Total assessment
$546,200
Land use
Residential (R)
Year built
1920
Last sale
Jun 23, 2025

Assessment

OwnerFULLER, ROBERT
Land useResidential (R)
Total assessment$546,200 (cycle 2026)
Last saleJun 23, 2025 — $560,000
Year built1920
ZoningR-8
Vacant

Permits

9
TypeDescriptionCostIssued
USE2024TO USE AS A SINGLE FAMILY DWELLING.Dec 3, 2024
COM2024 Extend Original Permit.(original permit:COM2024-62287:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING AND NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING 2ND FLOOR REAR WALL. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4"RISER,11"TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). NEW EXTERIOR WORK: DEMO/REBUILD EXISTING 1ST FLOOR REAR ADDITION (11'X12')(132 SF) SAME SIZE & LOCATION. NEW 2ND FLOOR REAR ADDITION (11'X12') (132 SF). NEW INTERIOR STAIR TO NEW ROOFTOP DECK (11'X16'). NEW EXTERIOR DOORS (3), WINDOWS (20). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (23;-8"X14')(331 SF). AS PER PLANS, AS PER CODE. ) Original Permit Description:(COM2024-62287) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING AND NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING 2ND FLOOR REAR WALL. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4"RISER,11"TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). NEW EXTERIOR WORK: DEMO/REBUILD EXISTING 1ST FLOOR REAR ADDITION (11'X12')(132 SF) SAME SIZE & LOCATION. NEW 2ND FLOOR REAR ADDITION (11'X12') (132 SF). NEW INTERIOR STAIR TO NEW ROOFTOP DECK (11'X16'). NEW EXTERIOR DOORS (3), WINDOWS (20). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (23;-8"X14')(331 SF). AS PER PLANS, AS PER CODE. Nov 12, 2024
COM2024SCOPE OF WORK: ELECTRICAL ALTERATIONS TO INCLUDE: INSTALLATION OF 38 LIGHTS, 200AMP SERVICE, 45 RECEPTACLES,18 SWITCHES, 18 CIRCUITS, ALL WORK WILL BE DONE ACCORDING TO BALTIMORE CITY CODE$9,500Jun 24, 2024
COM2024INSTALL (1) 36000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (4) 50 CFM EXHAUST SYSTEMS , (1) 80000 BTU FUEL-BURNING EQUIP(FURNACE) AS PER CODE.$17,000Jun 5, 2024
COM2024INSTALL (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # ELECTRIC WATER HEATER, (12) # PLUMBING FIXTURES, (2) 120000 BTU FUEL-BURNING EQUIP AS PER CODE.$1,000Jun 4, 2024
COM2024REMOVE FORMSTONE,CLEAN AND REPOINT EXISTING BRICK PER BALTIMORE CITY CODE$4,200May 21, 2024
COM2024UNDERPINNING OF FOUNDATION WALLS AS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION. EXISTING BASEMENT HEIGHT = 6'-0'', PROPOSED HEIGHT = 8'-0''. NEW 4'' CONCRETE SLAB ON 4'' GRAVEL. AS PER PLANS AND AS PER CODE.$5,000May 2, 2024
COM2024INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING AND NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST FLOOR REAR ADDITION, DEMO EXISTING 2ND FLOOR REAR WALL. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,500 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). NEW EXTERIOR WORK: DEMO/REBUILD EXISTING 1ST FLOOR REAR ADDITION (11'X12')(132 SF) SAME SIZE & LOCATION. NEW 2ND FLOOR REAR ADDITION (11'X12') (132 SF). NEW INTERIOR STAIR TO NEW ROOFTOP DECK (11'X16'). NEW EXTERIOR DOORS (3), WINDOWS (20). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (23;-8''X14')(331 SF). AS PER PLANS, AS PER CODE. $80,000Apr 24, 2024
COM2024SCOPE OF WORK: ------ INTERIOR ALTERATIONS ---- TO INCLUDE: CATEGORY 1 DEMO (500 SF) OF NON-BEARING STUD WALLS, PLASTER, TRIM, INSULATION, FLOORING & DEBRIS AS PER CODE. DEMO ONLY$3,000Apr 16, 2024

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.