Baltimore City · 21224
603 GRUNDY ST
Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.
Already have Pro access? Sign in.
- Total assessment
- $443,900
- Land use
- Residential (R)
- Year built
- 1920
- Last sale
- Jan 23, 2024
Assessment
| Owner | SCHLEGEL, ERIC |
|---|---|
| Land use | Residential (R) |
| Total assessment | $443,900 (cycle 2026) |
| Last sale | Jan 23, 2024 — $495,000 |
| Year built | 1920 |
| Zoning | R-8 |
| Vacant | — |
Permits
6| Type | Description | Cost | Issued |
|---|---|---|---|
| USE2021 | USE AS A SINGLE-FAMILY DWELLING. | — | Sep 29, 2021 |
| COM2021 | Extend Original Permit.(original permit:COM2021-54635:INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,928 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). DEMO/REPOUR BASEMENT SLAB (39'X14')(546 SF), 3'' GRAVEL, 4'' SLAB. NEW EXTERIOR WORK: NEW 1ST FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 1ST FLOOR REAR DECK (12'X14'-9'') WITH STEPS TO GRADE, NEW 2ND FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 2ND FLOOR REAR BALCONY (3'X14'-9''). NEW EXTERIOR DOORS (4), WINDOWS (9). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (58'-9.5''X14'-9'') (675 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN WIDTH MINIMUM OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER OCCUPANT OR 50 SQ/FT PER OCCUPANT IF MORE THAN ONE, 4. ALL WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND WILL NOT IMPACT THE ADJOINING NEIGHBORS PROPERTY LINES) ) Original Permit Description:(COM2021-54635) INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,928 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). DEMO/REPOUR BASEMENT SLAB (39'X14')(546 SF), 3'' GRAVEL, 4'' SLAB. NEW EXTERIOR WORK: NEW 1ST FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 1ST FLOOR REAR DECK (12'X14'-9'') WITH STEPS TO GRADE, NEW 2ND FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 2ND FLOOR REAR BALCONY (3'X14'-9''). NEW EXTERIOR DOORS (4), WINDOWS (9). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (58'-9.5''X14'-9'') (675 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN WIDTH MINIMUM OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER OCCUPANT OR 50 SQ/FT PER OCCUPANT IF MORE THAN ONE, 4. ALL WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND WILL NOT IMPACT THE ADJOINING NEIGHBORS PROPERTY LINES) | — | Sep 28, 2021 |
| COM2021 | INSTALL (22) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (10) # LOW VOLTAGE AS PER CODE. | $5,000 | Jul 5, 2021 |
| COM2021 | INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY), (1) 72000 BTU FUEL-BURNING EQUIP AS PER CODE. | $4,000 | Jul 1, 2021 |
| COM2021 | INSTALL (11) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) 35000 BTU FUEL-BURNING EQUIP, (1) 75000 BTU FUEL-BURNING EQUIP AS PER CODE. | $250 | May 20, 2021 |
| COM2021 | INTERIOR WORK: CATEGORY 3 DEMO (500 SF) OF BEARING & NON-BEARING STUD WALLS, STAIRS, PLASTER, TRIM, INSULATION, FLOORING / ROOFING & DEBRIS. DEMO EXISTING 1ST & 2ND FLOOR REAR WALLS. NEW FLOOR & ROOF JOISTS AS PER PLANS. NEW INTERIOR WORK: FRAMING (1,928 SF) W/ STUD WALLS, STAIRCASE (7-3/4''RISER,11''TREAD,3'WIDE) W/ HANGERS, DRYWALL, TRIM, INSULATION (R-20 WALLS, R-49 ROOF). DOORS (18). DEMO/REPOUR BASEMENT SLAB (39'X14')(546 SF), 3'' GRAVEL, 4'' SLAB. NEW EXTERIOR WORK: NEW 1ST FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 1ST FLOOR REAR DECK (12'X14'-9'') WITH STEPS TO GRADE, NEW 2ND FLOOR REAR ADDITION (15'X14'-9'')(221.25 SF), NEW 2ND FLOOR REAR BALCONY (3'X14'-9''). NEW EXTERIOR DOORS (4), WINDOWS (9). DEMO/REPOUR EXISTING REAR CONCRETE SLAB (58'-9.5''X14'-9'') (675 SF). AS PER PLANS, AS PER CODE. (*NOTES: 1. ALL HABITABLE AREAS WILL MAINTAIN MINIMUM CEILING HEIGHT OF 7', 2. ALL HALLWAYS WILL MAINTAIN WIDTH MINIMUM OF 36'', 3. ALL BEDROOMS WILL MAINTAIN 70 SQ/FT PER OCCUPANT OR 50 SQ/FT PER OCCUPANT IF MORE THAN ONE, 4. ALL WORK WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND WILL NOT IMPACT THE ADJOINING NEIGHBORS PROPERTY LINES) | $80,000 | Mar 17, 2021 |
Violations
0No violations on record.
Inspections
0No inspections on record.
Nearby recent activity
- permit: BRCMJul 10, 2026 · 52 m · 608 GRUNDY ST
- permit: BUSEJul 8, 2026 · 100 m · 4015 EASTERN AVE
- violation: SW-Dirty AlleyJun 27, 2026 · 84 m
- violation: SW-Dirty AlleyJun 26, 2026 · 77 m · 505 GRUNDY ST
- violation: SW-Dirty AlleyJun 24, 2026 · 81 m · 503 GRUNDY ST
- violation: SW-Dirty AlleyJun 22, 2026 · 77 m · 505 GRUNDY ST
- violation: SW-Dirty AlleyJun 17, 2026 · 148 m
- violation: SW-Dirty AlleyJun 8, 2026 · 70 m
- violation: SW-Dirty AlleyJun 5, 2026 · 72 m
- permit: BRCMJun 3, 2026 · 137 m · 3913 FOSTER AVE
Records marked with * are matched by address, not a direct account link. Data is informational only.
Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;
Official sources: Maryland SDAT, Baltimore City permits.