Baltimore City · 21224

611 S EAST AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$377,300
Land use
Residential (R)
Year built
1913
Last sale
Oct 25, 2021

Assessment

OwnerWEBSTER, OLIVIA
Land useResidential (R)
Total assessment$377,300 (cycle 2026)
Last saleOct 25, 2021 — $485,000
Year built1913
ZoningR-8
Vacant

Permits

10
TypeDescriptionCostIssued
USE2021USE AS SINGLE FAMILY DWELLINGJun 7, 2021
COM2021 Extend Original Permit.(original permit:COM2020-85232:REMOVE ALL NON LOAD BEARING INTERIOR WALLS, FLOORING, FIXTURES, WINDOWS, ALL MECHANICALS, 2ND FLOOR REAR WALL. NEW BASEMENT SLAB TO HAVE 4'' GRAVEL, 4'' CONCRETE AND VAPOR BARRIER. FRAME NEW LAYOUT AS PER PLANS, ALL INTERIOR WALLS TO BE 2X4@16'' O.C., REAR EXTERIOR WALL TO BE 2X6@16'' O.C., INSTALL R49 INSULATION IN CEILING AND R21 ON EXTERIOR WALLS, INSTALL NEW DRYWALL AND TRIM, 11 INTERIOR DOORS, KITCHEN CABINETS, INSTALL (2) 16X16 FOOTINGS MIN 30'' BELOW GRADE IN REAR, INSTALL 12 EXTERIOR WINDOWS, 2 EXTERIOR DOORS, REAR CONCRETE PAD 29'-10'' X 14', 4'' GRAVEL AND 4'' CONCRETE WITH WIRE MESH, INSTALL 8X14 REAR 2ND FLOOR ADDITION. ALL WORK TO BE DONE PER PLANS AND CODE. WORK TO BE COMPLETED ON ALL FLOORS. ) Original Permit Description:(COM2020-85232) REMOVE ALL NON LOAD BEARING INTERIOR WALLS, FLOORING, FIXTURES, WINDOWS, ALL MECHANICALS, 2ND FLOOR REAR WALL. NEW BASEMENT SLAB TO HAVE 4'' GRAVEL, 4'' CONCRETE AND VAPOR BARRIER. FRAME NEW LAYOUT AS PER PLANS, ALL INTERIOR WALLS TO BE 2X4@16'' O.C., REAR EXTERIOR WALL TO BE 2X6@16'' O.C., INSTALL R49 INSULATION IN CEILING AND R21 ON EXTERIOR WALLS, INSTALL NEW DRYWALL AND TRIM, 11 INTERIOR DOORS, KITCHEN CABINETS, INSTALL (2) 16X16 FOOTINGS MIN 30'' BELOW GRADE IN REAR, INSTALL 12 EXTERIOR WINDOWS, 2 EXTERIOR DOORS, REAR CONCRETE PAD 29'-10'' X 14', 4'' GRAVEL AND 4'' CONCRETE WITH WIRE MESH, INSTALL 8X14 REAR 2ND FLOOR ADDITION. ALL WORK TO BE DONE PER PLANS AND CODE. WORK TO BE COMPLETED ON ALL FLOORS. Jun 3, 2021
COM2021SCOPE OF WORK: EXTERIOR ALTERATIONS TO INCLUDE: DECK AND STAIRCASE CONSTRUCTION, CONSTRUCT A 14'X14' ROOF DECK WITH STAIR ACCESS, STAIRS TO BE 36'' WIDE, 11'' TREAD AND 7.75 RISE. ALL WORK AS PER PLANS AND CODE. (*NOTE: 1. ALL DECK AND STAIRCASE WILL BE DONE WITHIN PRIVATE PROPERTY LINES AND MAINTAIN PROPER SETBACKS, 2. DECK WILL BE SECURED TO PROPERTY, STRUCTURALLY AND SAFELY) $5,000Apr 20, 2021
COM2021INSTALL (16) # BRANCH CIRCUITS/FEEDERS , (1) 200 AMPS ELECTRIC SERVICE UP TO 600V (#AMPS), (12) # LOW VOLTAGE AS PER CODE.$8,000Feb 12, 2021
COM2021REMOVE FORMSTONE, CLEAN AND REPOINT EXISTING BRICK PER BALTIMORE CITY CODE$2,800Feb 11, 2021
COM2021INSTALL (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.$2,000Feb 9, 2021
COM2021INSTALL (1) 30 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 60 BTU FUEL-BURNING EQUIP(FURNACE), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$7,000Jan 29, 2021
COM2021INSTALL (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE (RECONSTRUCTION), (12) # PLUMBING FIXTURES, (1) # ELECTRIC WATER HEATER, (1) 60000 BTU FUEL-BURNING EQUIP, (1) 48000 BTU FUEL-BURNING EQUIP AS PER CODE.$8,000Jan 6, 2021
COM2020SCOPE OF WORK: INTERIOR ALTERATIONS TO INCLUDE: UNDERPINNING OF EXISTING BASEMENT AREAS 30’-6”X 12'-9''. EXISTING BASEMENT HEIGHT IS 5'-5'' AND NEW HEIGHT SHALL BE 7'-1''. ''UNDERPINNING OF FOUNDATION WALLS PER ATTACHED ENGINEER'S PLANS AND CERTIFICATION. THE ENGINEER CERTIFICATION IS REQUIRED AT COMPLETION OF WORK AND WITH A REPORT OF THE EXACT DATES OF PERIODIC INSPECTIONS DURING THE CONSTRUCTION'' ALL WORK SHALL BE IN ACCORDANCE WITH BALTIMORE CITY BUILDING CODES AND PER SUBMITTED PLANS.$7,500Dec 18, 2020
COM2020REMOVE ALL NON LOAD BEARING INTERIOR WALLS, FLOORING, FIXTURES, WINDOWS, ALL MECHANICALS, 2ND FLOOR REAR WALL. NEW BASEMENT SLAB TO HAVE 4'' GRAVEL, 4'' CONCRETE AND VAPOR BARRIER. FRAME NEW LAYOUT AS PER PLANS, ALL INTERIOR WALLS TO BE 2X4@16'' O.C., REAR EXTERIOR WALL TO BE 2X6@16'' O.C., INSTALL R49 INSULATION IN CEILING AND R21 ON EXTERIOR WALLS, INSTALL NEW DRYWALL AND TRIM, 11 INTERIOR DOORS, KITCHEN CABINETS, INSTALL (2) 16X16 FOOTINGS MIN 30'' BELOW GRADE IN REAR, INSTALL 12 EXTERIOR WINDOWS, 2 EXTERIOR DOORS, REAR CONCRETE PAD 29'-10'' X 14', 4'' GRAVEL AND 4'' CONCRETE WITH WIRE MESH, INSTALL 8X14 REAR 2ND FLOOR ADDITION. ALL WORK TO BE DONE PER PLANS AND CODE. WORK TO BE COMPLETED ON ALL FLOORS. $52,000Nov 30, 2020

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.