Baltimore City · 21206

5901 MARLUTH AVE

Property watching is a Pro feature. Join the waitlist to get new permits, violations, and inspections on this property in a daily email digest.

Total assessment
$288,833
Land use
Residential (R)
Year built
1900
Last sale
Jul 9, 2021

Assessment

OwnerLAMBROS, DAVID
Land useResidential (R)
Total assessment$288,833 (cycle 2026)
Last saleJul 9, 2021 — $279,000
Year built1900
ZoningR-3
Vacant

Permits

7
TypeDescriptionCostIssued
USE2021USE AS A SINGLE-FAMILY DWELLING. Feb 3, 2021
COM2020 Extend Original Permit.(original permit:COM2020-65763:INSTALL (3) # BRANCH CIRCUITS/FEEDERS , (51) # FIXTURES/DEVICES AS PER CODE.) Original Permit Description:(COM2020-65763) INSTALL (3) # BRANCH CIRCUITS/FEEDERS , (51) # FIXTURES/DEVICES AS PER CODE.Dec 21, 2020
COM2020 Extend Original Permit.(original permit:COM2020-66289:INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 70000 BTU FUEL-BURNING EQUIP(FURNACE), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.) Original Permit Description:(COM2020-66289) INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 70000 BTU FUEL-BURNING EQUIP(FURNACE), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.Dec 7, 2020
COM2020 LOAD BEARING BEAM SEPARATING KITCHEN FROM LIVING ROOM AREA INSTALLED • 2 – 2”X14” LAMINATED BEAMS TO BE INSTALL WHERE OLD KITCHEN WALL THAT SEPARATES KITCHEN FROM LIVING ROOM ARE TO BE INSTALLED • BEAMS ARE TO BE SCREWED TOGETHER WITH SCREWS AND RESTING ON 6X6 TIMBERS ON EACH END APPROX. 14’ IN LENGTH • 6X6 TIMBERS ARE TO REST ON TOP OF EXISTING HOUSE CONCRETE FOUNDATION WALLS BELOW AND SECURED TO EXISTING WALLS IN THE KITCHEN AREA, DINING ROOM AREA STRUCTURAL REPAIR • APPROX. 8 – 2X8X14 ARE TO BE SISTERED TO EXISTING CEILING LUMBER FOR ADDITIONAL SUPPORT. THE OLD OWNER HAD REMOVED A WALL AND ONLY AN OLD POST WAS HOLDING THE EXISTING LUMBER UP. • NEW 2X8X14 LUMBER WILL BE SECURED TO EXISTING FLOOR JOISTS ABOVE WITH ½ INCH CARRIAGE BOLTS, NUTS AND WASHERS IN A STAGGERED PATTERN ALONG EACH FLOOR JOIST FOR ADDITIONAL SUPPORT • A DOUBLE TOP PLATED WALL IS TO BE BUILT FOR ADDITIONAL SUPPORT FOR THE FRONT WALL OF A UTILITY ROOM AREA. 2X8’S WILL ALSO SIT ON TOP OF THIS WALL ALONG THE RUN TO EACH END THAT IS A STRUCTURAL EXISTING WALL • METAL BRACKETS ARE TO BE INSTALLED FOR ADDITIONAL SUPPORT AND SCREWED TO EXISTING EXTERIOR WALLS, NON-STRUCTURAL FRAMING EXISTING 1ST FLOOR ROOM ON RIGHT SIDE OF STAIRWAY • FRAME A SMALL POWDER ROOM IN AN EXISTING ROOM APPROX. 5’X5’ TO CREATE A POWDER ROOM • FRAME AROUND A DUCT RUN IN THE CORNER CEILING OF THIS SAME ROOM TO ENCLOSE HVSAC DUCT • FRAME ENTRANCE DOOR WAY TO POWDER ROOM UTILITY ROOM 1ST FLOOR OF OF DINING ROOM • FRAME WALL TO ENCLOSE HVAC SYSTEM AND DUCT RUN IN SAME AREA TO ENCLOSE A 4”X8” DUCT AND LINE SET 2ND FLOOR FRAMING • FRAME A NEW MASTER BEDROOM AREA DOORWAY APPROX.. 6’, AS PER CODE/SKETCH$1,500Aug 28, 2020
COM2020INSTALL (12) # PLUMBING FIXTURES, (1) # SANITARY CONNECTION (RECONSTRUCTION0, (1) # WATER SERVICE PIPE, NEW INTERIOR, (3) 150 BTU FUEL-BURNING EQUIP AS PER CODE.$1,750Jul 13, 2020
COM2020INSTALL (1) 30000 BTU AIR-CON SYSTEM, HEAT PUMP, (1) 70000 BTU FUEL-BURNING EQUIP(FURNACE), (1) # NEW DISTRIBUTION SYSTEM (1-2 FAMILY) AS PER CODE.$7,000Jun 2, 2020
COM2020INSTALL (3) # BRANCH CIRCUITS/FEEDERS , (51) # FIXTURES/DEVICES AS PER CODE.$1,000May 27, 2020

Violations

0

No violations on record.

Inspections

0

No inspections on record.

Nearby recent activity

Records marked with * are matched by address, not a direct account link. Data is informational only.

Data freshness: city-311: 2026-07-12; city-ecb-citations: 2026-07-12; city-housing-inspections: 2026-07-12; city-permits: 2026-07-12; city-real-property: 2026-07-12; city-vbn: 2026-07-12; county-permits: 2026-07-12; sdat-properties: 2026-07-12;

Official sources: Maryland SDAT, Baltimore City permits.