT: ADD GAS CONTRACTOR . (ORIGINAL PERMIT:COM2020-02909:(ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.) Original Permit Description:(COM2020-02909) (ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.May 20, 2022
COM2022(WORK BEGINS AT END OF BACKFLOW PREVENTOR BY OTHER). INSTALL AUTOMATIC WET TYPE SPRINKLER SYSTEM INCLUDING (818) SPRINKLERS, (1) FIRE PUMP AND (2) STANDPIPES. LARGEST PIPE SIZE = 6'' LIGHT HAZARD, ORDINARY GROUP I AS PER PLANS AS PER CODE.$212,000May 19, 2022
COM2022INSTALL NEW FIRE ALARM SYSTEM FOR NEW CONSTRUCTION MEDICAL OFFICE AS PER PLANS AS PER CODE.$50,000Apr 12, 2022
COM2022AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2020-02909:(ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.) Original Permit Description:(COM2020-02909) (ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.Mar 8, 2022
COM2022INSTALL (1) 300 AMPS TEMPORARY ELECTRIC SERVICE (>600 V) AND (1) CIRCUIT AS PER CODE.$5,000Feb 24, 2022
COM2022AMEND PERMIT: ADD HVAC CONTRACTOR . (ORIGINAL PERMIT:COM2020-02909:(ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.) Original Permit Description:(COM2020-02909) (ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.Feb 4, 2022
COM2022AMEND PERMIT: ADD PLUMBER CONTRACTOR . (ORIGINAL PERMIT:COM2020-02909:(ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.) Original Permit Description:(COM2020-02909) (ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.Jan 31, 2022
COM2022AMEND PERMIT: ADD PLUMBER, GAS AND HVAC CONTRACTOR .(ORIGINAL PERMIT:COM2021-00996:(THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)) Original Permit Description:(COM2021-00996) (THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)Jan 7, 2022
COM2021AMEND PERMIT: ADD ELECTRICAL CONTRACTOR . (ORIGINAL PERMIT:COM2021-00996:(THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)) Original Permit Description:(COM2021-00996) (THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)Nov 4, 2021
COM2021SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: PLACEMENT OF TEMPORARY OFFICE TRAILER, PLACEMENT OF CONSTRUCTION TRAILER DURING CONSTRUCTION OF COM2020-02909, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE AND PER SUBMITTED PLANS/SPECIFICATIONS. $10,000Oct 5, 2021
COM2020(ALL SITE WORK COMPLETED UNDER APPROVED ESD#7372 / ISSUED PERMIT COM2018-01476) CONSTRUCT NEW BUILDING WITH 227 RESIDENTIAL UNITS, 5,700 SF OF GROUND FLOOR RETAIL, 10,000 SF OF AMENITY/LEASING SPACE AND 648 STRUCTURED PARKING SPACES. THE BUILDING IS A MIXTURE OF TYPE I-A, III-A, AND III-B CONSTRUCTION WHICH CONSISTS OF CONCRETE, STEEL, AND WOOD STRUCTURAL MEMBERS. THE STRUCTURED PARKING IS PRECAST CONCRETE. THE SCOPE OF WORK INCLUDES MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS FOR THE RESIDENTIAL UNITS, AMENITY, AND RETAIL SPACES AS PER PLANS AS PER CODE.$45,000,000Sep 28, 2021
COM2021(THE YARD 56 MEDICAL OFFICE BUILDING PROJECT IS PART OF THE LARGER YARD 56 PLANNED UNIT DEVELOPMENT) THE THREE STORY BUILDING WILL CONSIST OF A STEEL STRUCTURAL FRAME WITH A BRICK AND METAL PANEL SKIN, THE BUILDING IS TO BE A CORE AND SHELL CONSTRUCTION (THAT WILL BE OCCUPIED BY FUTURE TENANTS) THE CORE IS TO BE FULL FINISHED WITH THE TENANT SPACES FINISHED TO THE LEVEL OF A WARM DARK SHEL AS PER PLANS AS PER CODE. (THE SITE WAS MASS GRADED UNDER GRADING PERMIT COM2018-01476)$12,600,000Sep 13, 2021

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-11; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.